Xinjie plc programming software XCPPro

Create Date: 2024-8-30 12:03:23|Source: XINJE

XCPPro is a professional XCPPl programming software, which is a new XC series PLC programming software, which can be used normally by making corresponding configurations in XCPPro. The software supports WindowsXP32-bit Win764-bit system.
Xinjie plc programming software XCPPro

Its main features are:

Annotation features:

In cases where the user's program is too complex and lengthy, it is often necessary to comment on the program or the software used to facilitate later modification of the program, and appropriate comments can speed up the user's understanding of the program.

Offset Function:

Indirect address searches can be achieved by adding offset suffixes (e.g., X3 [D100], M10 [D100], and D0 [D100]) to the coils and data registers. If D100=9, X3 [D100] means X14, M10 [D100] means M19, and D0 [D100] means D9.

Abundant basic functions:

The XC series programmable controllers provide users with enough basic instructions to meet the functions of basic sequence control, data transmission and comparison, four operations, logic control, data looping and displacement. The XC series programmable controller also has interrupt, high-speed counter special comparison instructions, high-speed pulse output instructions, frequency measurement, accurate timing, PID control, positioning control and other instructions.

C language editing function blocks:

The XC Series programmable controllers can program function blocks in C. The edited function block can be called at will in the program, which has good confidentiality and applicability, and reduces the workload of programming.

Power-on stop function:

In the XC series of programmable controllers, there is an important function, which is power failure. When there is a serious error in the operation of the programmable controller, which may lead to machine failure or damage, all outputs can be stopped immediately. In addition, the wrong setting of the communication parameters can also be connected to the programmable controller by this method, and then the communication parameters can be modified.

Communication Functions:

The XC series programmable controller can support a variety of communication modes such as basic Modbus communication, CANBUS communication, and free-form communication. In addition, it can access Ethernet and GPRS networks through specific network modules to accommodate a wider range of applications.
More on that
The difference between PLC, DCS and FCS - Xinjie The difference between PLC, DCS and FCS - Xinjie

The fundamental characteristics of the three major control systems of PLC, DCS and FCS At present, there are three major control systems in the operation of industrial processes in continuous process production, namely PLC, DCS and FCS. The fundamental characteristics of each of them are as follows: 1PLC (1) From the development of switching control to sequential operation...

Xinjie inverter maintenance method Xinjie inverter maintenance method

In the instruction manual of the inverter, there is a column that discusses in detail the fault code display of the inverter.   1. Short-circuit maintenanceIf there is short-circuit maintenance on the side of the inverter's operation, "0" means that the inverter has short-circuit elements inside or outside. There are several reasons for this ...

Application characteristics of PLC in the control of mixing plant Application characteristics of PLC in the control of mixing plant

1. High reliability The PLC adopts a series of anti-interference methods in hardware and software, so that it can be directly installed in the industrial site and operate safely and reliably, anti-magnetic, anti-seismic and dust-proof. 2. Programming is simple and easy to grasp ...

Small PLC manufacturers introduce the classification of PLC - Xinjie Small PLC manufacturers introduce the classification of PLC - Xinjie

Small PLC manufacturers introduce that PLC products have a wide variety of products, and the specifications and performance are also different. The classification of PLCs is usually based on their structure, function and number of I/O points. 1. Classified by input/output points (1) ...

Attention to the solution of heat dissipation in the application of inverter - Xinjie Attention to the solution of heat dissipation in the application of inverter - Xinjie

Assuming that the inverter has a long service life, heat dissipation must be carefully considered. Because the equipment failure rate of the inverter increases exponentially with the increase of temperature, the service life decreases. If the operating temperature rises by 10 degrees, the service life of the inverter will decrease. ...

The development status of human-computer interface shopping malls in China The development status of human-computer interface shopping malls in China

The development status of human-computer interface shopping malls in China China is the shopping mall with the largest demand for human-computer interface in the world, but it is not the shopping mall with the highest sales of human-computer interface products in the world.

How to choose an industrial display touch screen - Xinjie How to choose an industrial display touch screen - Xinjie

  1. Four-wire resistive touch screen: It is not afraid of dust, oil and photoelectric disturbance, and is afraid of scratches is its main defect. It is suitable for public places with fixed users, such as industrial control sites, offices, homes, etc.; 2. Five-wire resistor ...

Thermal Relay Current Tuning - Xinjie Thermal Relay Current Tuning - Xinjie

(1) What is the current setting value of the thermal relay? The setting current of the thermal relay refers to its action current, that is to say, it is adjusted between 0.95 - 1.05 times of the rated current of the motor being maintained.

