SICK was unveiled at the 12th China Online Analytical Instrument Application and Development

Create Date: 2024-8-30 12:03:23|Source: SICK/Sick

On November 13, 2019, the "12th China Online Analytical Instrument Application and Development International Forum and Exhibition" jointly organized by the Analytical Instrument Branch of China Instrument Industry Association and the Analytical Instrument Branch of China Instrument and Control Society was grandly opened at Nanjing International Exhibition Center. As the world's leading provider of sensor and analysis system solutions, SICK presented its presence at the conference with the theme of "Application Solution for Online Monitoring of Ship Exhaust Emissions".
                                  SICK was unveiled at the 12th China Online Analytical Instrument Application and Development
In recent years, the International Maritime Organization (IMO) has continuously issued corresponding regulations and standards to control sulfur emissions from ships in order to reduce ship exhaust emissions. According to the 2017 IMO meeting, the global 0.5% sulfur limit will be officially implemented from January 1, 2020, so the continuous emission monitoring technology of ship exhaust gas has become a hot issue at present.

The MARSIC series of marine exhaust gas monitoring systems from SICK is an innovative solution for reliable emission measurement in accordance with MARPOL Annex VI and MEPC.259(68). MARSIC is certified by DNV GL, ABS, NK, BV, LR, CCS, KR classification societies. MARSIC measures SO2 and CO2 not only after scrubbers (desulfurization units), but also before and after SCR in denitrification units, and can measure NO and NO2 separately. In addition, MARSIC can be used for process monitoring, e.g. NH3 escape in SCR systems, CH4 escape in LNG and dual-fuel engines.

As a leader in marine emission monitoring technology, SICK offers two different MARSIC systems for the monitoring of marine emissions. The modular design of the MARSIC200 is impressive, and the MARSIC300 is an all-in-one system. Since it is a system designed specifically for marine applications, the fast and convenient service relieves the worries of system operation.

In China, SickMaker China has become a veritable industry leader as a manufacturer of various types of online emission monitoring technologies. At the same time, Sick Merick China, with its innovative technology and proven manufacturing processes, ensures that it continues to provide future-proof solutions, even in the face of increasing environmental and safety requirements.

More on that
Sick's 3D vision product Ruler3000 series has been expanded with two new members Sick's 3D vision product Ruler3000 series has been expanded with two new members

Two new members of the Ruler3000 family of Sick 3D vision products have been added, named Ruler3120 and Ruler3008.   The new 3D vision sensor solution Ruler3000 from SICK is suitable for a wide range of industrial applications and is characterized by its high speed and image quality. 3D Visual Transmission ...

Sick sensors – the three major functions of photoelectric sensors Sick sensors – the three major functions of photoelectric sensors

First, the transmission effect Through the photoelectric sensor, it can be very good to complete the transfer between the media, which is a very popular way of action in many industrial fields and enterprises, because some energy can not be transmitted manually and can only be reached by machines.

Sick's 3D vision product Ruler series has been newly upgraded! Sick's 3D vision product Ruler series has been newly upgraded!

Recently, Sick's 3D vision product Ruler series has been newly upgraded! The new products Ruler3002, Ruler3004 and Ruler3010 are officially available today!   01. Product characteristics • Contour point upgrade: up to 3200 Data points/Profile • Ultra-high scanning speed ...

An introduction to the three common types of photoelectric sensors An introduction to the three common types of photoelectric sensors

1. Photoelectric switch sensor The occlusion between the transmitter and receiver is used to detect states such as motion, object presence, or object position. When the measured object passes through the occlusion beam, the intensity of the light signal received by the receiving head changes, which in turn triggers the switching signal. Photoelectric switch ...

Sick Sensors - Precautions for the use of linear displacement sensors Sick Sensors - Precautions for the use of linear displacement sensors

1. If the electronic ruler has been used for a long time, and the seal has been aged, and there are many impurities mixed with it, and the water mixture and oil will seriously affect the contact resistance of the brush, which will make the displayed numbers keep jumping. At this time, it can be said that the electronic ...

Sick Sensors - Introduction to the advantages of RTD sensors Sick Sensors - Introduction to the advantages of RTD sensors

(1) High measurement accuracy; The reason why RTD sensors have high measurement accuracy is mainly because the resistance temperature characteristics of some materials are stable and reproducible. Secondly, compared to thermocouples, it does not have the problem of reference end error; (2) It has a large measurement range, especially in low temperatures; ...

Sick Deep Learning SensorApp Intelligent Inspection Plus released Sick Deep Learning SensorApp Intelligent Inspection Plus released

Based on the InspectorP series of Sick 2D smart cameras, the deep learning SensorApp Intelligent Inspection Plus was officially launched, adding "Anomaly detection" and "Classification ...

