1. The working temperature of the inverter is high
1. Check whether the ambient temperature of the inverter is too high;
2. Check whether the cooling fan inside the device is working normally;
3. Check whether the ventilation pores and mask grilles are blocked;
4. Check if the load is too heavy.
Second, there is no jumping room, but the motor does not work
1. Check whether the indicator light is on and check whether the input power supply is normal;
2. Check whether the control power supply is normal;
3. Check the terminal connection status;
4. Check the type of inverter fault indicator, check and remove the cause of the fault before resetting;
5. Check if the panel control is working, turn on the RUN button to work, and check whether to set the panel working frequency;
6. If it is set to external control, check the status of the external command input terminal and check whether the external work instruction is entered;
7. Check the frequency setting status;
8. Check whether the load applied to the motor is too large or the motor is hindered.
3. The motor rotates in the opposite direction
1. Convert the phase sequence of the output terminals u, v, and w;
2. Convert the forward and reverse signal input of the external working signal;
Fourth, the motor rotates, but the speed does not change
1. Check whether the load is too heavy;
2. The soft stall function has an effect, which can be closed;
3. Check the maximum frequency FH and the upper frequency UL;
4. Check whether the frequency setting signal of the inverter is low;
5. Check the setting characteristics of the frequency setting signal;
6. Check whether the torque increase is too large at low speed and whether the stall prevention alarm is effective
7. Check to see if the signal source has changed.
Fifth, the motor acceleration and deceleration are not stable
Check whether the acceleration time and deceleration time settings are too short.
Sixth, the motor current is large
1. Check whether the motor load is too heavy;
2. Check whether the torque increase is too large at low speed.
|
More on that
|
Recommended models for power production contactors
GMC-6 Contactor GMC-6 Rated voltage: 110V/22OV/380V;
GMC-9 Contactor GMC-9 Rated voltage: 110V/22OV/380V;
GMC-12 Contactor GMC-12 Rated voltage: 110V/22OV/380V;
GMC-18 Contactor GMC-18 Rated voltage 110V/ ...
|
|
The vector control mode of low-voltage general-purpose inverter - LS power generation
The method of vector control frequency conversion speed regulation is to change the stator current Ia, Ib, Ic of the asynchronous motor in the three-phase coordinate system, after the three-phase - two-phase change, equivalent to the communication current Ia1Ib1 under the two-phase static coordinate system, and then after the directional rotation according to the rotor magnetic field, it is equivalent to synchronous rotation sitting.
|
|
Energy-saving method of ventilator inverter - LS power generation
high-power
Although some inverters are fan type inverters, but it is a low-power fan inverter, such an inverter does not have the effect of energy saving, and it is necessary to achieve energy saving must be a high-power inverter, in addition to the high-power fan inverter, it is necessary to meet its ...
|
|
The difference between inverter and power saver - LS produces electricity
First, the frequency conversion skill is only one of the many power-saving skills, including voltage regulation and current limiting, power factor compensation, phased power regulation, frequency conversion, chopping, filtering, energy feedback and other skills, even if the power saver using the principle of frequency conversion is concerned, the frequency converter is only power-saving.
|
|
LS Electric has been selected as one of the "Top 100 Global Innovators" for 10 consecutive years.
In Clarivate's recent statement, LS Electric was named one of the top 100 innovators in the world. The trophy handover ceremony was held in Anyang, LS Electric R&D Park, with Kim Yeong-geun, Chief Technical Officer of LS Electric, and Ahn Seong-sik, CEO of Clarivate Korea, acting as representatives of both parties.
|
|
Why can't the inverter be equipped with a leakage protector?
When using an inverter, a leakage maintainer must not be used. This is a major criterion for the use of frequency converters.
Some users choose the corresponding leakage maintainer for the inverter when using the inverter. *The result is: the inverter moves together ...
|
|
LS power production PLC installation and wiring skills
The PLC should be kept away from strong disturbance sources such as electric welding machines, high-power silicon rectifiers and large-scale power equipment, and should not be installed in the same switch cabinet as high-voltage electrical appliances.
