Xinjie PLC problems and solutions

Create Date: 2024-8-30 12:03:23|Source: XINJE

Xinjie PLC 丨Communication failure is generally summarized as the following problems:

(1) Communication parameters: The communication parameters of Xinjie PLC communication port and peripheral equipment may be inconsistent.

(2) Communication cable: The connection may be incorrect, or the contact is poor, the user can replace the communication cable and try again.

(3) Communication serial port: to view the communication serial port, you can view it by downloading the Xinjie PLC program, and if the download is successful, the serial port problem will be eliminated.

                            Xinjie PLC problems and solutions

Xinjie PLC丨The condition is established, why is the corresponding coil not in place? There are two possible reasons for this:

(1) The same coil may be used in multiple places to perform the double coil output, and the coil on the rear side will operate first when the double coil is output.

(2) At this moment, the reset condition of the coil is also established. The user can find the reset point and modify the program through the monitoring function.

More on that
Application of PLC programming in CNC maintenance - Xinjie Application of PLC programming in CNC maintenance - Xinjie

CNC machine tool is the abbreviation of digital control machine tool, which is an automatic machine tool equipped with a program control system. The control system is the numerical control system, the numerical control system can logically process the program with the control code or other symbolic instruction rules, and decode it, so that the machine tool action and add ...

Advantages of Xinjie touch screen and PLC wireless measurement and control network solution Advantages of Xinjie touch screen and PLC wireless measurement and control network solution

1. Save the transformation cycle, no need for large-scale construction: eliminate the trouble of wiring maintenance, and easily complete the transformation within one day and meet the requirements of communication stability. 2. The device is simple, no programming is required: the wireless communication terminal only needs to ...

The constituent department of PLC control cabinet - Xinjie PLc The constituent department of PLC control cabinet - Xinjie PLc

1. Air opening: a total air switch, which is the power control of the entire cabinet. I believe that every cabinet must have one thing. 2. PLC: This should be selected according to the needs of the project. For example, if the project is small, it can be an integrated PLC, but if the project is more ...

The characteristics of the inverter in the process of development - Xinjie The characteristics of the inverter in the process of development - Xinjie

The frequency converter is a power converter in the motion control system. Today's motion control system includes many technical fields, and the general development trend is: communication drive, high-frequency power changer, digital, intelligent, and networked control. VFDs are power converters in motion control systems. ...

The application of Xinjie PLC in central air conditioning The application of Xinjie PLC in central air conditioning

One. How the system works The fresh air blown in by the fresh fan enters the room through the heating exchanger, refrigeration exchanger, and humidifier. In the room, the signals measured by the temperature, humidity, and differential pressure detectors are reflected to the controller. The heating and refrigeration exchanger is controlled by a digital manipulator by a reaction signal ...

Precautions for resetting parameters of inverter - Xinjie Precautions for resetting parameters of inverter - Xinjie

(1) There is no need to adjust the parameters, we can maintain the original parameters (default value) when the inverter leaves the factory. (2) It is the parameter that needs to be set and changed before the trial operation. (3) It is a parameter that is adjusted in the operation of the demand. Frequency converters ...

Introduction to the characteristics of Xinjie frequency conversion speed regulation Introduction to the characteristics of Xinjie frequency conversion speed regulation

1. The speed regulation power is high, which is an efficient speed regulation method. This is because after the frequency change, the motor is still working in close proximity to the synchronous speed, and the rated slip is fundamentally adhered to. It's just that in the frequency conversion equipment system, there will be conversion loss, and because of the influence of higher harmonics, the loss of the motor will increase.

Characteristics and composition of Xinjie tile programming system Characteristics and composition of Xinjie tile programming system

Tile programming features The editing and display mode in all Chinese greatly improves the readability of the program; Customizable programming instructions. Not only can the name of the instruction be modified according to the characteristics of the industry, but also the instruction can be added or deleted according to the needs of the equipment; Adopt a procedural editing mode. ...

Common faults of wires and cables - Xinjie Common faults of wires and cables - Xinjie

The most direct cause of cable problems is the breakdown due to the loss of insulation. First of all, there are: a. Overload operation. Long-term overload operation will increase the temperature of the cable, aging the insulation, resulting in breakdown of insulation and degradation of construction quality. b. Electrical: the construction process of the cable head does not meet the requirements.

