Tile programming features
The editing and display mode in all Chinese greatly improves the readability of the program;
Customizable programming instructions. Not only can the name of the instruction be modified according to the characteristics of the industry, but also the instruction can be added or deleted according to the needs of the equipment;
Adopt a procedural editing mode. Programming is fast and clear;
Higher safety and reliability. The configuration of system parameters such as mechanical parameters and safety parameters ensures the stable operation of the equipment from the system level;
Powerful program storage features. A single system body can store 20 different programs, and supports U disk storage and reading functions;
Wider industry applicability. With flexible instruction definition functions, it can meet the special needs of most industries;
The X-NET communication protocol is used to improve the data transmission efficiency of the system.
Composition of tile programming
Hardware:
XDC, XDM series programmable controllers;
TG, TN series true color touch screen, Xinjie teaching pendant.
Software:
PC-side tile programming software;
XDPPro editing tools;
TouchWin editing tools.
Communications:
Xinjie X-NET bus communication
|
More on that
|
Advantages of using motor soft starter - Xinjie
The motor soft starter is a new type of starting equipment designed and produced by using power electronics skills, microprocessing skills and modern control theory.
The motor soft starter can effectively limit the starting current of the AC asynchronous motor when starting, and can be widely used in wind ...
|
|
Introduction to PLC debugging steps - Xinjie
Input and output loop debugging
1. Analog input (AI) loop debugging. Carefully check the address assignment of the I0 module; Check whether the loop power supply mode (internal power supply or external power supply) is consistent with the field instrument; Use a signal generator to add a signal to each channel at the field end, generally taking 0, 5 ...
|
|
PLC programming algorithm - Xinjie PLC
1. The switching quantity is also called the logical quantity, which means that there are only two values, 0 or 1, ON or OFF. It is the most commonly used control, and it is the advantage of PLC to control it, and it is also the most basic use of PLC.
The intention of switching quantity manipulation is to use the current input combination of the switching quantity with the historical input ...
|
|
Xinjie launched a new product - I2C intelligent industrial controller
On April 21, with the theme of "I2C More Intelligent Industrial Control", the new product launch and brand promotion conference of Xinjie Intelligent Control was successfully held at Gusu Shangri-La Hotel. At the meeting, in addition to the release of new products, it also discussed the connotation of intelligent industrial control, application scenarios, and the outlook of shopping malls.
|
|
Advantages of Xinjie XDM series motion control PLC
Xinjie XDM series PLC, XDM is the sports control PLC in the XD series, now has the following types: XDM-24T4-E/C, XDM-32T4-E/C, XDM-60T4-E/C, XDM-60T10-E/C.
The XDM series has the following ...
|
|
The Xinjie touch screen screen production system includes the project
The creation of the touch screen screen is done by TouchWin editing tool software. Each screen includes each control menu and video window, and the home page can be written by the relevant units to write the advertising screen welcome speech or system model description. The system mainly includes the following items:
...
|
|
Xinjie released MS6 series B3 motors
Since the advent of the MS6 series B1 and B2 servo motors, they have been widely recognized by customers for their outstanding performance advantages, and their performance in terms of temperature rise, overload ability, overspeed range and protection level is far better than that of MS5 series servo motors.
This MS6 series B3 motor released will ...
|
|
Inverter interference mode and treatment method - Xinjie
Communication:
(1) Radiation disturbance;
(2) Conduction disturbance
Anti-disturbing method: Regarding the disturbance signal transmitted by the radiation method, it is mainly weakened by wiring and shielding the radioactive source and the disturbed line. With regard to the disturbance signal transmitted through the line, ...
|
|
Fault distribution of PLC control system - Xinjie
In order to shorten the early problem period, further extend the random problem period, and postpone the arrival of the wear and tear problem period, we will generally choose the method to take a certain approach at the beginning of the system planning.
|
|
Xinjie developed professional solutions for sealing lines
Introduction to the glass sealing industry
As a relatively old industry, the vitality of the glass industry has further burst out in the modern society, due to the social development and the improvement of people's aesthetics, the demand for glass in all walks of life is also increasing, which is also more abundant.
|
|
Troubleshooting methods for unsuccessful touch screen penetration
A:a. Now only the TGM series touchscreen supports penetration as well as network connectivity
b. At present, the penetration function only supports the PLC class of Xinjie that supports the Xnet protocol, and other models do not support it temporarily
c. Check whether the computer has the latest version of config installed serial port equipment tool (soft ...
|
|
The difference between the models of Xinjie TG series touch screen
The suffix is XT and only supports RS232 communication, 4 inches out.
The suffix MT supports RS 232/485/422 communication.
The suffix is UT on the basis of MT, and a U disk port is added, which can be used to import and export engineering and CSV data from U disk.
The suffix is named ET and is added to the UT ...
|
|
Superheat treatment method of Xinjie inverter drive motor
Why does the motor driven by the inverter overheat? This is due to the fact that the voltage of the inverter drive motor contains a rich high-frequency component.
The voltage waveform of the inverter-driven motor is not a sine wave voltage, but a pulse-width modulation (PWM) voltage. According to Fu Liye's analysis, this waveform ...
|
|
On the importance of PLC programming experience
The relevant PLC Fadu Imagination Theory is primary. Without theoretical preparation or allocation in this area, it is easy to deal with brief questions by simply inquiring in practice. It's not easy to mess up. Not only did I have no idea where to start, but it took a lot of time and energy, and it was difficult to compile a high-power, high-quality ...
|
|
The application field of PLC - Xinjie
At present, PLC has been widely used in various industries such as steel, petroleum, chemical industry, electric power, building materials, machinery manufacturing, cars, textile, transportation, environmental protection and culture and entertainment at home and abroad.
1 ...
|
|
Xinjie six-station stator internal winding system solution
As one of the important equipment for manufacturing motors, the six-station high-speed inner winding machine is widely used in electric fans, range hoods, purifiers, automobiles and other occupations. Now there are single station, double station, four station and six station winding machine types, and the six-station inner winding machine launched by Xinjie can reach up to 1200 times/i ...
|
|
Introduction to the characteristics of Xinjie frequency conversion speed regulation
1. The speed regulation power is high, which is an efficient speed regulation method. This is because after the frequency change, the motor is still working in close proximity to the synchronous speed, and the rated slip is fundamentally adhered to. It's just that in the frequency conversion equipment system, there will be conversion loss, and because of the influence of higher harmonics, the loss of the motor will increase.
|
|
The operation and use of the physical environment of the inverter - Xinjie
1. Operating temperature. The inverter is a high-power electronic component, which is easily affected by the operating temperature, and the product is generally required to be 0-55 °C, but in order to ensure the safety and reliability of the operation, it should be considered to leave room for use, and it is best to control it below 40 °C. In the control box, the inverter ...
|
|
PLC and inverter shielded wire connection method - Xinjie
In order to prevent the control signal line between the PLC and the inverter from being disturbed by the space electromagnetic field, the outer layer of these control signal lines can be connected with shielded wires to improve the anti-interference ability of the system. This kind of wiring must be noted, and only one point can be selected for the shielded connection address. Whether it's on the PLC side, or ...
|
|
The safety standard of the inverter - Xinjie
World electrical safety standards: The requirements are in line with the world's electrical safety standards, such as the CE standard in Europe and the UL standard in the United States. These specifications specify the requirements for electrical safety functions, mechanical safety functions, EMC functions, etc.
Machine...
|
|