Elimination of inverter harmonics method – Reynolds

Create Date: 2024-8-30 12:03:23|Source: RENLE/RENOLDS

a. Add the internal impedance of the power supply of the inverterIn general, the internal impedance of the power supply equipment can play a role in buffering the reactive power of the DC filter capacitor of the inverter. This internal impedance is the short-circuit impedance of the transformer. When the power supply capacity is smaller than the inverter capacity, the internal impedance value is relatively large, and the harmonic content is smaller. The larger the power supply capacity relative to the inverter capacity, the smaller the internal impedance value and the greater the harmonic content. Therefore, when selecting the power transformer for inverter power supply, it is best to choose a transformer with large short-circuit impedance.

                               Elimination of inverter harmonics method – Reynolds

b. Device reactor The device reactor is actually the internal impedance of the power supply from the inverter added from the outside. A reactor or simultaneous device is installed on the AC side of the inverter or on the DC side of the inverter to suppress the harmonic current.

c. The rectifier part of the general inverter of the transformer multiphase operation is a 6-pulse rectifier, so the harmonics generated are larger. If the multi-phase operation of the transformer is used, if the two transformers combined with Y-△ and △-△ with a phase angle difference of 30° are combined to form a 12-pulse rectifier, the harmonic current can be reduced and harmonic suppression can be played.

d. Adjust the carrier ratio of the inverter to improve the carrier ratio of the inverter, which can effectively suppress the low harmonics.

e. The amplitude and phase of the harmonic current of the inverter can be detected by using the filter filter, and the current with the same amplitude and opposite phase as the harmonic current can be generated, and then the harmonic current can be effectively absorbed and eliminated.

More on that
The difference between the voltage type and the current type of inverter - Reynolds The difference between the voltage type and the current type of inverter - Reynolds

Energy storage elements are different, the voltage type energy storage element is a capacitor, and the current type is an inductor. In fact, the general inverter uses power electronic circuits, which is a process of communication to DC - DC energy storage - DC to communication. It is also often said that the rectifier link --〉 energy storage link --〉 inverter ring ...

Inverter installation and heat dissipation treatment - Reynolds Inverter installation and heat dissipation treatment - Reynolds

The inverter has power loss during operation and converts it into heat energy, which increases its own temperature. Roughly speaking, the power loss of every 1kVA inverter capacity is about 40W-50W. Therefore, when installing the inverter, it is necessary to consider the heat dissipation of the inverter, and how to run the inverter.

Introduction to soft starters and their relationship with frequency converters - Reynolds Introduction to soft starters and their relationship with frequency converters - Reynolds

When the high-power motor starts, the current is large, which will cause the grid voltage to be seriously shaken, in order to deal with this problem, the general requirements for speed regulation are not high, and the soft engine can be used to reduce the voltage and start. However, the drop in the starting current when the step-down is started will also make the starting torque drop significantly.

Frequency conversion cabinet external conduit wiring method - Reynolds Frequency conversion cabinet external conduit wiring method - Reynolds

When it is required to wiring outside the frequency conversion cabinet, it is generally necessary to use the conduit for wiring, which requires suitable mechanical pressure and unsuitable mechanical damage, moisture-proof and corrosion-resistant. Conduits include the following two wiring methods: 1. Kim ...

The inverter cannot adjust the frequency solution - Reynolds The inverter cannot adjust the frequency solution - Reynolds

In the course of inverter repairs, if there is no significant damage to the hardware and the maximum torque of the VFD is usually less than the torque of the load increase. It means that the load capacity of the frequency conversion speed control equipment has decreased significantly. So how do you deal with this? ...

Water pump inverter pressure adjustment method - Reynolds Water pump inverter pressure adjustment method - Reynolds

Water pump inverter pressure conditioning steps: 1. Open PID closed-loop control; 2. Close the pressure circuit; 3. Set the pressure feedback and set the given pressure; When the pump speed is changed, the outlet pressure can be changed. Adjust the operating frequency of the VFD. The higher the frequency, the higher the pump speed and the higher the pressure. About ...

Precautions for the use of frequency converters - Reynolds Precautions for the use of frequency converters - Reynolds

In order to ensure the safe, efficient and reliable operation of the inverter, the following keys should be grasped when using the inverter: 1) It is necessary for the grounding terminal of the inverter to be firmly grounded, so as to effectively press the radio frequency disturbance and enhance the reliability of the system: the frequency conversion speed regulation system is best to use independent grounding, grounding resistance...

Wiring of Reynolds frequency converters Wiring of Reynolds frequency converters

1 Main circuit wiring (1) Reynolds inverter three-phase AC input terminal (R, S, T) The power input terminal is connected to the three-phase AC power supply through the circuit breaker of the circuit breaker for line protection, regardless of the connection phase sequence. It should be noted here that the three-phase AC power supply is not ...

