The internal disturbances of the PLC system are mainly caused by the mutual electromagnetic radiation between the internal components and circuits of the system, such as the mutual radiation of logic circuits and their influence on the imitation circuit, the interaction between imitation and logic, and the mutual mismatch between components. How to effectively deal with the internal annoyance of PLC long-distance module system?

                              Internal interference in PLC remote module system - Xinjie

The tolerance of logical voltage disturbance in PLC operation is low, and the distribution disturbance of logical ground potential minimally affects the logic operation and data storage of PLC, resulting in data disorder, program running or crashing. Imitation of the distribution of ground potential will lead to the decrease of measurement accuracy, resulting in severe distortion and malfunction of signal measurement and control. PLC module manufacturers generally carry out electromagnetic compatibility design content inside the system, which is more messy than **, as the application part can not be changed, but there is no need to think too much, but how to better and more briefly deal with the troubles of PLC system?

1. Correct grounding, which can not only press the influence of electromagnetic disturbances, but also press the equipment to announce the disturbances;

2. Choose equipment with good blocking function, excellent power supply, power line and signal line routing should be more reasonable, etc., and press the common grounding, inverter, solenoid valve and unknown pulse to disturb the equipment; Together with the function of voltage limiting and frontal current for subordinate equipment, it is the faithful protection of transmitters, appearances, inverters, solenoid valves, PLC/DCS input and output and communication interfaces.

More on that
PLC installation precautions - Xinjie PLC installation precautions - Xinjie

Of course, PLC control is much more reliable than relay control, but if the device does not meet the requirements, it will not work. Therefore, the PLC machine should be installed correctly outside. (1) Pay attention to the environment of the installation The temperature should not be lower than 0°C and above 55°C, for example, not installed by a large stove, and ...

Explanation of some common fields of inverter - Xinjie inverter Explanation of some common fields of inverter - Xinjie inverter

1. The inverter is used in the air conditioning load class Office buildings, shopping malls and some supermarkets and factories have central air conditioning, and the electricity consumption of air conditioning is very large at the peak of electricity consumption in summer. In the hot climate, Beijing, Shanghai, Shenzhen air conditioning ...

Interference within the PLC remote module system - Xinjie PLC Interference within the PLC remote module system - Xinjie PLC

The internal disturbance of the PLC system is mainly caused by the mutual electromagnetic radiation between the components and circuits inside the system, such as the mutual radiation of logic circuits and their influence on the imitation circuit, the interaction between the imitation ground and the logical ground and the mutual mismatch between components. How to deal with PLC long distances effectively ...

Characteristics and composition of Xinjie tile programming system Characteristics and composition of Xinjie tile programming system

Tile programming features The editing and display mode in all Chinese greatly improves the readability of the program; Customizable programming instructions. Not only can the name of the instruction be modified according to the characteristics of the industry, but also the instruction can be added or deleted according to the needs of the equipment; Adopt a procedural editing mode. ...

New models such as IoT industrial controllers and smart cameras have been launched New models such as IoT industrial controllers and smart cameras have been launched

From 14:00 to 15:20 on May 14 last year, the X-SIGHT visual brand conference with the theme of "Vision, Light Up Intelligent Manufacturing" was held online, officially announcing that Wuxi Xinjie and Intel will join hands to create a new era of intelligent manufacturing. X-SIGHT unveiled a new Intel chip-based ...

Common models of Xinjie PLC and their characteristics Common models of Xinjie PLC and their characteristics

Model introduction of Xinjie PLC   XC series Including XC1 (economy), XC2 (basic), XC3 (standard), XC5 (enhanced), XCM (sport), XCC (high-performance) and their corresponding expansion modules, as well as special analog bodies and other special models. XC series PLC can be ...

Xinjie MS6 series high-performance servo motor is pleased to mention the 2020 "Automation Innovation Award - Motion Control Category" Xinjie MS6 series high-performance servo motor is pleased to mention the 2020 "Automation Innovation Award - Motion Control Category"

On March 19, 2021, the "Made in China Digital Service Summit 2021 CAIMRS and Annual Selection and Award Ceremony" held by China's industrial control network was broadcast live on the cloud of the "Industrial Control Network Digital Conference Hall". At the meeting, Pan Yingzhang, President of Gongkong®, officially released China's automation and digital ...

