Automatic control instrument construction content and procedures - Schneider

Create Date: 2024-8-30 12:03:23|Source: Schneider/Schneider

1. Construction preparation. Including the preparation of operating conditions (construction skills documents and detailed planning documents), construction organization planning, equipment list, data budget, and list of machined parts;

                                 Automatic control instrument construction content and procedures - Schneider

2. Cooperate with civil engineering majors to do a good job of pre-embedding and reserving operations;

3. Cooperate with process equipment, pipelines and other professionals to determine the location of measurement and control points and do a good job of primary (source) components;

4. Production and device positioning of various metal brackets (surface equipment brackets, pipeline brackets, cable tray brackets), bridge frames (slot boxes, trays, ladder frames), enlarged tubes, outer dials (boxes, cabinets), operating tables, etc., and assist in the production of containers and processed parts;

5. Appearance out of the warehouse, unpacking inspection and single adjustment;

6. On-site detection of the appearance, control of the outdoor surface device in place, piping, wiring, calibration and wiring of the outer surface panel cabinet, and preparation of line resistance;

7. Laying of impulse pipelines and heat tracing pipelines, valve grinding and devices, laying of surface air source pipes and pneumatic pipelines, pressure testing and leak testing;

8. Electrical maintenance pipe, flexible pipe device, cable, compensation wire laying, cable insulation experiment and wire finding, grounding system device, grounding resistance test;

9. Equipment insulation, pipeline anti-corrosion and heat insulation;

10. Debugging of automatic control appearance system: joint debugging of detection system, control system, interlocking and emergency parking system (ESD) and decentralized control system (DCS) to ensure that the action is correct;

11. Purging, pressure testing and project sweeping of the professional system of cooperative process;

12. Cooperative process monomer commissioning and feeding commissioning;

13. Delivery, acceptance, and delivery.

More on that
The difference between Schneider UPS and EPS power supply The difference between Schneider UPS and EPS power supply

1. Different safety standards UPS is mainly used to protect users' equipment or business from economic loss, and its product technical certification mainly includes Thiel certification, CQC certification, etc. The development of EPS power supply stems from the sudden failure of the power grid, in order to ensure the power safety and fire linkage needs, it can be supplied immediately.

Features of Schneider's different PLC series Features of Schneider's different PLC series

Schneider PLC series mainly includes: Schneider NEZA PLC (Schneider TSX08 series); Schneider Quantum PLC (Schneider 140 series); Schneider Micro PLC (Schneider TSX37 series); Schneider Premium PLC (Schneider TSX...

Maintenance of Schneider circuit breakers Maintenance of Schneider circuit breakers

In order to keep the main Schneider circuit breaker in excellent operating condition, it is necessary to strengthen the maintenance management. 1. Insist that the air is moist or unclean, and the pipes are not clean, may have the following consequences: (1) The wet gas is decomposed into mixed gases such as hydrogen and oxygen under the action of electric arc, which damages the ...

"Five Ways" to Solve Life Sciences Industry Challenges – Schneider "Five Ways" to Solve Life Sciences Industry Challenges – Schneider

In life sciences careers, equipment performance is critical to ensuring business continuity and useful production time. The main challenges faced by the industry include: maintaining the positive impact of environmental parameters on product quality, managing multiple systems in a "siloed" state, and using existing infrastructure sensitively and efficiently.

Schneider low-voltage circuit breaker selection method Schneider low-voltage circuit breaker selection method

1. Determine the type and maintenance situation of Schneider circuit breaker according to the maintenance requirements of the line, and determine the selection of frame type, device type or current limiting type. Generally speaking, the short-circuit current breaking ability of Schneider frame circuit breaker is larger and larger than that of device type. Usually, the branch line chooses ...

Schneider instrumentation accuracy Schneider instrumentation accuracy

It refers to the degree to which the average value measured repeatedly under certain test conditions is consistent with the true value, which is indicated by error. It is used to indicate the magnitude of the error in the system. In practice, control tests are generally carried out with standardized substances or normative methods, and when there are no standardized substances or normative methods, it is often used to add ...

How Schneider contactors work How Schneider contactors work

1. Contactor refers to an electrical appliance that uses a coil to flow through an electric current to generate a magnetic field, so that the contact is closed, and then the load can be controlled. Because it can quickly block the main circuit and frequently connect the equipment with high-current control circuits, it has been widely used in electrical engineering.

