Failure analysis of Delta inverter VFD-VL series

Create Date: 2024-8-30 12:03:23|Source: Delta/Delta

Fault 1: Overcurrent in acceleration

Clarification: Overcurrent in acceleration

Solution 1: Check whether the wiring from U-V-W to the motor is poorly insulated;

2: Increase acceleration and deceleration time;

3: Replace the inverter with a larger output capacity;

4: Reduce (P54) torque and increase the set value;

5: If the above methods are invalid, send them to the original factory for repair.

                               Failure analysis of Delta inverter VFD-VL series

Fault 2: Overcurrent is generated during deceleration

Clarification: Overcurrent generation during deceleration

Solution 1: Check whether the wiring from U-V-W to the motor is poorly insulated;

2: Increase acceleration and deceleration time;

3: Replace the inverter with a larger output capacity;

4: If the above methods are invalid, send them to the original factory for repair.

More on that
The specific operation method of Delta inverter The specific operation method of Delta inverter

(1) When the speed of the motor is controlled by the Delta inverter, the noise and temperature rise of the motor are higher than that of the frequency of the motor. When the motor is working at low speed, due to the low speed of the motor blades, the temperature rise of the motor becomes high.

Delta's inverter power-on debugging method Delta's inverter power-on debugging method

After the inverter is installed, disconnect the output of the inverter, use the diode file of the digital meter to measure the input and output of the inverter before the power is not turned on, ensure that there is no short circuit, and then turn on the working power supply of the inverter.

Delta's PLC programmable controller product list Delta's PLC programmable controller product list

1. Programmable manipulator AH series Delta's AH series modular controllers provide automation system solutions for high-end applications. The AH series adopts a comprehensive modular design, and on the basis of Delta's research and development skills, it has developed ...

Delta has always been the shipment champion in Taiwan's inverter market Delta has always been the shipment champion in Taiwan's inverter market

Based on trend forces, the sales market of solar power generation in Taiwan was analyzed. In the first half of 2019, AUO ranked second, while third-ranked Canada Solar entered the top three for the first time. Compared with the previous year, the sales market in Taiwan, China in the first half of 2019 was in the total delivery of common decoration ...

Inverter encoder role - Delta Inverter encoder role - Delta

In the case of low speed accuracy requirements or small load changes, the inverter can be selected. The U/f control method refers to the method of controlling the frequency and voltage of the inverter. The rotational speed change in this control method is done by changing the set value of the frequency. ...

Precautions for Delta's DPA pressure sensor Precautions for Delta's DPA pressure sensor

1. When the device is installed, leave the place with high voltage and strong high-frequency noise to prevent disturbance. Prevent use in places where the following conditions occur: (a) Excessive dust and corrosive gases; (b) high humidity and very high radiation; (c) ...

Advantages and disadvantages of Delta's open-loop and closed-loop control Advantages and disadvantages of Delta's open-loop and closed-loop control

1. Open-loop control There is no reverse connection between the controller and the controlled target, and the control is carried out in one direction. Strengths: Simple, stable and reliable. If the characteristics and parameter values of the components that make up the system are relatively stable, and the external disturbance is small, the open-loop control energy Enough...

Delta inverter repair steps Delta inverter repair steps

Delta inverters still have a certain influence in the industry, but even if the reputation is good, it will inevitably show some failures. Let's take a look. ...

Introduction to Constant Power and Constant Torque in Frequency Conversion Speed Regulation - Delta Introduction to Constant Power and Constant Torque in Frequency Conversion Speed Regulation - Delta

In general, factory motors are based on the additional speed values obtained at a given power frequency voltage (380 V, 50 Hz). If 380V is not reached under actual operating conditions, e.g. as long as 300V, 50 Hz, the voltage is significantly undervoltaged. Fundamentally, it cannot reach the extra rev value, due to the ...

The principle, composition and function of Delta's inverter The principle, composition and function of Delta's inverter

1. What is a Delta inverter? Delta inverter is a device that converts the power supply (50Hz or 60Hz) into a communication power supply of various frequencies to realize the variable speed operation of the motor.

Routine maintenance of Delta UPS power supply equipment Routine maintenance of Delta UPS power supply equipment

The inspection personnel should record the operation status, voltage and current values of the UPS every day, and deal with the problems in a timely manner. Check whether the traffic lights are working properly; Keep the outside of the battery clean; Check the operating status of the battery pack ...

Selection of Delta power supply Selection of Delta power supply

There are many models of Delta's power supplies, and the currents and functions supported are also different, so how to choose?   VX Series Power Supplies. VX270: Active PFC270w, but 12v is still small and can only be used at low power. Active PFC and 12v output up to 276w at 300...

Precautions for initial installation of Delta inverters Precautions for initial installation of Delta inverters

Delta's inverters should be thoroughly inspected for the first time or after long-term installation. The items and methods of inspection are as follows: 1) Check whether the Delta inverter is damaged, whether the metal parts are rusty, and whether there is frost. If there is frost and condensation, it should be dried for 4 hours (60°C) or ...

Delta's PLC-Based motion controller AX3 series Delta's PLC-Based motion controller AX3 series

With the development of electronic semiconductor information technology, technologies such as the Internet of Things, big data, and cloud channels are showing a trend of a hundred flowers blooming, which also drives the rapid development of intelligent production. Intelligent production also puts forward new requirements for controllers: high speed, large capacity, miniaturization, networking...... In order to ...

Brand inverter modifies the power method - Delta Brand inverter modifies the power method - Delta

What are the benefits of inverter power correction? Many brands of inverter power boards, driver boards, and motherboards can be universal, as long as the type, volume, and hardware are the same, and the desired power and voltage value can be obtained by correcting the manufacturer's parameters.

Delta inverter password Delta inverter password

The inverter of Delta's brand A series locks the keypad to correct the parameters, forming that most of the parameters cannot be corrected, and the manual does not clearly explain how to unlock the keypad lock, press MODE and RESET together to display P256 (P256 does not explain what it means in the manual), press ENTER...

Delta was awarded an "A" rating as a "Supply Chain Engagement Leader." Delta was awarded an "A" rating as a "Supply Chain Engagement Leader."

On February 10, CDP released its 2021 Supplier Engagement Rating; SER) As a result, Delta received the highest scores in key scoring items such as "Supply Chain Participation" (Note 1) and "Three Emissions in the Greenhouse Gas Field" (Note 2).

The impact of Delta's inrush current on the inverter The impact of Delta's inrush current on the inverter

In the process of repairing the inverter, it is found that because of the back electromotive force in the stator winding, the electromotive force in the synchronous generator state and the self-induced electromotive force in the self-induced rotor, the current impact must have a negative impact on the motor, the inverter (Variable-frequency Drive, ...

The basic control loop of Delta's inverter The basic control loop of Delta's inverter

There are two fundamental circuits for communicating with external signals: analog and digital: 1. 4-20mA current signal loop (imitation); 1 - 5V/0 - 5V voltage signal loop (imitation). 2. Switch signal circuit, inverter start and stop command, forward rotation command, etc.

How the components of the inverter work – Delta How the components of the inverter work – Delta

1. Inverter element - rectifier Since it is difficult to change the frequency of the communication sine wave in the form of communication, the first operation of the inverter is to convert the waveform into direct current. To make it look like an AC, it is relatively easy to operate the DC. The most important component of all inverters is a ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top