In recent years, in response to the development trend of automation, informatization and intelligence, pharmaceutical companies have continuously innovated, transformed and upgraded, selected fully automated intelligent production lines, accelerated the upgrading of equipment in the pharmaceutical industry, completed the use of smart pharmaceutical technology for green, safe, high-quality and low-consumption development of the pharmaceutical industry, and accelerated the development of the pharmaceutical industry to become a world pharmaceutical power. In order to ensure the reliable operation of key equipment in the fully automated intelligent production line of pharmaceuticals and ensure the quality of drugs, especially biopharmaceuticals, the production line is usually equipped with an uninterruptible power supply (UPS) system to ensure safe production.
The original UPS system of a large pharmaceutical group in East China is supporting the control of the production line, and the single-chip microcomputer-like method is used to complete the control, and the software is used to complete the control by itself. The maintenance of the electrical part of the whole equipment is very difficult, and it also brings problems to the customer's self-modification. Therefore, customers urgently need to upgrade the UPS system.
After thorough research, Delta has provided customers with about 1,000 Amplon N series 3kVA UPS solutions, which provide power to the temperature control meters, controllers, and upper monitoring systems at the production line, bringing convenience to operation and maintenance.
Amplon N series is a low-power single-phase uninterruptible power supply system, which adopts a double-conversion online topology to provide stable and reliable sine wave power supply. Its industry-leading product advantages can create more benefits for users:
1. The output power factor is up to 0.9, and the high power of the whole machine is deployed, which can not only provide a safe power supply for the manufacturing production line, but also reduce the cost of energy consumption;
2. Its wide input voltage range allows the device to operate in a network with unstable parameters, and reduces the necessity of transferring to the battery power supply, thereby extending the service life of the battery;
3. The enhanced digital signal processor (DSP) has fast computing power, which can reduce the number of electronic parts required for control stability, and the LCD display with user-friendly interface can make it easier to monitor and handle the local end.
Currently, Amplon N-Series UPS is already in outstanding use by the pharmaceutical group. On the premise of ensuring the control function of the original equipment, the whole system saves the transformation space and facilitates further transformation of the equipment; Together, we have changed the disadvantages of difficult maintenance in the past, and truly completed easy maintenance, simple operation and stable operation, which has been highly recognized by customers.
|
More on that
|
Inverter performance test method - Delta
As we all know, the inverter has many maintenance functions, such as overcurrent, overvoltage, overload maintenance and so on. With the continuous improvement of industrial automation, frequency converters have also been widely used. This article will explain to you how to use a multimeter to measure the quality of the inverter.
Need...
|
|
A brief introduction to Delta's inverters and their models
Delta's VFD drives have now established a wide range of brand awareness in the industrial automation market. Each series of products is designed for different operation needs such as torque, loss, overload, overspeed work, etc., and is adjusted according to different industrial machinery attributes; It can provide customers with a variety of choices, and a wide range of ...
|
|
The inverter reported the cause of the grounding fault - Delta
Regarding the grounding problem, it can generally be swept away after the following steps (because most of the inverters are not easy to detect the current measurement of Hall components, it is very important to sweep the grounding caused by external conditions, and alternative methods can be selected if there are conditions, and it is still an external problem to change a normal load to see whether it is a problem of frequency conversion or an external problem ...
|
|
Delta servo system composition
The servo system is mainly composed of a servo controller, a drive circuit, a servo motor and the corresponding reaction testing equipment.
(1) Servo motor
Servo motor refers to the motor that controls the mechanical components in the servo system, and the servo motor has an encoder inside, which can respond to the movement in real time.
|
|
Problems in the use of Delta inverters and Delta motors
Delta's motors are the most frequently used rotating things so far, and with the development and spread of Delta inverters, they need to be used in conjunction with inverters.
