Analysis of problems encountered by Xinjie PLC

Create Date: 2024-8-30 12:03:23|Source: XINJE

Xinjie PLC丨The condition is established, why is the corresponding coil not in place? There are two possible reasons for this:

(1) The same coil may be used in multiple places to perform the double coil output, and the coil on the rear side will operate first when the double coil is output.

(2) At this moment, the reset condition of the coil is also established. The user can find the reset point and modify the program through the monitoring function.

                              Analysis of problems encountered by Xinjie PLC

Xinjie PLC 丨Communication failure is generally summarized as the following problems:

(1) Communication parameters: The communication parameters of Xinjie PLC communication port and peripheral equipment may be inconsistent.

(2) Communication line: If the connection may be incorrect, or the contact is poor, the user can replace the communication line and try again.

(3) Communication serial port: to view the communication serial port, you can view it by downloading the Xinjie PLC program, and the serial port problem will be eliminated if the download is successful.

More on that
Interference within the PLC remote module system - Xinjie PLC Interference within the PLC remote module system - Xinjie PLC

The internal disturbance of the PLC system is mainly caused by the mutual electromagnetic radiation between the components and circuits inside the system, such as the mutual radiation of logic circuits and their influence on the imitation circuit, the interaction between the imitation ground and the logical ground and the mutual mismatch between components. How to deal with PLC long distances effectively ...

The reason for the abnormal alarm in PLC - Xinjie The reason for the abnormal alarm in PLC - Xinjie

With the continuous development of industrial automation, PLC is widely used in industrial control professions. No matter how strong the PLC product is, it often fails to work normally. All kinds of brands of PLC have the function of self-diagnosis, but the skill of PLC repair is that when the PLC is abnormal, the function should be fully used.

The cause of abnormal noise of PLC input and output module - Xinjie The cause of abnormal noise of PLC input and output module - Xinjie

Input and output module, if it is the kind of relay output, it is normal to have a little movement, because the relay is a mechanical equipment, there will be a little noise during the action, but the average person can not hear it, if it is obvious, it is estimated that the relay is broken, such as a short circuit between the turns of the coil, please pay attention to: Rongji point ...

PLC control back troubleshooting method - Xinjie PLC control back troubleshooting method - Xinjie

1. PLC input and output A small PLC controls a complex system with agility, and what can be seen is the upper and lower rows of staggered input and output relay terminals, corresponding lamps and PLC numbers, just like a piece of integrated electricity without dozens of feet. If any ego doesn't look at reason...

Xinjie plc programming software XCPPro Xinjie plc programming software XCPPro

XCPPro is a professional XCPPl programming software, which is a new XC series PLC programming software, which can be used normally by making corresponding configurations in XCPPro. The software supports WindowsXP32-bit Win764-bit system. ...

XDH | XLH series of 16-axis high-performance EtherCAT controllers XDH | XLH series of 16-axis high-performance EtherCAT controllers

The XDHI XLH series of 16-axis high-performance EtherCAT controllers is the perfect choice for small motion control. Product model XDH-30A16-E/XDH-30A16L-E Small/16-axis type Frequency: 600MHz Program Capacity: ...

Application of PLC programming in CNC maintenance - Xinjie Application of PLC programming in CNC maintenance - Xinjie

CNC machine tool is the abbreviation of digital control machine tool, which is an automatic machine tool equipped with a program control system. The control system is the numerical control system, the numerical control system can logically process the program with the control code or other symbolic instruction rules, and decode it, so that the machine tool action and add ...

Explanation of some common fields of inverter - Xinjie inverter Explanation of some common fields of inverter - Xinjie inverter

1. The inverter is used in the air conditioning load class Office buildings, shopping malls and some supermarkets and factories have central air conditioning, and the electricity consumption of air conditioning is very large at the peak of electricity consumption in summer. In the hot climate, Beijing, Shanghai, Shenzhen air conditioning ...

Common problems and solutions of Xinjie PLC Common problems and solutions of Xinjie PLC

1. Why can't the PLC communicate with the peripherals? Communication failures are generally summarized as the following problems: 1. Communication cable: The connection may be incorrect, or the contact is poor, the user can change the communication cable and try again. 2. Communication parameters: PLC communication port and peripheral equipment ...