Sick Sensors – the working principle and failure analysis of displacement sensors Sick Sensors – the working principle and failure analysis of displacement sensors

Linear displacement sensors work on the same principle as a sliding rheostat and are used as voltage dividers, which represent the actual position of the measured position with a relative output voltage. There are the following requirements for the work of this device: First, if the electronic ruler has been used ...

How to adjust the SICK UM18-51112 sensor How to adjust the SICK UM18-51112 sensor

Preparation tools: calibrator to change the distance of the ultrasonic sensor, special regulator and special power supply. Disconnect the power supply: Disconnect the ultrasonic sensor from the controller and prepare it for commissioning. Commissioning time: The commissioning time can be adjusted to any time to meet the needs of personalization.

New Arrivals | Sick DLS40 incremental encoder New Arrivals | Sick DLS40 incremental encoder

As we all know, incremental encoders are used to monitor rotational speed or position, and are widely used in all kinds of automated machinery. With the continuous development of the industrial control industry and the continuous change of product demand, SICK has launched a more cost-effective and cost-effective small incremental encoder market in the large and competitive small incremental encoder market.

Sick Sensors – The lead method for RTD sensors Sick Sensors – The lead method for RTD sensors

1. Two-wire system: the way to connect a wire at both ends of the thermal resistance to draw out the resistance signal is called the two-wire system: this lead method is very simple, but because there must be a lead resistance r for connecting the wire, the size of R is related to the material and length of the wire, so this lead method is only applicable to ...

Sick Sensors – Troubleshooting Methods for Photoelectric Sensors Sick Sensors – Troubleshooting Methods for Photoelectric Sensors

1. The pressure goes up, the output of the transmitter does not go up to this situation, you should first check whether the pressure interface is leaking or blocked, if you admit that it is not, check the wiring method and check the power supply, if the power supply is normal, then simply pressurize to see if the output changes, maybe observe whether the zero position of the sensor has an output, if there is no ...

Sick has launched its latest MDA Vision system Sick has launched its latest MDA Vision system

In the current era of rapid economic development, logistics is known as the "blood" of the national economy, although the early Chinese logistics industry started late, with the continuous improvement of the system, the rapid development of high and new technology, now the logistics industry has become a social and economic bridge and link. Among them, the data flow is ...

What are the relevant applications for Sick sensors – ultrasonic sensors? What are the relevant applications for Sick sensors – ultrasonic sensors?

Main applications: Ultrasonic sensing technology is used in different aspects of production practice, and medical application is one of its most important applications. The application of ultrasound in medicine is mainly to diagnose diseases, and it has become a clinical...

Sick 3D cameras enable high-speed inspection of automotive bearings Sick 3D cameras enable high-speed inspection of automotive bearings

Automobile is one of the pillar industries of the national economy, with the rapid development of China's automobile industry, the pursuit of higher detection speed is gradually reflected. The automobile steering shaft is an important part of the automobile power system, the upper part is fixedly connected with the steering wheel, and the lower part is connected with the steering gear; Its performance of ...

Sick Sensors – the working principle and application of color sensors Sick Sensors – the working principle and application of color sensors

What are the applications of color sensors? 1. Discrete photodiode with color filter The traditional color sensing method uses a structure in which three to four photodiodes are combined on a single chip, and red, green, and blue filters are placed on the surface of the photodiodes. An independent ...

Sick Sensors – Installation Requirements for RTD Sensors Sick Sensors – Installation Requirements for RTD Sensors

1. In order to have sufficient heat exchange between the measuring end of the RTD and the medium to be measured, the location of the measuring point should be reasonably selected, and the installation of RTD near the valve, elbow, pipe and equipment should be avoided as much as possible. 2. The thermal resistance with a protective sleeve has heat transfer and heat dissipation loss, in order to reduce the ...

How to debug and use Sick fiber optic sensors How to debug and use Sick fiber optic sensors

1. Basic composition The appearance of this series of fiber optic sensors is basically composed of the following parts, from left to right: (1) SET button, this button can be used for sensitivity setting. The basic principle of this sensor is: through the induction of the refractive index of different media by the fiber optic probe, ...

Scope of application for SICK sensors Scope of application for SICK sensors

1. Detect the torque in the working process of various machining centers and automatic machine tools. 2. Detect the load torque and input power of reducer, fan, pump, mixer, winch, propeller, drilling machinery and other equipment. 3. Detection of generators, electric motors, internal combustion engines...

Presentation of the Sick Multi Physics Box sensor Presentation of the Sick Multi Physics Box sensor

advantage Processes are more transparent and machine downtime is less The Multi Physics Box enables Condition Monitoring. Whether it's motors, pumps, conveyor belts or fans – the measured values of temperature, vibration behavior and shock show the phase...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top