The next Gen family has added a new generation of intelligent laser photoelectric sensor W12L is now fully available, which continues the metal housing and IP69 protection level of the old product, and integrates the Bluepilot teaching assistance technology of W4F and W16/26.

New features such as fine light spot, extended detection distance, and multi-mode detection function enhance the stability and flexibility of the series. It is suitable for the detection needs of high-precision and small objects in various industries such as 3C, semiconductor, automobile assembly, machine tool processing, food packaging, etc.
New Arrivals | SICK new intelligent laser photoelectric sensor W12L
  Features:

Small light spot, high precision

The new generation of W12L spot can reach 0.17*0.1mm in size, which can be widely used in small object detection and thin sheet edge detection.

The new parallel spot is added, and the spot size is stable in the horizontal direction within the detection distance. Background suppression can reach 0.2mm at best, which is suitable for a variety of high-precision inspection applications.
New Arrivals | SICK new intelligent laser photoelectric sensor W12L
  W12L has a spot size of 0.17*0.1mm (100mm)

Dramatically increased detection distance and sensitivity

The new generation of W12L has improved the problem of insufficient detection distance of the conventional laser-type photoelectric sensor, and has added a long-range type and a high-sensitivity type.

The long-range model can detect objects with an angle of up to 850 mm, the high-sensitivity type can detect objects with an angle of 1.2 m, and even black objects can reach a detection distance of 1 m.

The new All-In-One multi-mode photoelectric sensor

The WTM12L incorporates a variety of detection modes that can be easily selected by the customer via the BluePilot interface and the integrated teach-in button.

Detection modes include:

1) Background suppression mode

2) Foreground suppression mode

3) Two-point teaching mode

4) Independent double switching

5) Window mode

6) High sensitivity mode

7) Ranging mode
New Arrivals | SICK new intelligent laser photoelectric sensor W12L
  Multi-modality – multiple benefits

Reduce the complexity of model selection: One photoelectric is suitable for multiple scenarios.

Reduced excess inventory: There is no need to have a large number of different sensors for each project.

Intelligent sensing, flexible production: Communication via IO-Link enables parameterization, digital twinning, real-time monitoring, and predictive maintenance of optoelectronics.

Smart Sensing

All the new generation of W12L laser sensors are equipped with IO-Link communication and can be connected to the SIG200 and SIG350, which can provide the sensors with the advantages of parameter visualization, flexible reading and writing, and condition diagnosis and predictive maintenance. A new Industry 4.0 sensor solution has been formed.
New Arrivals | SICK new intelligent laser photoelectric sensor W12L
  Application scenarios

Detection of small objects such as screws and nuts in the assembly industry
New Arrivals | SICK new intelligent laser photoelectric sensor W12L
  Small hole detection in electronics and machine tool processing
New Arrivals | SICK new intelligent laser photoelectric sensor W12L
  Tobacco and food processing industries

Detection of rods and small objects
New Arrivals | SICK new intelligent laser photoelectric sensor W12L
  Food filling machine material line

Irregular objects are detected in place
New Arrivals | SICK new intelligent laser photoelectric sensor W12L
  The main model
New Arrivals | SICK new intelligent laser photoelectric sensor W12L

More on that
Sick Sensors – An Introduction to Seven Common Sensors Sick Sensors – An Introduction to Seven Common Sensors

1. Physical sensor: A physical sensor is a sensor that detects a physical quantity. It is a device that uses certain physical effects to convert the measured physical quantity into a signal in the form of energy that can be easily processed. There is a definite relationship between the output signal and the input signal. The main physical ...

Sick Sensors – What are the precautions for the use of load cells? Sick Sensors – What are the precautions for the use of load cells?

1. The signal cable of the sensor should not be arranged in parallel with the strong current power line or control line (for example, do not place the sensor signal line in the same pipe as the strong power line and the control line). IF THEY MUST BE PLACED IN PARALLEL, THEN THE DISTANCE BETWEEN THEM SHOULD BE KEPT AT LEAST 50CM, AND THE SIGNAL ...

Sick sensors – how to work and how to use color mark sensors Sick sensors – how to work and how to use color mark sensors

How the color mark sensor works The color mark sensor is actually a reverse installation, the light source is perpendicular to the target object device, and the bearer is biased towards the device at an acute angle to the object, so that it only detects the scattered light from the target object, and then prevents the sensor from directly bearing the reflected light, and can make ...

How to solve the error of function block? How to solve the error of function block?

The reader always gives an error, which can be found in the function block usage documentation. 01. How to download and view The public information of most of Sea's products can be downloaded from the official website without login, please find it in the download area at the bottom of the product homepage. For example, we make ...

How to adjust the SICK UM18-51112 sensor How to adjust the SICK UM18-51112 sensor

Preparation tools: calibrator to change the distance of the ultrasonic sensor, special regulator and special power supply. Disconnect the power supply: Disconnect the ultrasonic sensor from the controller and prepare it for commissioning. Commissioning time: The commissioning time can be adjusted to any time to meet the needs of personalization.

Introduction to the functional characteristics of SICK's safety switches Introduction to the functional characteristics of SICK's safety switches

1. When the load exceeds the action current, the circuit will be automatically cut off. 2. After the circuit is automatically cut off, the panel indicator light is on, which is convenient for judging the fault part. 3. After troubleshooting, press the red button at the bottom of the panel to restore the normal power supply. 4. For other reasons, the shell ...