The characteristics of the inverter in the process of development - Xinjie The characteristics of the inverter in the process of development - Xinjie

The frequency converter is a power converter in the motion control system. Today's motion control system includes many technical fields, and the general development trend is: communication drive, high-frequency power changer, digital, intelligent, and networked control. VFDs are power converters in motion control systems. ...

Xinjie Electric joins hands with Zhongchi Fulian to create a new future of smart industry Xinjie Electric joins hands with Zhongchi Fulian to create a new future of smart industry

On the afternoon of March 20, Wuxi Xinjie Electric Co., Ltd. signed a strategic cooperation agreement with Henan Zhongchi Fulian Seiko Technology Co., Ltd. Li Xin, Chairman of Xinjie Electric, Feng Guangwei, Deputy Director of the Electronic Information Department of the Investment Promotion Bureau of the Airport Pilot Zone, and Liu Guangwei, Executive President of Foxconn Technology Group.

Xinjie PLC problems and solutions Xinjie PLC problems and solutions

Xinjie PLC 丨Communication failure is generally summarized as the following problems: (1) Communication parameters: The communication parameters of Xinjie PLC communication port and peripheral equipment may be inconsistent. (2) Communication line: The connection may be incorrect, or the contact is poor, the user can replace the communication line and try again.

Xinjie inverter control mode Xinjie inverter control mode

The output voltage of low-voltage general frequency conversion is 380-650V, the output power is 0.75-400kW, and the working frequency is 0-400Hz. Its control methods have gone through the following four generations. 1U/f=C Sine Pulse Width Modulation (SPWM) Control Method ...

Common faults of wires and cables - Xinjie Common faults of wires and cables - Xinjie

The most direct cause of cable problems is the breakdown due to the loss of insulation. First of all, there are: a. Overload operation. Long-term overload operation will increase the temperature of the cable, aging the insulation, resulting in breakdown of insulation and degradation of construction quality. b. Electrical: the construction process of the cable head does not meet the requirements.

An overview of the precise timing instructions of the Seejet PLC An overview of the precise timing instructions of the Seejet PLC

Make accurate punctuality, read accurate punctuality, and stop accurate punctuality. Watchman number. Range: T600 - T618 (T600, T602, T604...) T618, numbered even) Punctuality. Accurate punctuality ...

The cause of the overcurrent of the Xinjie inverter The cause of the overcurrent of the Xinjie inverter

1. Non-short-circuit overcurrent, which is mainly due to: (1) The motor is severely overloaded. (2) The motor accelerates too fast. (3) Due to the U/f ratio (torque compensation) setting is too high, the motor is in a light load condition. 2. Short circuit ...

Advantages of Xinjie XDM series motion control PLC Advantages of Xinjie XDM series motion control PLC

Xinjie XDM series PLC, XDM is the sports control PLC in the XD series, now has the following types: XDM-24T4-E/C, XDM-32T4-E/C, XDM-60T4-E/C, XDM-60T10-E/C. The XDM series has the following ...

Xinjie PLC inverter visual system Xinjie PLC inverter visual system

XC can be divided into multiple sub-series according to the incompatibility of functions, including XC1 (economy), XC2 (foundation), XC3 (standard), XC5 (enhanced) and their corresponding expansion modules, as well as special imitation ontology, activity control models, etc. Powerful function, complete variety, can be full ...

Anti-interference countermeasures for PLC and touch screen - Xinjie Anti-interference countermeasures for PLC and touch screen - Xinjie

1. Select the power supply with excellent performance and press the disturbance introduced by the power grid The power supply of the PLC controller is powered by a non-power line, and is powered by a special line directly led by the main bus of the low-voltage distribution room. Barrier transformer should be selected, the transformer capacity should be 1.2-1.5 times larger than the actual need, and can be used in the barrier...

The difference between Xinjie inverter and inverter power supply The difference between Xinjie inverter and inverter power supply

What is a frequency converter? Variable frequency drive (VFD) uses inverter technology and microelectronics to change the operating power frequency of the motor to control the power control unit of the communication motor. The inverter is mainly composed of rectifier (from communication to DC), inverter, inverter (from DC ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top