The inverter is the pioneering work of Delta Automation, and it is also the largest selling product of Delta Automation. In the highly competitive market, Delta inverters have always maintained a strong growth momentum and made great achievements in the high-end product market and the economic product market. Delta continues to launch high-end products, expand applications in high-end fields, and win the increasingly competitive inverter market with strength.
There are many setting parameters of the inverter, and each parameter has a certain range of choices. In the process of use, due to improper setting of individual parameters, the inverter often fails to work normally.
Control mode: speed control, rotation control, PID control or other modes. After adopting the control mode, it is generally necessary to carry out static or dynamic identification according to the control accuracy.
Minimum operating frequency: i.e. the minimum speed at which the motor can run. When the motor is running at low speeds, its heat dissipation performance is very poor. When the motor is running at a low speed for a long time, it will cause the motor to burn out. In addition, at low speeds, the current in the cable also increases, and the cable heats up.
Maximum frequency: the maximum operating frequency of the general inverter is 60Hz, some even 400Hz, high frequency will make the motor run at high speed, which is for ordinary motors, its bearings can not run beyond the rated speed for a long time, whether the motor rotor can withstand this centrifugal force.
Carrier frequency: The higher the carrier frequency is set, the larger the higher harmonic component, which is closely related to factors such as cable length, motor heating, cable heating and inverter heating.
Motor parameters: The inverter sets the power, current, voltage, speed, and maximum frequency of the motor in the parameters, and these parameters can be obtained directly from the motor nameplate.
At a certain point in the jump frequency, resonance may occur, especially when the overall device is relatively high; When controlling the compressor, avoid the surge point of the compressor.
|
More on that
|
Misunderstandings of power-saving and energy-saving use of inverters
Industrial control automation products inverters are depicted as power-saving, energy-saving control automation products, therefore, many people will think that as long as the equipment is installed with inverters, it will be able to save energy, but this is not the case.
The inverter of industrial automation products itself produces energy-saving ...
|
|
Introduction to the basic application of Delta inverter
Generally, household appliances use a single-phase asynchronous motor, which relies on capacitance or resistance to split the phase. Motors are often in a short-term repetitive state (on/off) during operation, such as air conditioners, refrigerators, etc. This will inevitably lead to frequent starting, high noise, short motor life, poor temperature stability and energy consumption.
|
|
Composition and function of Delta inverter
Delta inverter is a device that converts the power supply (50Hz or 60Hz) into AC power supply of various frequencies to realize the variable speed operation of the motor.
|
|
Introduction to Delta's PLC maintenance knowledge
1. Delta's PLC power on running light does not light up, and the ERROR flashes, the reason may be: no program
2. Delta's PLC cannot communicate with the computer, which may be: RS23 port is broken
3. Delta's PLC power light does not light up: The power supply is bad
...
|
|
The basic methods and steps of inverter debugging - Delta inverter
1. No-load energizing test of inverter
1. Ground the grounding terminal of the inverter.
2. Connect the power input terminal of the inverter to the power supply through the leakage maintenance switch.
3. Check whether the factory display window of the inverter is normal, if it is incorrect, it should be reset, no ...
|
|
Pulse control wiring method for Delta servo drives
Parameter settings
P1-XX are the basic parameters
P1-00 pulse method selection, *** bit selection is 2, that is, pulse train + direction
P1-00 signal logic picking, the third digit is selected as 0 or 1, which is the positive logic or anti-logic, X0XX or X1XX
P1-01 Control form selection, pick ...
|
|
Delta's PLC programmable controller product list
1. Programmable manipulator AH series
Delta's AH series modular controllers provide automation system solutions for high-end applications. The AH series adopts a comprehensive modular design, and on the basis of Delta's research and development skills, it has developed ...
