Schneider Lexium32 servo motor new generation servo release enriches Schneider Electric's high-end product line, its outstanding product functions, sensitive openness and user-friendly planning will better meet the high functional and safety requirements of industrial customers. Under the general trend of China's industrial production increasingly moving towards energy conservation and efficiency, Schneider Electric's servo skills can bring quantifiable energy-saving benefits to Chinese users, and will play an important role in improving the productivity and competitiveness of enterprises.
Schneider Lexium32 servo motor follows the easy-to-use planning concept, Lexium32 series servo has the advantages of simple device, convenient commissioning, excellent function, sensitive and open external interface, etc., can be successfully used in hot stamping machine, packaging machine, filling machine, and stacking manipulator and other equipment, with the industry's first-class function and planning, the product is sensitive and open, and the product use is also very simple.
Scope of use:
packaging machinery; printing machinery; Material handling equipment ; textile machinery; Machine tools (metalworking); rubber and plastic machinery ; Electronic Equipment
Functional depiction:
100… 120 V single phase, 0.15 kW to 0.8 kW
200… 240 V single phase, 0.3 kW to 1.6 kW
380… 480 V three-phase, 0.4 kW to 7 kW
The Lexium 32 is available with three servo drives: compact, enhanced, and modular
It has two servo motors: BMH medium inertia and BSH low inertia
4 times the peak current, 1600HZ speed loop echo, excellent self-tuning function
The drive is compatible with 7 operating interfaces
Color-coded pluggable terminals allow data to be updated with memory cards and new drives can be replaced in less than 3 minutes
The drivers can be side-by-side, simple daisy-chained, and can be powered by a common DC bus
The driver has built-in safety functions and brake control functions
The motor adopts high-precision encoder and high insulation grade metal plug. |
More on that
|
The UPS boot panel does not show that the UPS is not working - Schneider
Problem: After the UPS is turned on, there is no display on the panel, and the UPS does not work
Problem analysis: Judging from the problem phenomenon, the problem lies in the mains input, the battery and the mains detection part and the battery voltage detection loop:
1. Check ...
|
|
Schneider EZD series molded case circuit breaker is recommended
Create a high-quality circuit breaker for secondary power distribution
EZD molded case circuit breaker is a product series of molded case circuit breakers specially designed for secondary power distribution, especially suitable for secondary power distribution, civil construction market and mechanical and electrical market.
|
|
Frequency converter control motor leakage solution - Schneider
Because the current at the input and output ends of the inverter contains high-frequency components, the leakage current formed by the high-frequency components when the inverter is driven is greater than that when the grid power supply is supplied. Because there are many varieties of circuit breakers, in some cases, even the inverter wires and motors ...
|
|
Schneider inverter ATV32 acceleration and deceleration operation method
1. Use the operation method of clicking the button:
In addition to the direction of travel, 2 logic inputs are required to add a speed given, e.g. LI5 is assigned the acceleration function, and LI6 is assigned the deceleration function. Then pressing LI5 will make the speed given increase, and pressing LI6 will make the speed given speed decrease ...
|
|
Rebecca · Lowell · Edwards Schneider Electric's first Global Head of Communications
GENEVA – Rebecca Lowell Edwards, who has been with the International Olympic Committee for the past 18 months·· has joined Schneider Electric as the company's first global communications chief.
In the new work that starts today, love ...
|
|
The ultimate short-circuit breaking capacity of Schneider circuit breakers
The limit short-circuit breaking ability (ICU) refers to the short-circuit current that can be turned on and broken under certain experimental parameters (voltage, short-circuit current, power factor) and through a certain experimental procedure, and after this on-off, it will no longer continue to carry its rated current. It's experiments ...
|
|
The 7 peripherals of the inverter governor - Schneider
1. Air circuit breaker is an active electrical appliance that can not only touch and disconnect the circuit normally, but also operate under abnormal conditions such as overcurrent, reverse current, short circuit and loss (under)voltage. Its primary role is to maintain the electrical equipment in the AC and DC circuits, and it can also operate the circuits infrequently. ...
|
|
Schneider ATS48 soft starter issue
1. What type of ATS48 power supply is?
The control power supply of ATS48 selects communication input, and supplies power to the controller, input and output ports through internal power processing;
The control power supply of Q series products is 220V-415V;
Handling of the Y-Series ...
|
|
Is there a restriction on the installation direction when Schneider installs the inverter?