Power line, control line and PLC power line and I/O line should be separated from the wiring, barrier transformer and PLC and I/O should be selected ...
|
|
Advantages of universal inverter - LS produces electricity
Universal inverters are characterized by their versatility. With the development of inverter technology and the continuous expansion of market demand, general-purpose inverters are also developing in two directions: low-cost simple general-purpose LS inverters and high-performance and multi-functional general-purpose inverters. They have the following characteristics:
...
|
|
Precautions for inverter installation and wiring - LS power generation
The inverter is an electric power control equipment that uses frequency conversion skills and microelectronic skills to control the AC motor by changing the power supply frequency of the motor operation. It is used in a wide range of fields, including conveyors, feeders, mixers, grinders, pulverizers, paper cutters, calenders in various industries...
|
|
Precautions for powering on the inverter after the LS power production holiday
1. During the holiday, low temperature can easily cause the equipment to be damp, check whether the electrical equipment is dry, whether there is moisture and condensation;
2. Check whether the grounding wire is loose and whether the cable is damaged by rodents and insects;
3. Sort out the dust and oil stains, and inverter ...
|
|
Dealing with intermittent shutdown fault measures - power generation
Because the touch of the network adapter is not good, perhaps due to disturbance and other problems, the DP network that has been used for a long time may show a "transient disconnection" situation, that is, it will be disconnected by an occasional moment, and it will soon recover normally. If OB86 is not downloaded, the CPU will stop during a transient outage. Now all over the option to download a ...
|
|
Inverter maintenance fault handling method - LS power generation
1. Not manifested. This situation is more common, generally in the normal condition of the external three-phase power supply, it is the switching power supply of the inverter burned, and the 24 volt power supply on the output board of the inverter terminal can be measured.
|
|
LS GTH, GTK series thermal relay models
Thermal Overload Relay GTH-22
GTH series: GTH-22, GTH-40, GTH-85, GTH-100, GTH-150, GTH-220,
GTH-400、GTH-600、GTH-12M、GTH-12MH、GTH-12M、GTH-MH
GTH series: GTH-22, GTH-40, GTH-85 ...
|
|
The torque of the inverter is directly used as the controlled quantity mode - LS generates electricity
VVVF frequency conversion, vector control frequency conversion, and direct torque control frequency conversion are all one of the AC-DC-AC frequency conversion. Its common disadvantages are low input power factor, large harmonic current, large demand for energy storage capacitors in DC circuits, and renewable energy can not be reflected back to the grid, that is, it cannot carry out four-quadrant operation.
|
|
The internal accessories component of the power production circuit breaker
1. Auxiliary contact: the contact mechanically linked with the main circuit of the circuit breaker and the closing mechanism is mainly used for the display of the circuit breaker and the closing status, and is connected to the control circuit of the circuit breaker through the opening and closing of the circuit breaker to control or interlock its related electrical appliances. For example, output to signal lights, relays, etc.
|
|
Fault solution for three-phase asynchronous motor - LS power generation
1. The motor cannot roll after being energized, but there is no abnormal noise, no peculiar smell and smoke.
1. Cause of the problem: (1) The power supply is not connected (at least two phases are not connected); (2) Fuse blowing (at least two-phase blowing); (3) The overcurrent relay is adjusted too small; (4) The wiring of the control equipment is faulty.
2. Question ...
|
|
The inverter generates electricity through the principle of intermediate DC bus power supply - LS
Most of the inverter manufacturers produce traditional inverters, and their control systems and other power supplies are directly provided by single-phase or three-phase power grids. However, due to the increasing use of VFDs and servo motor amplifiers, a new power supply may emerge: powered by the central DC bus of the VFD. This electric ...
|
|
Inverter switching power supply circuit vein - LS power generation
1. Vibration circuit: the drainage-source and R4 of the main winding N1 and Q1 of the switching transformer are the channels for the working current of the power supply; R1 provides the starting current; The self-powered windings N2, D1, and C1 constitute the power supply voltage of the vibrating chip. The normal operation of these three links is the prerequisite for the power supply to vibrate.
|
|
LS inverter series and its features
LS inverter, the full name of LS communication frequency conversion governor, after supplying a variety of equipment, converts direct current into communication electricity, and changes the voltage and frequency of ordinary power supply input to control the speed of the motor, to meet different industrial needs, and then complete the energy saving and environmental protection of the automation system. ...
|
|
Cycloidal reducer transmission system testing - LS power production
With the support of data processing, signal analysis and computer skills, the transmission system uses dynamic error detection equipment, starting from the measurement of time domain error information, and the internal dynamic test of the transmission system should include the following aspects.
...
|
|