However, in the process of combining inverters and motors, it is inevitable to encounter a lot of ...
|
|
The energy-saving principle of inverter - Delta
In order to ensure the reliability of production, all kinds of production machinery are designed with power drive, and there is a certain surplus when designing and matching power drive. When the motor cannot operate at full load, in addition to reaching the power drive requirements, the residual torque increases ...
|
|
Delta UPS uninterruptible power supply R-2K series
With the increasing demand for system switching power supply by computer technology, Delta UPS uninterruptible power supply R-2K series products have been paid more and more attention, and gradually developed into a kind of electrical engineering with the effects of voltage stabilizer tube, frequency stabilization, filtration, anti-electromagnetic and frequency emission influence, anti-operation voltage swimming, etc.
|
|
Solution to Delta's overload trip fault
1. The main reason for VFD overload
(1) Mechanical overload. The main characteristic of overload is the heating of the motor, which can be detected by reading the operating current on the display.
(2) The three-phase voltage imbalance leads to excessive running current in a certain phase, resulting in overload tripping. It is characterized by uneven heating of the motor ...
|
|
Delta's powerful NT series industrial-grade UPS
Delta's NT series industrial-grade UPS has always been an ideal choice for applications that require high power safety due to their high reliability and high-density planning. IGBT high-frequency switching sinusoidal pulse width modulation technology planning, which makes UPS have good power supply quality, high efficiency, low heat loss, noise ...
|
|
The difference between a general-purpose inverter and a vector inverter - Delta
There are two main differences between vector inverter and general inverter, the first is high control accuracy, and the other is high output torque at low speed. It can output 150%-200% of the rated torque. It should be vector frequency conversion is to decompose the motor current into D-axis current and Q-axis current, where D-axis current is excitation current ...
|
|
Inverter encoder role - Delta
In the case of low speed accuracy requirements or small load changes, the inverter can be selected. The U/f control method refers to the method of controlling the frequency and voltage of the inverter. The rotational speed change in this control method is done by changing the set value of the frequency.
...
|
|
Introduction and features of Delta PLC
Delta's programmable controllers, also known as Delta programmables, delta programmable controllers, delta programmable controllers, etc., are electronic devices specially designed by Delta for the industrial automation category to complete digital operations. Delta's PLC uses programmable memory to store execution logic inside it.
|
|
Delta's inverter method to reduce the failure rate
Daily inspection item 1 of Delta's inverter problem repair:
Check whether there are any abnormal changes in the sound of the motor during operation, including whether there is vibration during the operation of the motor.
Routine inspection item 2 of Delta inverter problem repair:
Check out the inverter installation environment is ...
|
|
Introduction to Delta's PLC maintenance knowledge
1. Delta's PLC power on running light does not light up, and the ERROR flashes, the reason may be: no program
2. Delta's PLC cannot communicate with the computer, which may be: RS23 port is broken
3. Delta's PLC power light does not light up: The power supply is bad
...
|
|
The power frequency motor is not normally installed with the inverter hazard
Installing a variable-frequency drive (VFD) on the power frequency motor can complete the accurate control and speed regulation of the motor, and improve the efficiency and accuracy of the motor. However, if not properly equipped and used, it may cause the following hazards:
...
|
|
Delta inverter repair steps
Delta inverters still have a certain influence in the industry, but even if the reputation is good, it will inevitably show some failures. Let's take a look.
...
|
|
Debugging Delta's inverter method
1. Acceleration and deceleration time
The acceleration and deceleration time is usually confirmed by the rise and fall of the frequency setting signal. In the commissioning of Delta inverters, it is often used to set a long acceleration and deceleration time according to the load and experience value, and the frequency rise rate of the motor must be constrained when it accelerates to avoid overcurrent. When slowing down, ...
|
|
The basic control loop of Delta's inverter
There are two fundamental circuits for communicating with external signals: analog and digital:
1. 4-20mA current signal loop (imitation); 1 - 5V/0 - 5V voltage signal loop (imitation).
2. Switch signal circuit, inverter start and stop command, forward rotation command, etc.
|
|
Selection of Delta power supply
There are many models of Delta's power supplies, and the currents and functions supported are also different, so how to choose?
VX Series Power Supplies.
VX270: Active PFC270w, but 12v is still small and can only be used at low power.
Active PFC and 12v output up to 276w at 300...
|
|
Precautions for long-term idle use of Delta inverter
If the inverter is to run the equipment again after being shelved for more than half a year, the probability of damage may be greatly increased due to many factors such as the placement environment, the service life of the inverter, and the load rate, and the failure usually presents the following problems:
1. After the equipment is powered on, it becomes ...
|
|