1. Precautions for choosing a communication motor driver
When using a high-capacity current transformer (600kVA or more) and a phase capacitor, the surge current on the input side of the power supply is too large, which may destroy the input side of the AC motor driver, so it is necessary to install a communication reactor on the input side to reduce the current and improve the input power.
When driving a special motor or a communication motor driver to drive multiple motors, the total additional current of the motor should not exceed the additional current of the communication motor driver, and the choice of communication motor driver should be very careful.
When the AC motor driver drives the motor, the starting, acceleration and deceleration characteristics of the Delta inverter are constrained by the additional current of the AC motor drive, and the starting torque is small (6 times the starting current when the commercial power supply is started directly, and the starting current cannot exceed 2 times when the AC motor driver is started), so in places that require high starting torque (such as elevators, mixers, east-west machines, etc.), it is necessary to increase the application of the communication motor driver by 1 or 2 levels, (*** The ideal way is to increase the motor and the communication motor driver by one level together).
It is necessary to consider the stopping method of the motor and mechanical equipment in the event of an abnormal fault stop output of the communication motor driver, and if it is necessary to stop suddenly, it is necessary to add mechanical brakes or mechanical brake equipment.
2. Precautions for parameter setting
Since the speed of the digital operator can be set up to 400Hz, the output frequency can be constrained by using the speed cap function when there is a high-speed constraint place. If the DC braking voltage and braking time value are set too high, the motor may overheat.
The acceleration and deceleration time of the motor is determined by the additional torque of the motor, the torque required by the load, the inertia of the load, etc.
If the acceleration and deceleration is necessary to be very fast, and the load inertia is large, and the communication motor driver cannot accelerate or stop the motor at the required moment, it is necessary to apply an additional braking resistor (which can only shorten the deceleration time) or increase the motor and communication motor driver by one level.
|
More on that
|
Precautions for the operation of Delta servo motors
1) The AC servo motor works by means of a dedicated drive. Do not connect the commercial power supply (100/200V, 50/60Hz) directly to the line of the servo motor, otherwise the servo motor will not work properly and the servo motor will be permanently damaged.
...
|
|
Common problems of VFD control motors - Delta
Question 1. Why use a VFD to control the motor?
Speaking of this question, let's first take a brief look at these two devices. The motor is a rational load, which hinders the change of current, and a large change in current will occur when it is started. VFD, which is actually made up of a rectifier inverter circuit, ...
|
|
Servo motor speed improvement method - Delta
When many engineers debug servo motors, they often have such a problem: why is my servo motor so slow, how can I improve the speed, and how much can the maximum speed reach? The basis for the confirmation of the speed method of the servo motor: the speed of the servo motor.
...
|
|
Analysis of misunderstandings in the application of Delta inverters
The capacity selection of the inverter is based on the rated power of the motor
Myth: The capacity selection of the inverter is based on the rated power of the motor
Compared with the motor, the price of the frequency converter is the most expensive, so under the premise of ensuring safe and reliable operation, the frequency conversion can be reasonably reduced.
|
|
Troubleshooting of small electromagnetic relay cores - Delta
The main problems of the iron core of the small electromagnetic relay are that the armature cannot be sucked after being electrified:
This may be due to broken coils, foreign matter between the moving and static cores, and low power supply voltage. It should be patched on a case-by-case basis.
When energized, the armature is noisy:
This may be because of the ...
|
|
Delta launched the MZM, a high-power positional drive system
Driven by consumption promotion and product diversification, the manufacturing industry's demand for automation and intelligent promotion in production and processing is also increasing. In the production process, the processing of "large and heavy" items is often difficult to control accurately, and the deviation of orientation is not as easy as that of "small" items. To this end ...
|
|
Factors affecting Delta's inverter motors and countermeasures
1. The influence of leakage current on the motor and countermeasures
If the wiring length is very long, the stray capacitance between the wires will increase, resulting in leakage current. It will initiate overcurrent maintenance, increase leakage current or not ensure the correctness of the current display. The bad situation is that the inverter will ...
|
|
How to use a PC to control Delta's inverter
Problem Description:
How does Delta inverter use a PC to control it?