|
|
Precautions for long-term idle use of Delta inverter
If the inverter is to run the equipment again after being shelved for more than half a year, the probability of damage may be greatly increased due to many factors such as the placement environment, the service life of the inverter, and the load rate, and the failure usually presents the following problems:
1. After the equipment is powered on, it becomes ...
|
|
Delta's inverter process setting
1. Restore the inverter to factory settings, press the "ENTER" button to enter the parameter setting interface, and press it continuously until it is 00-00 and then stop. Press the number up button to change to 00-02. Press the "ENTER" key again, the panel value will show 0, press the number up key to change it to 9. Press the "ENTER" key, break ...
|
|
Delta's Ultron NT series UPS escorts flight safety at international airports
The rapid development of the national economy has opened up a broad shopping mall space for the growth of the civil aviation industry. In order to meet the surge in the number of flights, an international airport in Northwest China has invested in the third phase of the expansion project, and has been listed as the "number one project" for civil aviation development and the "benchmark demonstration project" for national civil aviation.
|
|
Do Delta thermostats have a "slope control" function?
Delta's thermostats are only available in the DTE series (variety 1.5 and above) with the "slope control" function.
Illustrate the following examples:
For example: PV=20°C, SV=100°C, slope 10.0°C/min
Then (100 – 20)/10.0 ...
|
|
Delta's soft starter component role
The soft starter is a device used to control the start and stop of the motor, which is composed of a number of components, including the soft starter controller, the soft starter conditioner, the soft starter power supply, the soft starter input and output module, the soft starter interface module, etc.
...
|
|
The benefits of using an inverter – Delta inverter
1. Speed regulation of general motor: By changing the input voltage and frequency of the three-phase asynchronous motor, its speed can be controlled. Generally, when the motor is at low speed, the temperature rise becomes larger due to the decrease in the power of the cooling fan, and the motor load should be reduced according to the frequency.
2 ...
|
|
Delta's Ultron HPH provides power protection that meets the needs of green data centers
Delta's Ultron HPH series UPS has an AC-AC efficiency of up to 96%, and can reach 99% in ECO mode, with significant energy savings. The flexible airframe provides a compact footprint (40kW / 0.15 m2) and reduces space waste. With an interface-friendly 5-inch colorful touch screen, ...
|
|
Introduction to common models and parameters of Delta touch screens
There are many types of Delta contact screens, of course, the parameters of different types are different, and the most important product is DOP-B03S201. This product is a 4.3-inch screen, its aspect ratio is 16:9, the screen is made of TFT raw materials, and its resolution can reach 480X ...
|
|
Inverter performance test method - Delta
As we all know, the inverter has many maintenance functions, such as overcurrent, overvoltage, overload maintenance and so on. With the continuous improvement of industrial automation, frequency converters have also been widely used. This article will explain to you how to use a multimeter to measure the quality of the inverter.
Need...
|
|
The inverter has a built-in PLC function - Delta
PLC progressive scanning standard work preparation.
Abundant programming language: instruction statements; ladder diagram; SFC。
Abundant instruction statements: 45 instruction varieties, including 28 root instructions and 17 usage instructions.
350 step law capacity.
uS-level root directives ...
|
|
Inverter maintenance is easy to ignore the problem - Delta
1. After the inverter is repaired, the power number needs to be corrected, don't forget it
Generally, an inverter corresponds to a power number (also known as the number of horsepower), for example, a 75 kilowatt inverter is set under heavy load, and 100 kilowatts is set under light load. In this way, the customer will not use it to present ...
|
|
Requires an inverter speed control application – Delta
Inverter is a kind of speed regulation equipment, where is there a place to use motor speed regulation, especially asynchronous motor speed regulation, will use inverter, now it is mainly used in industrial equipment on a large scale, because the motor is the heart of industry, and three-phase asynchronous motor occupies the vast majority of the share, ...
|
|
Delta's inverter external positive and reverse operation mode
1. The external control panel is rotated and operated
After selecting the upper or lower button on the panel, the Frd inverter will rotate forward if you select the inverter, and the rEu inverter will rotate
2. The external control terminal is rotated
Access via external terminals ...
|
|