Characteristics of isolation transformer at the input end of AC power supply - Reynolds Characteristics of isolation transformer at the input end of AC power supply - Reynolds

a。 When the third harmonic and disturbance signals are severe, a barrier transformer can be used to eliminate the third harmonic and disturbance signals. b。 The use of barrier transformers can generate new neutrals and avoid the abnormal operation of equipment due to defective neutrals in the grid. ...

Inverter composition and various functions - Reynolds Inverter composition and various functions - Reynolds

Rectifier circuit: rectify 50HZ communication power into direct current. Frequency conversion circuit: The rectified direct current is inverted into a variable frequency communication current. Control part: control the frequency of communication electricity output by the inverter circuit. Maintenance circuit: maintenance and blockage of overcurrent and phase loss ...

Reynolds inverter code function description Reynolds inverter code function description

F09 second acceleration time 0.10 - 999.9sec; 5.0sec; △** The acceleration and deceleration parameters and the second acceleration and deceleration parameters are switched by terminal X3 (see F55); F10 second deceleration time 0.10 - 999.9sec; 5.0sec; △**Acceleration and deceleration parameters and the second acceleration and deceleration parameters are switched ...

Reynolds EPS emergency power supply routine maintenance Reynolds EPS emergency power supply routine maintenance

1. EPS the first use of the emergency power supply, the battery pack should be charged continuously for 48 hours after discharging protection; 2. EPS emergency power supply to keep the whole machine dry, clean, free of dust and foreign objects, wipe with a soft cloth after shutting down, and strictly ...

The heat dissipation method of Reynolds switching power supply The heat dissipation method of Reynolds switching power supply

1. Transfer heat pipes for heat dissipation. In many applications, the heat generated from the base steel plate of the power module is transferred through the heat transfer components to the distant heat pipe surface. In this way, the temperature of the base steel plate of the power module will be equal to the temperature of the heat pipe heat dissipation surface, the temperature of the heat transfer parts, and the temperature of the two contact ...

Reynolds drive soft troubleshooting Reynolds drive soft troubleshooting

1. Phenomenon (1) When starting from the beginning, it trips as soon as the speed is raised. This is a very serious phenomenon of overcurrent. The main reasons are: short circuit of load, stuck mechanical parts; The inverter module is damaged; The torque of the motor is too small. (2) Jump when powered on, this phenomenon generally can't ...

Advantages of the inverter vector control system - Reynolds Advantages of the inverter vector control system - Reynolds

Dynamic "fast response" DC motors are rectified constrained and excessively high di/dt is not allowed. The asynchronous motor is only constrained by the capacity of the inverter, and the multiple of the forced current can be very high, so the speed echoes quickly, generally reaching the millisecond level, which has surpassed the DC motor in terms of speed. At low frequencies ...

Classification and working principle of Reynolds inverter Classification and working principle of Reynolds inverter

Classification of Reynolds frequency converters: There are many classification methods for Reynolds inverters, which can be divided into voltage-type inverters and current-type inverters according to the classification of the main circuit operation method; According to the classification of switching methods, it can be divided into PAM operation.

Structural characteristics of Reynolds RHY series inverter governor Structural characteristics of Reynolds RHY series inverter governor

1. Technology: (PC or PLC) is used to make the equipment complete the intelligent constant pressure variable supply water supply according to the requirements of water supply and fire protection; 2. High efficiency and energy saving: the system can set the pressure according to the demand, and the system actively adjusts the speed of the pump and the number of pumps according to the set pressure, so that the equipment can run in ...

Safety standards for AC drives – Reynolds Safety standards for AC drives – Reynolds

International electrical safety standards: The requirements are in line with international electrical safety standards, such as CE standards in Europe and UL specifications in United States. These specifications specify the requirements for electrical safety functions, mechanical safety functions, EMC functions, etc. ...

Structural characteristics of Reynolds RHY series inverter governor Structural characteristics of Reynolds RHY series inverter governor

1. Advanced technology: (PC or PLC) is used to make the equipment complete the intelligent constant pressure variable supply water supply according to the requirements of water supply and fire protection; 2. High efficiency and energy saving: the system can set the pressure according to the demand, and the system can actively adjust according to the set pressure.

The factor that causes the breakdown of the inverter – Reynolds The factor that causes the breakdown of the inverter – Reynolds

1. Overpressure leads to brake pipe breakdown. The so-called overvoltage of the inverter refers to the fact that the inverter voltage formed due to various reasons exceeds the additional voltage, which is concentrated in the DC voltage of the inverter DC bus. The overvoltage alarm generally appears at the time of shutdown, and its main ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top