PLC programming algorithm - Xinjie PLC PLC programming algorithm - Xinjie PLC

1. The switching quantity is also called the logical quantity, which means that there are only two values, 0 or 1, ON or OFF. It is the most commonly used control, and it is the advantage of PLC to control it, and it is also the most basic use of PLC. The intention of switching quantity manipulation is to use the current input combination of the switching quantity with the historical input ...

Inverter protection and display function - Xinjie Inverter protection and display function - Xinjie

1. Maintenance of the inverter itself: Instantaneous overcurrent, overvoltage, undervoltage, overload, short circuit to ground, abnormal control circuit, then for the maintenance of the inverter itself, the overcurrent, overvoltage, undervoltage and so on set the limit value, when the inverter is running, if ...

The difference between the models of Xinjie TG series touch screen The difference between the models of Xinjie TG series touch screen

The suffix is XT and only supports RS232 communication, 4 inches out. The suffix MT supports RS 232/485/422 communication. The suffix is UT on the basis of MT, and a U disk port is added, which can be used to import and export engineering and CSV data from U disk. The suffix is named ET and is added to the UT ...

Troubleshooting methods for unsuccessful touch screen penetration Troubleshooting methods for unsuccessful touch screen penetration

A:a. Now only the TGM series touchscreen supports penetration as well as network connectivity b. At present, the penetration function only supports the PLC class of Xinjie that supports the Xnet protocol, and other models do not support it temporarily c. Check whether the computer has the latest version of config installed serial port equipment tool (soft ...

Quick steps to debug the inverter – Xinjie Quick steps to debug the inverter – Xinjie

1. Check the full-load power supply of the inverter (Variable-frequency Drive (VFD). 1. Ground the terminal strip of the VFD. 2. Type the switching power supply of VFD into the terminal and receive it from the switching power supply through the power switch of the leakage protector. 3. ...

Learn PLC programming skills - Xinjie PLC Learn PLC programming skills - Xinjie PLC

1. When the PLC and the host computer (or touch screen) form a monitoring system, there are many times on the screen that there are "manual", "active" and other control modes (generally more than one). In the program, you can use the "MOV" command. For example, when selecting "manual", the constant 1MOV will be ...

VFD Configure Braking Resistor step VFD Configure Braking Resistor step

Confirm the rated power and resistance value of the braking resistor. The rated power of the braking resistor should be determined according to the power and moment of inertia of the motor, and the resistance value should be selected according to the specifications of the VFD. In the VFD's parameter settings, find the parameters related to the braking resistor, such as the braking resistor selection ...

PLC and inverter shielded wire connection method - Xinjie PLC and inverter shielded wire connection method - Xinjie

In order to prevent the control signal line between the PLC and the inverter from being disturbed by the space electromagnetic field, the outer layer of these control signal lines can be connected with shielded wires to improve the anti-interference ability of the system. This kind of wiring must be noted, and only one point can be selected for the shielded connection address. Whether it's on the PLC side, or ...

Xinjie WIFI wireless communication module W-BOX Xinjie WIFI wireless communication module W-BOX

W-BOX is a 2.4GHzWifi-based wireless communication module independently developed and recently launched by Xinjie in line with the trend of wireless communication. W-BOX can be connected with wireless AP (hotspot) in various occasions to complete long-distance monitoring of PLC and overall control of PLC wireless networking in various environments.

The solution to the overcurrent of the inverter - Xinjie The solution to the overcurrent of the inverter - Xinjie

1. On the premise of satisfying the production equipment and process requirements, the acceleration or deceleration time should be increased as much as possible, and then the overcurrent generation in the process of acceleration or deceleration can be avoided. 2. Check whether the inverter, motor, and production equipment are well matched, whether the transmission part is sensitive, and whether the material is ...

Xinjie part of the XD series PLC Xinjie part of the XD series PLC

XDM Series Sport Control (Control Points: 24/32/48/60) Support basic motion control instructions, can realize two-axis linkage, interpolation, follow-up and other functions, can achieve 4-axis independent pulse output, ** multi-support 10-axis pulse output, together to support almost all of the standard PLC...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top