Adjustment method of the Sick WFS3-40N415 sensor Adjustment method of the Sick WFS3-40N415 sensor

(1) Automatic calibration: When the workpiece enters the sensitive area of the probe, hold down the "SET" button for 3 seconds, and the sensitivity value will be set and displayed in green. (2) Two-point calibration: When the workpiece does not enter the sensitive area, press and hold the "SET" button for three seconds.

The range of applications for Sick sensors The range of applications for Sick sensors

1. Detect the torque in the working process of various machining centers and automatic machine tools. 2. Detect the load torque and input power of reducer, fan, pump, mixer, winch, propeller, drilling machinery and other equipment. 3. Detection of generators, electric motors, internal combustion engines...

A simple explanation and how to use the SICK color scale sensor A simple explanation and how to use the SICK color scale sensor

The SICK color mark sensor detects a wide range of labels, even if there are subtle differences in the background color, and the processing speed is fast. Automatically adapts to wavelength and is able to detect small differences in grayscale values, regardless of the mixed color of the label and background. SICK color code ...

Sick 3D vision gluing application case in shoe soles Sick 3D vision gluing application case in shoe soles

Traditional sole gluing needs to be done manually, and this process generally has a high temperature and fast toxicity volatilization. However, with the development of Industry 4.0, outdated equipment, rising costs, poor production environment, and shortage of personnel in this type of work have become important reasons for the upgrading and transformation of this process. SICK in partnership ...

Sick Sensors – A detailed introduction to the principles of the five common pressure sensors Sick Sensors – A detailed introduction to the principles of the five common pressure sensors

1. Piezoelectric pressure sensor Based on the piezoelectric effect, electrical components and other machinery are used to convert the pressure to be measured into electricity, and then perform related measurement work. Piezoelectric sensors can only be used for dynamic measurements. Host...

SICK was unveiled at the 12th China Online Analytical Instrument Application and Development SICK was unveiled at the 12th China Online Analytical Instrument Application and Development

On November 13, 2019, the "12th China Online Analytical Instrument Application and Development International Forum and Exhibition" jointly organized by the Analytical Instrument Branch of China Instrument Industry Association and the Analytical Instrument Branch of China Instrument and Control Society was grandly opened at Nanjing International Exhibition Center. As a full ...

Sick Sensors – the principle and practical application of color mark sensors Sick Sensors – the principle and practical application of color mark sensors

Principle: Contrast sensors are often used to detect spots on specific color marks or objects, and they are used to detect color marks by comparing them to non-color mark areas, rather than directly measuring color. The color mark sensor is actually a reverse device, where the light source is mounted perpendicular to the target object, and the receiver is connected to the ...

Sick Sensors – An introduction to the working principle of common pressure sensors Sick Sensors – An introduction to the working principle of common pressure sensors

1. Piezoresistive pressure sensor Resistive strain gauges are one of the main components of piezoresistive strain transducers. The working principle of metal resistance strain gauge is the phenomenon that the resistance value changes due to mechanical deformation due to the strain resistance adsorbed on the base material, which is commonly known as the resistance strain effect. ...

Sick intelligent sensors help the intelligent transformation of the pharmaceutical industry Sick intelligent sensors help the intelligent transformation of the pharmaceutical industry

With the obvious trend of population aging and the innovation and development of the medical and pharmaceutical industry, it can be expected that the demand for pharmaceutical products in China will continue to grow rapidly, and it is estimated that the industry scale will reach 2.15 trillion yuan by 2024. The huge market size also means more fierce market competition, plus ...

Sick Sensors – How to deal with failures in AGC displacement sensors Sick Sensors – How to deal with failures in AGC displacement sensors

(1) Measure the clock signal and data signal of the displacement sensor of 4 hydraulic cylinders, the clock signal is about 2.8V DC and 0.123V AC; The data signals are all about 2.8V DC and 0.245V AC. From this, it can be judged that the PLC clock and MTS data bit transmission and reception pulse loops are normal ...

Sick Sensors – the working principle and failure analysis of displacement sensors Sick Sensors – the working principle and failure analysis of displacement sensors

Linear displacement sensors work on the same principle as a sliding rheostat and are used as voltage dividers, which represent the actual position of the measured position with a relative output voltage. There are the following requirements for the work of this device: First, if the electronic ruler has been used ...

Adjustment method of the Sick WFS3-40N415 sensor Adjustment method of the Sick WFS3-40N415 sensor

(1) Automatic calibration: When the workpiece enters the sensitive area of the probe, press and hold the "SET" button for 3 seconds, and the sensitivity value will be set and displayed in green. (2) Two-point calibration: When the workpiece does not enter the sensitive area, hold and hold the "SET" button for three seconds, there is a ...

Parameter settings for the Sigg distance sensor Parameter settings for the Sigg distance sensor

1. Set to "Surface" to measure the distance from the first surface within the sensor's detection range. This setting is available for all sensor heads. 2. Set to Glass Thickness to measure the distance from the front to the back of a transparent object, such as glass. This means that it has been measured with the sensing ...

Sick Sensors – Precautions for the use of displacement sensors Sick Sensors – Precautions for the use of displacement sensors

1. There are many types of displacement sensors, and the measurement accuracy, service life, response frequency and applicable occasions of sensor products designed with different principles will be slightly different. Appropriate displacement sensor products should be selected according to the on-site installation and measurement requirements. 2. The measurement range of the displacement sensor is one ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top