PLC control system design steps and precautions - Xinjie PLC control system design steps and precautions - Xinjie

1. Hardware purchase At present, there are a large number of PLC products on the market, more and more cost-effective, and the optional fields are getting bigger and bigger. 1. At the beginning of the scale of the system, it should be determined that the system is a single PLC machine.

Quick steps to debug the inverter – Xinjie Quick steps to debug the inverter – Xinjie

1. Check the full-load power supply of the inverter (Variable-frequency Drive (VFD). 1. Ground the terminal strip of the VFD. 2. Type the switching power supply of VFD into the terminal and receive it from the switching power supply through the power switch of the leakage protector. 3. ...

Learn PLC programming skills - Xinjie PLC Learn PLC programming skills - Xinjie PLC

1. When the PLC and the host computer (or touch screen) form a monitoring system, there are many times on the screen that there are "manual", "active" and other control modes (generally more than one). In the program, you can use the "MOV" command. For example, when selecting "manual", the constant 1MOV will be ...

The inverter operates normally in a humid environment The inverter operates normally in a humid environment

1. Look inside the electrical cabinet, for example, to see if there are small animals and their droppings, and whether there are condensation or water marks. If the dust in the cabinet is large, please clear the external radiator of the inverter. 2. Assuming that the humidity is relatively large, there are condensation or water marks, please open the cabinet door first, ventilate and dehumidify, you can use electric fans, etc.

Superheat treatment method of Xinjie inverter drive motor Superheat treatment method of Xinjie inverter drive motor

Why does the motor driven by the inverter overheat? This is due to the fact that the voltage of the inverter drive motor contains a rich high-frequency component. The voltage waveform of the inverter-driven motor is not a sine wave voltage, but a pulse-width modulation (PWM) voltage. According to Fu Liye's analysis, this waveform ...

The solution to the overcurrent of the inverter - Xinjie The solution to the overcurrent of the inverter - Xinjie

1. On the premise of satisfying the production equipment and process requirements, the acceleration or deceleration time should be increased as much as possible, and then the overcurrent generation in the process of acceleration or deceleration can be avoided. 2. Check whether the inverter, motor, and production equipment are well matched, whether the transmission part is sensitive, and whether the material is ...

The main functions of the Xinjie touch screen and PLC control system The main functions of the Xinjie touch screen and PLC control system

(1) The entire control process works under the Chinese system, and the handling is completely Chinese (2) Realize the active control of batching, blanking, mixing and concrete displacement (3) The mixing time and blanking sequence can be adjusted immediately (4) Batching, blanking, mixing ...

Inverter technology strategy in electromechanical control Inverter technology strategy in electromechanical control

In the process of century industry, the more top-level software and hardware planning for the suspension of frequency conversion skills, first according to the characteristics of traditional air compressor motors, comprehensively analyze the causes of energy consumption and operation characteristics, so as to plan the control of frequency conversion skills speed regulation, air skill tightening, pressure sensing skills improvement, etc.

Common faults of wires and cables - Xinjie Common faults of wires and cables - Xinjie

The most direct cause of cable problems is the breakdown due to the loss of insulation. First of all, there are: a. Overload operation. Long-term overload operation will increase the temperature of the cable, aging the insulation, resulting in breakdown of insulation and degradation of construction quality. b. Electrical: the construction process of the cable head does not meet the requirements.

Advantages and opportunities of domestic PLC - Xinjie PLC Advantages and opportunities of domestic PLC - Xinjie PLC

At present, in the domestic PLC market, there are many kinds, but there are not many domestic PLC manufacturers with real strength, most of the domestic PLC is not an individual without legal person qualifications, or a single-chip microcomputer enthusiast, from the domestic PLC factory to buy the underlying programming code or buy a domestic PLC chip (the domestic P ...

Differential amplifier overhaul method of Xinjie inverter Differential amplifier overhaul method of Xinjie inverter

Problem example 1 On the telegram OC problem, measure the 5, 6, and 7 pins of N1 to be 2V. Pin 7 is not 0V for the alarm reason. 1. The "imaginary short" rule of the amplifier is still established, and the N1 chip is good to judge, but the fault is in the bias circuit. 2. Further analysis, at this moment the differential amplifier has ...

Xinjie PLC failure and solution Xinjie PLC failure and solution

Xinjie PLC conditions are established, why is the corresponding coil not in place? There are two possible reasons for this: (1) The same coil may be used in multiple places to perform the double coil output, and when the double coil is output, the coil on the rear side will operate first. (2) ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top