A brief description of the K120S series plc

Create Date: 2024-8-30 12:03:23|Source: LS/Power Generation

K120S series PLC product is a unit PLC product introduced to the market by LS in 2004, which has laid a solid foundation in the low-end small machinery supporting industry with its high-performance price ratio. Relying on some special functions of the product, it has also won some industry praise.

                                 A brief description of the K120S series plc

1. Fundamental structure

Economical: 10/14/20/30 point master unit, program capacity 2K, expandable up to 70 points (expandable with 2 expansion modules)

Standard: 20/30/40/60 point master unit, program capacity 10K, expandable up to 120 points (expandable with 3 expansion modules)

Advanced type: The output is basically the same as the standard type, the output is a transistor/relay hybrid output, and the high-speed output of the first 4-point transistor can be connected to a 2-axis servo controller for simple azimuth control function.

2. CPU, fast operation speed 0.1μs/step, no floating point operation, built-in 3-channel communication function, 8-loop PID control, 4-channel 100KHZ high-speed counting function, 2-channel 100KPPS high-speed pulse output.

3. There is no need for battery backup program, the user program is saved in EEPROM, and the data is saved through the supercapacitor (2000 hours at room temperature).

4. HSC function

Single-phase: 100KHZ 2 channels, 20KHZ 2 channels A total of 4 channels for high-speed counting

Duplex: 50KHZ 1 channel, 10KHZ 1 channel A total of 2 channels high speed counting

It has functions such as cycle counting, comparison output, PRM, latching, and presetting.

5. Orientation control function (DRT type products)

2-axis 100KPPS high-speed pulse output function, no differential compensation function, with origin return, inch operation, speed operation, PWM pulse width modulation output, 20 steps of data can be controlled sequentially.

6. Abundant communication function

The 3-channel communication function does not need to be connected to the expansion communication module, and the main unit has a built-in LOADER programming port/RS232C/RS485 These three communication channels, together with the MODBUS function can be used to connect the long-distance station to establish a bus network. The extension module can be used as a slave device for PROFIBUS/DEVICENET.

7. The main unit has a built-in 8-loop unidirectional PID control function, and the self-tuning operation of PID parameters and the realization of PID control can be carried out through the program.

8. an expansion module

A variety of switch/analog expansion modules are available, 4-channel analog potentiometers, 4-channel RTD input modules.
More on that
The essence and use of LS power PLC module The essence and use of LS power PLC module

1. What is PLC? PLC control system, Programmable Logic Controller, programmable logic controller, a digital operation of electronic devices specially designed for industrial production planning, it uses a class of programmable memory, used in its internal storage program, the execution of logic...

Selection of AC contactors in the field of building electrical - LS power production Selection of AC contactors in the field of building electrical - LS power production

1. The series and parallel connection application of contactors Many electrical equipment are single-phase loads, so several poles of multi-pole contactors can be used in parallel. Such as resistance furnaces, welding transformers, etc. When using several poles in parallel, a smaller capacity contactor can be used. However, it must be noted that after parallel ...

Inverter circuit board repair and drawing-free maintenance method - LS power generation Inverter circuit board repair and drawing-free maintenance method - LS power generation

1. Be "confident" It is necessary to fully understand the principles of some typical circuits and be familiar with them. Guangzhou Kewo Training Center believes that drawings are dead, and the thoughts in the head are alive, able to make analogies, able to reason, and able to touch analogies. For example, switching power supply is always inseparable from ...

Inverter external potentiometer connection method - LS power generation Inverter external potentiometer connection method - LS power generation

The two wires are connected to the resistor, and the other wire is connected to the adjustment terminal. The red thread is attached to the blackhead and inserted in a small hole. Connect both ends of the IR potentiometer to +10V and ACM, and slide the termination to the voltage input terminal AVI. ...

The wiring distance between the motor and the inverter The wiring distance between the motor and the inverter

Burn two new motors in a row! The output current and voltage of the inverter are balanced, the input voltage is balanced, the current is unstable, and the fluctuation is 20%-50%, the inverter is burned off by a short circuit between 35Hz turns, the grid voltage is very stable, 720V, the interval between the motor and the inverter is 120m, and the input and output terminals of the inverter are powered ...

Introduction to the design of inverter control cabinet - LS power production Introduction to the design of inverter control cabinet - LS power production

The inverter should be installed inside the control cabinet, and the following problems should be paid attention to when planning the control cabinet: 1) Heat dissipation issues: The heating of the inverter is caused by internal losses. In the inverter, the main circuit is the main circuit for the loss of each part, accounting for about 98%, and the control circuit accounts for 2%. ...

Precautions for inverter installation tips - LS power generation Precautions for inverter installation tips - LS power generation

When the line power supply exceeds the driver's kV-A rating by 10 times, add a line reactor. A 3% impedance line reactor should be used to reduce power line transients caused by capacitor switching, line notching, DC bus overvoltage tripping, and inverter overcurrent and overvoltage conditions. Line...