Schneider medium-voltage inverters focus on energy saving Schneider medium-voltage inverters focus on energy saving

Because the impact of foreign electrical products on domestic electrical equipment is relatively large, now Schneider inverter equipment occupation is facing a big technical promotion, taking inverter as an example, the national connotation of inverter shopping mall domestic brand and foreign brand, regardless of technology, processing and manufacturing, industrial design and other aspects are still ...

How to choose the Schneider ATV71 and the meaning of the letter How to choose the Schneider ATV71 and the meaning of the letter

The Schneider inverter model generally reflects the rated voltage, rated power, and load requirements of the inverter (heavy load is still light load type). Here are 2 examples: Example 1: Schneider inverter model: ATV71HD11 ...

Features of Schneider elliptical gear flowmeter Features of Schneider elliptical gear flowmeter

Elliptical gear flowmeter (also known as displacement flowmeter, gear flowmeter), classified as a positive displacement flowmeter, is a class with high accuracy in the flow surface. It uses a mechanical measuring element to continuously cut the fluid into a single known volume part, and according to the measuring chamber, it is repeated and repeated.

Schneider lamellar relays Schneider lamellar relays

Schneider RSL Thin Sheet Relay, as a member of the large family of ZelioRelay series relays, RSL Thin Plate Relays will be committed to saving users space and time in the device, and improving the stability of the system. Schneider Electric Vice President of China, Head of Industrial Division, Xiu De...

Advantages and disadvantages of closed busbars compared with open busbars - Schneider Advantages and disadvantages of closed busbars compared with open busbars - Schneider

The advantages of closed busbars over open busbars are: 1) Closing the bus duct can reduce the grounding fault, avoid the short circuit between phases, basically eliminate the grounding defect caused by external moisture, dust and foreign objects, and improve the continuity of generator operation. 2) Eliminate ...

Electrical Control Line Fault Analysis Method - Schneider Electrical Control Line Fault Analysis Method - Schneider

1) Survey and research method. The investigation and research method is to "see", "listen", "smell", "touch" and "ask" to understand the significant faulty phenomena; After visiting the operator, understand the cause of the problem; A common way to help find faults after consulting others or consulting information ...

Where the inverter filter is suitable - Schneider Where the inverter filter is suitable - Schneider

1. LC filter LC filter is suitable for occasions with low requirements for harmonic content, and a good LC filter can control the distortion rate at 8-10%; 2. Harmonic filter This filter is suitable for harmonic ...

Schneider's small PLC part model Schneider's small PLC part model

  Schneider has M100/M200 for small programmable controllers, and M340 and M580 for medium and large programmable controllers The compact M100 model is available in TM100C24RN, TM100C32RN, and TM100C40RN. Small M200 ...

Schneider ATV71 selection and letter meaning Schneider ATV71 selection and letter meaning

The type of Schneider inverter generally reflects the rated voltage, rated power, and load requirements of the inverter (heavy or light load). Here are two examples: Example 1: Schneider Inverter Type: ATV71HD11N ...

How to identify the quality of an inverter – Schneider How to identify the quality of an inverter – Schneider

Nowadays, the function of domestic inverters is becoming more and more mature, with a wide variety and dazzling. Many brands have been tested by the market, but there are also some brands that have been imitated and counterfeited to disrupt the market. One of the major characteristics of domestic brands is that they are both like domestic brands and imported brands. The brand's ...

Schneider turbine flowmeter selection considerations Schneider turbine flowmeter selection considerations

1. According to the requirements of measurement intention: It is required to select the unit with instantaneous flow rate or cumulative flow rate (cumulative flow), the unit of flow display, measurement accuracy, repeatability, linearity, flow scale and scale, measurement temperature, pressure loss, temperature and pressure compensation, output signal characteristics and echoes.

The UPS boot panel does not show that the UPS is not working - Schneider The UPS boot panel does not show that the UPS is not working - Schneider

Problem: After the UPS is turned on, there is no display on the panel, and the UPS does not work Problem analysis: Judging from the problem phenomenon, the problem lies in the mains input, the battery and the mains detection part and the battery voltage detection loop: 1. Check ...

Introduction to Schneider PLC series Introduction to Schneider PLC series

1. LMC058 & LMC078 Modicon Motion Controller Product Information Faster machine planning The motion controller uses the same programming software as the PLC; Custom-made utility blocks for complex use; Dedicated motion function library for programming, debugging, and diagnosis ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top