The reason for the abnormal alarm in PLC - Xinjie The reason for the abnormal alarm in PLC - Xinjie

With the continuous development of industrial automation, PLC is widely used in industrial control professions. No matter how strong the PLC product is, it often fails to work normally. All kinds of brands of PLC have the function of self-diagnosis, but the skill of PLC repair is that when the PLC is abnormal, the function should be fully used.

Analysis of problems encountered by Xinjie PLC Analysis of problems encountered by Xinjie PLC

Xinjie PLC丨The condition is established, why is the corresponding coil not in place? There are two possible reasons for this: (1) The same coil may be used in multiple places to perform the double coil output, and the coil on the rear side will operate first when the double coil is output. (2 ...

Xinjie in a nutshell! Xinjie in a nutshell!

As the only domestic brand among the top 10 small PLC shopping malls in China, Xinjie has broken through the core shopping malls dominated by international brands for more than ten years, and the unswerving commitment of the leader Li Xin to independent development can be seen. ...

Why does the industry use PLC without single-chip microcomputer-Xinjie Why does the industry use PLC without single-chip microcomputer-Xinjie

First, let's talk about PLC first About PLC, don't just see the PLC module, but a variety of PLC modules + host computer channel software to form a well-structured control systemPLC module is composed of microprocessor + memory + firmware + programming to complete the modular function. PLC control system ...

The characteristics of the inverter in the process of development - Xinjie The characteristics of the inverter in the process of development - Xinjie

The frequency converter is a power converter in the motion control system. Today's motion control system includes many technical fields, and the general development trend is: communication drive, high-frequency power changer, digital, intelligent, and networked control. VFDs are power converters in motion control systems. ...

Introduction to PLC debugging steps - Xinjie Introduction to PLC debugging steps - Xinjie

Input and output loop debugging 1. Analog input (AI) loop debugging. Carefully check the address assignment of the I0 module; Check whether the loop power supply mode (internal power supply or external power supply) is consistent with the field instrument; Use a signal generator to add a signal to each channel at the field end, generally taking 0, 5 ...

Xinjie launched a new product - I2C intelligent industrial controller Xinjie launched a new product - I2C intelligent industrial controller

On April 21, with the theme of "I2C More Intelligent Industrial Control", the new product launch and brand promotion conference of Xinjie Intelligent Control was successfully held at Gusu Shangri-La Hotel. At the meeting, in addition to the release of new products, it also discussed the connotation of intelligent industrial control, application scenarios, and the outlook of shopping malls.

Xinjie released MS6 series B3 motors Xinjie released MS6 series B3 motors

Since the advent of the MS6 series B1 and B2 servo motors, they have been widely recognized by customers for their outstanding performance advantages, and their performance in terms of temperature rise, overload ability, overspeed range and protection level is far better than that of MS5 series servo motors. This MS6 series B3 motor released will ...

Attention to the solution of heat dissipation in the application of inverter - Xinjie Attention to the solution of heat dissipation in the application of inverter - Xinjie

Assuming that the inverter has a long service life, heat dissipation must be carefully considered. Because the equipment failure rate of the inverter increases exponentially with the increase of temperature, the service life decreases. If the operating temperature rises by 10 degrees, the service life of the inverter will decrease. ...

The development status of human-computer interface shopping malls in China The development status of human-computer interface shopping malls in China

The development status of human-computer interface shopping malls in China China is the shopping mall with the largest demand for human-computer interface in the world, but it is not the shopping mall with the highest sales of human-computer interface products in the world.

Xinjie PLC problems and solutions Xinjie PLC problems and solutions

Xinjie PLC 丨Communication failure is generally summarized as the following problems: (1) Communication parameters: The communication parameters of Xinjie PLC communication port and peripheral equipment may be inconsistent. (2) Communication line: The connection may be incorrect, or the contact is poor, the user can replace the communication line and try again.

Xinjie plc programming software XCPPro Xinjie plc programming software XCPPro

XCPPro is a professional XCPPl programming software, which is a new XC series PLC programming software, which can be used normally by making corresponding configurations in XCPPro. The software supports WindowsXP32-bit Win764-bit system. ...

The steps of the system put into operation after PLC overhaul - Xinjie The steps of the system put into operation after PLC overhaul - Xinjie

After overhauling and confirming that all connections of the system are correct, power on the relevant modules until the card indicator shows normal. The initiation process of the system after the scheduled repair is as follows: (1) Power supply. Turn on the power supply equipment (including the UPS...)

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top