The internal accessory component of the circuit breaker - the power production circuit breaker The internal accessory component of the circuit breaker - the power production circuit breaker

1. Auxiliary contact: the contact mechanically linked with the main circuit of the circuit breaker and the closing mechanism is mainly used for the display of the circuit breaker and the closing status, and is connected to the control circuit of the circuit breaker through the opening and closing of the circuit breaker to control or interlock its related electrical appliances. For example, output to signal lights, relays, etc.

Inverter fault handling - LS power generation Inverter fault handling - LS power generation

1. The working temperature of the inverter is high 1. Check whether the ambient temperature of the inverter is too high; 2. Check whether the cooling fan inside the device is working normally; 3. Check whether the ventilation pores and mask grilles are blocked; 4. Check if the load is too heavy. ...

Frequency converters are used in special motors? - LS inverter Frequency converters are used in special motors? - LS inverter

In general, the cage rotor motor will be planned according to the frequency conversion, and at the same time the inverter (Variable-frequency Drive, VFD) drag, in different load characteristics, it is necessary to select VFDs with different functions, so now we ask a question. Can VFD be used with ...

The difference between voltage type and current type inverter - LS generates electricity The difference between voltage type and current type inverter - LS generates electricity

The differences between voltage type and current type inverter are mainly manifested in: (1) the load of the buffer inverter of reactive power is an asynchronous motor, which is an inductive load, and in addition to transmitting active power between the intermediate DC link and the motor, there is also the exchange of reactive power. Because power electronic switches ...

LS produces common sense of electroplastic case circuit breaker LS produces common sense of electroplastic case circuit breaker

Now in the process of using molded case circuit breakers, it is necessary to understand the rated current of molded case circuit breakers, and the rated current of molded case circuit breakers generally has more than a dozen, mainly 16A, 25 A, 30A, and the height may reach 630A. L ...

LS produces common sense of electroplastic case circuit breaker LS produces common sense of electroplastic case circuit breaker

(1) Tripping LS electric molded case circuit breaker basically involves the tripping unit in the process of practical application, and the tripping is generally a tripping method of thermomagnetic tripping or electronic tripping. In the process of practical application, if it is a ...

Whether the C-type circuit breaker is suitable for the motor circuit - power generation Whether the C-type circuit breaker is suitable for the motor circuit - power generation

Type C micro-break is used for general circuits, such as lighting circuits; D-type circuit breakers are used in power circuits such as electric motors, so can C-type micro-breakers be used in motor circuits? Differences between C-type and D-type discontinuity: C-type micro-disconnect: with ...

Several basic functions of the inverter - LS generates electricity Several basic functions of the inverter - LS generates electricity

The inverter mainly has the following functions: 1. Soft up The direct launch of the inverter motor will have a severe impact on the power grid, and it will also have too high requirements for the capacity of the power grid, which is extremely unfavorable to the service life of equipment and power grid circuits.

Analysis of the selection of major ventilator inverters - LS power generation Analysis of the selection of major ventilator inverters - LS power generation

Now enterprises need to use a lot of ventilator inverters, the larger the scale of the enterprise, the more production workshops, the more ventilator inverters will be used. However, no matter how large the enterprise, there is a primary ventilator inverter, the selection of this kind of inverter is very important, because if there is no ...

Introduction to the working principle of LS electric molded case circuit breaker Introduction to the working principle of LS electric molded case circuit breaker

Molded case circuit breakers are also known as equipment circuit breakers, all parts are sealed in plastic housings, auxiliary contacts, undervoltage trippers and shunt trippers are modular. Because of the very compact structure, the molded case circuit breaker is basically impossible to maintain. It is mostly manually operated, and the large capacity ...

Variable frequency regenerative braking method - LS generates electricity Variable frequency regenerative braking method - LS generates electricity

1. Energy consumption type This method is to connect a braking resistor in parallel in the DC circuit of the inverter, and control the on/off of a power tube by detecting the DC bus voltage. When the DC bus voltage rises to about 700V, the power tube is turned on, and the regenerative energy is passed into the resistor.

Reasonable selection of LS inverter Reasonable selection of LS inverter

The selection of the inverter should be considered according to the type of controlled object, speed regulation scale, static speed accuracy, starting torque, etc., so that it is easy to use and economical together with the satisfaction of process and production requirements. 1. Inverter and the motor to be operated (1) The number of poles of the motor. General motor ...

The protection measures of the power generator inverter for the motor The protection measures of the power generator inverter for the motor

The protection of the motor by the power converter mainly includes the following aspects: overvoltage protection, undervoltage protection, overcurrent protection, phase loss protection, inverter protection, overload protection, grounding protection, short circuit protection, overfrequency protection and stall protection. ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top