Solution(s):
The communication interface of Delta's inverter is based on RS485 and the ModBus communication pattern commonly used in the general industry for material handing.
|
|
Precautions for the use of Delta inverter MS300 series
Before operating the MS300 series products, please read and pay attention to the relevant safety information to ensure your own safety and product safety.
When operating the wiring and installing the inverter, it is necessary to confirm that the power supply is closed.
After blocking the communication power supply, the inverter POWER indicator (located in ...
|
|
Pulse control wiring method for Delta servo drives
Parameter settings
P1-XX are the basic parameters
P1-00 pulse method selection, *** bit selection is 2, that is, pulse train + direction
P1-00 signal logic picking, the third digit is selected as 0 or 1, which is the positive logic or anti-logic, X0XX or X1XX
P1-01 Control form selection, pick ...
|
|
The reason why the circuit breakers of multiple stages trip together is Delta
Short-circuit maintenance (overload maintenance) is an important function of circuit breakers, and the reason why this function is achieved is that the circuit breaker senses the temperature in the circuit through a thermal iron plate. Once the temperature in the circuit is too high, it is transmitted to the mechanical mechanism in the circuit breaker for trip maintenance.
...
|
|
Inverter performance test method - Delta
As we all know, the inverter has many maintenance functions, such as overcurrent, overvoltage, overload maintenance and so on. With the continuous improvement of industrial automation, frequency converters have also been widely used. This article will explain to you how to use a multimeter to measure the quality of the inverter.
Need...
|
|
Delta's Ultron NT series UPS escorts flight safety at international airports
The rapid development of the national economy has opened up a broad shopping mall space for the growth of the civil aviation industry. In order to meet the surge in the number of flights, an international airport in Northwest China has invested in the third phase of the expansion project, and has been listed as the "number one project" for civil aviation development and the "benchmark demonstration project" for national civil aviation.
|
|
A number of Delta's new high-end power supply products were unveiled at CMEF
Delixi Electric's newly launched CDQ1F series PC-level excitation active transfer switch, with more complete specifications and stronger functions, the power-off time can be shortened to less than 0.1s, escorting the continuous use of electricity in important places!
CDQ1F Active ...
|
|
Touch screen controls the inverter step – Delta
1. The touch screen is controlled by PLC inverter
1. At present, the general control of the inverter needs to choose PLC to communicate with the inverter, read the information of the inverter, and then the touch screen communicates with the PLC to complete the control of the inverter to start, stop, and monitor the operation of the inverter.
|
|
Solution: Delta's inverter operation error
There are many setting parameters of the inverter, each parameter has a certain selection scale, and the inverter can not work normally due to the improper setting of a single parameter is often encountered in the application, therefore, the relevant parameters must be set correctly.
...
|
|
Precautions for long-term idle use of Delta inverter
If the inverter is to run the equipment again after being shelved for more than half a year, the probability of damage may be greatly increased due to many factors such as the placement environment, the service life of the inverter, and the load rate, and the failure usually presents the following problems:
1. After the equipment is powered on, it becomes ...
|
|
Introduction to the common sense of Delta inverter
The low-voltage fuse cannot be used as an overload maintenance for the motor.
It is necessary that the additional voltage of the fuse is greater than or equal to the operating voltage of the distribution line.
The additional current of the fuse must be greater than or equal to the additional current of the melt.
...
|
|
Delta servo problem analysis
1: What is the difference between servo motor and general motor?
The biggest difference between servo motors and general motors is the motor rotor and reaction equipment. The surface of the servo motor rotor is pasted with a strong magnetic plate, so that the magnetic field generated by the stator coil can control the orientation of the rotor, and the acceleration and deceleration characteristics are ...
|
|
Selection of Delta power supply
There are many models of Delta's power supplies, and the currents and functions supported are also different, so how to choose?
VX Series Power Supplies.
VX270: Active PFC270w, but 12v is still small and can only be used at low power.
Active PFC and 12v output up to 276w at 300...
|
|