It should be basically stored in the plate, the problem is that the plate with a fully enclosed structure is large in size, takes up a lot of space, and the cost is higher. This can be done by:
(1) The planning of the disc should be based on the heat dissipation required by the actual device;
(2) Profit ...
|
|
Schneider pushbutton switch type
(1) Protective button: a kind of button with a protective shell that can prevent the internal button parts from being mechanically damaged or people touching the live part, and its code is H.
(2) Dynamic break button: Under normal conditions, the switch contact is a kind of button that is turned on.
(3) Dynamic button: Under normal conditions, the ...
|
|
Schneider TRSS telemetry system solution
Schneider Electric provides safe, reliable, end-to-end telemetry solutions to help you meet the challenges of long-distance operations. With an outstanding reputation in the fields of appearance, manipulation and data collection, wireless communications, IT, and other industries and common sense, Schneider Electric telemetry system solutions can help ...
|
|
Schneider inverter simple question
1. How to complete the control of ATV38 and ATV58 through the operation panel?
First, in the control menu, set "LCC" to "YES" (panel operation); Enter the "LFR" parameter in the adjustment menu, press the up and down keys to adjust the given value, and complete the control of the inverter.
...
|
|
Maintenance and overhaul of frequency converters and soft starters
The protection and viewing of inverters and soft starters is a useful means to prevent occasional equipment problems. In order to be useful for protection and inspection, inspection orders should be created to record and save the inherent characteristics of the equipment and the stability of the constituent parts, so as to prevent problems and problems that occur.
|
|
Schneider inverter fault repair
Inverter communication failure
· Fault code: SLF
Fault title: Inverter communication problem.
Cause of the failure: Communication abort on the inverter communication bus.
The way to deal with the fault: check whether the communication connection is normal: check the communication timeout setting: check the ...
|
|
Fault check steps for frequency converters - Schneider frequency converters
1. Check whether the appearance of the inverter is in good condition, including whether the indicator light is running normally, whether the task control function of the operation panel is complete, and carefully observe the appearance of the inverter in the operating state, and do the corresponding recording work; When repairing the inverter, check whether the voltage value and current value exceed the allowable ...
|
|
Schneider inverter enters the parameter setting method
1. The first step is to check whether the inverter is connected to the line, and whether the wiring of the control line and the power circuit is correct
2. Next, turn on the power of the inverter, enter the motor parameters, and perform motor identification
3. Next, set the function parameters to launch the ...
|
|
Schneider ATV630 VFD series advantages
Depending on the customer's requirements, wall-mounted drives, built-in cabinets and floor-mounted free-standing solutions in protection classes IP 21, IP 23, IP 54 and IP 55 are available.
Thanks to the built-in pump monitoring function, the device reacts immediately when pump efficiency drops, resulting in ...
|
|
The operation essentials of Schneider disconnectors
Schneider Barrier Features: First of all, Schneider Barrier Switch can be used to block the power supply, it is able to disconnect the live equipment from the high-voltage maintenance equipment, and it can also see a significant disconnection point on it. Secondly, the Schneider barrier switch can be used with the circuit breaker to change the operation of the system.
|
|
Introduction to the core knowledge and application of instrumentation - Schneider
Although the "measurement and control skills and instruments" category of majors touch the fields of national defense, aerospace, aviation, sailing, railway, machinery, light industry, chemical industry, electronics, electric power, telecommunications, metallurgy, petroleum, mining, geology, surveying and other industrial, agricultural and scientific research categories, the Ministry of Education has a special understanding of "measurement and control skills and instruments".
|
|
Schneider Instrumentation Classification Standard
The classification specifications for the appearance of the instrument are as follows:
The appearance of the instrument is a comprehensive product of a variety of science and technology, with a wide variety of varieties, wide application, and constantly updated, and a variety of classification methods. According to the purpose and use of the use of the main measuring instrument, car appearance, tractor appearance, marine ...
|
|