Schneider miniature circuit breakers are commonly used in C65, C120, EA9, INT125 and other products.
Parameter differences:
N -------- breaking ability, N is 6000A, H is 10000A, L is 15kA
C -------- trip curve, B is electronic maintenance, C is power distribution maintenance, and D is power maintenance
20A------ rated current, 1, 2, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63A
2P ------- number of poles, there are 1, 2, 3, and 4 poles
VE ------- residual current accessories, including VE, VEG, VM, VEA, VM, VM is electromagnetic
30mA----- residual operating current, 30, 100, 300mA
SD ------- optional accessories, including MX, OF, MN, MV, SD, Tm, ATm, of which SD is the alarm auxiliary contact.
|
More on that
|
Analysis of 10 reasons for frequent tripping of Schneider leakage switches
1. Defective device
If the lead wire of each pile head is not firmly connected and loosened for a long time, it will cause the pile to heat and oxidize, burn out the outer insulation of the wire, and announce sparks and burnt smell, resulting in undervoltage of the line and air switch action.
2. Leakage switch with ...
|
|
Fault check steps for frequency converters - Schneider frequency converters
1. Check whether the appearance of the inverter is in good condition, including whether the indicator light is running normally, whether the task control function of the operation panel is complete, and carefully observe the appearance of the inverter in the operating state, and do the corresponding recording work; When repairing the inverter, check whether the voltage value and current value exceed the allowable ...
|
|
Schneider Intermediate Relay Model Letter Meaning
RXM: Schneider's miniature center relay
The first 2: indicates the number of contacts, and the normally open contact is 2
LB: Indicates that the product has LED light
The second 2: indicates the number of contacts, and the normally closed contacts are 2
BD: Indicates that the supply voltage used is DC 24V
...
|
|
Automatic control instrument construction content and procedures - Schneider
1. Construction preparation. Including the preparation of operating conditions (construction skills documents and detailed planning documents), construction organization planning, equipment list, data budget, and list of machined parts;
2. Cooperate with civil engineering majors to do a good job of embedding, ...
|
|
Schneider instrumentation maintenance precautions
1. When assembling and adjusting the appearance, the original position should be recorded for rehabilitation.
2. When repairing the appearance of precision instruments, if you accidentally bounce small parts away, you should first determine the position where you can fly down.
|
|
Schneider ATV312 inverter failure
1. OLF is motor overload.
Possible reasons: 1. Triggered by high motor current. 2. The value of the [cold stator resistance] (rSC) parameter is wrong.
Corrective measures: 1. Check the [Motor Thermal Current] (ItH) setting of the motor thermal maintenance function and check the motor load. Wait...
|
|
Factors influencing the differential thermal analysis of instrumentation - Schneider
The operation of differential thermal analysis is simple, but in practical work, it is often found that the same sample is measured on different instruments, or different measurements are measured on the same instrument, and the results of the differential thermal curve of industrial electrical appliances are different. The high temperature, shape, area, and size of the peaks will all change. ...
|
|
Frequency converter control motor leakage solution - Schneider
Because the current at the input and output ends of the inverter contains high-frequency components, the leakage current formed by the high-frequency components when the inverter is driven is greater than that when the grid power supply is supplied. Because there are many varieties of circuit breakers, in some cases, even the inverter wires and motors ...
|
|
Schneider AC contactor precautions
There are many series of contactors: LC1-SK series: below 6ALC1-K series: 6A-16ALC1-D series: 9A-150ALC1-F series: 115A-800ALC1-B series: 750A-1800A
When installing, it should be in accordance with the regulations...
|
|
Instrumentation mechanical equipment system - Schneider
1. Power system:
The wire and cable products selected in the power system mainly include overhead bare wires, busbars (busbars), power cables (plastic cables, oil-paper power cables (fundamentally replaced by plastic power cables), rubber cables, overhead insulated cables), branch cables (replacing part of the busbars), ...
|
|
Schneider electrical circuit control fault range
In general, depending on the phenomenon of equipment problems, the scope of the problem can be roughly confirmed as follows:
1) All button functions fail, and there is a high possibility of power supply or fuse problems.
2) Some buttons are invalid, and some of the buttons are functioning normally ...
|
|
Safety PLC is different from ordinary PLC
A safety PLC differs from conventional PLCs in that it needs to be certified for safety by a third-party professional organization and meet stringent international standards for safety and reliability. There is a need for a thorough systematic approach to the planning and testing of safety PLCs. TUV*** in Germany and FM*** in United States ...
|
|
Schneider inverter maintenance power settings, waveform test problems
1. After the inverter is repaired, the power number needs to be modified, don't forget it
Generally, an inverter corresponds to a power number (also known as the number of horsepower), for example, a 75 kilowatt inverter is set under heavy load, and 100 kilowatts is set under light load. In this way, the customer will not use it to present ...
|
|
Knowledge of Schneider Lexium32 servo motors
Schneider Lexium32 servo motor new generation servo release enriches Schneider Electric's high-end product line, its outstanding product functions, sensitive openness and user-friendly planning will better meet the high functional and safety requirements of industrial customers. In China's industrial production is increasingly moving towards energy-saving ...
|
|
Features of Schneider explosion-proof inverter box
1. Aluminum alloy shell or steel plate welding, surface spraying;
2. Built-in inverters, circuit breakers, signal lights and other components produced by domestic or Schneider and other companies;
3. It is mainly adjusted by changing its output frequency to adjust the speed of ordinary three-phase asynchronous motor, so as to reach the production process.
|
|
Schneider inverter motor control mode
Fundamentals of magnetic flux vector manipulation
The control of a three-phase asynchronous motor is much more messy than that of a DC motor because the current, voltage, induced potential, magnetic flux, etc., of the stator and rotor are all alternating.
However, the stator winding of the three-phase asynchronous motor is a symmetrical three-phase winding, which exerts a ...
|
|
Methods to reduce the interference of Schneider inverters themselves
When there are high-frequency impact loads such as welding machines, electroplating power supplies, electrolytic power supplies, or slip ring power supply near the power supply system of Schneider inverter, the inverter itself is simply protected due to interference. It is recommended that users choose the following methods:
...
|
|
How to prevent counterfeiting from Schneider switch sockets
1. Logo
The logo of the product is a status symbol, so it will be made very exquisitely. Schneider switches are also very careful in the production of logo, each letter is like an independent work of art, and let's see that the letter "A" is flat and wide. But the imitation ...
|
|
Pressure Reducing Valve in Instrumentation – Schneider
A kind of pressure reducing valve in instrumentation refers to a kind of equipment used to control the pressure value. Pressure reducing valves are usually used in water-related categories, because from the perspective of the transmission medium, the transmission medium of the equipment is mainly water, but we all know that water is a thing that will ...
|
|
Precautions for the installation of low-voltage electrical appliances - Schneider
1. Low-voltage electrical appliances should be equipped in a place without violent vibration, and should have an appropriate height from the ground. It is necessary to connect the power cord such as the knife switch and the load switch to the fixed contact, and it is forbidden to hang the power cord on the knife switch.
2. Low-voltage ...
|
|