Characteristics of single-phase current converter - LS power generation

Create Date: 2024-8-30 12:03:23|Source: LS/Power Generation

Single-phase current transmitter is a kind of power test substation developed for the power measurement of single-phase AC in motor test on the basis of motor test and test technology research, in accordance with IEC and relevant national specifications for motor test. The advanced filtering technology and reasonable software algorithm are used to deal with the problems of low measurement accuracy and unstable measurement data of general appearance. The single-phase current power transmitter has low power consumption, high precision, light weight, and selects personalized planning, digitizes the front-end of measurement, the output signal is digital, and the serial optical fiber bus method is used for transmission, and is centrally managed by the distributed measurement and control master station, which has excellent voltage blocking ability and electromagnetic compatibility, and strong anti-interference. It is suitable for front-end power acquisition of distributed measurement and control test system.

                              Characteristics of single-phase current converter - LS power generation

Single-phase current transducers are characterized by:

1. High accuracy (typical: 0.2% zui is good and 0.05%);

2. The whole range scale has a very high linearity;

3. High degree of integration, simple structure, excellent temperature characteristics and long-term operation stability, so that the transmitter is exempt from timing calibration.

The single-phase current transmitter converts the measured signal into a voltage, which is directly converted into a voltage that has an excellent linear relationship with the measured signal and is completely blocked by the HCNR200/201 linear optocoupler, and then passes through the constant voltage (flow) to the output. It has the advantages of simple principle, refined line planning, high reliability and convenient equipment.

The single-phase current transmitter can directly convert the AC current in the main circuit under test into a constant current loop specification signal of DC 4-20mA (converted into DC 1-5V through 250Ω resistance or DC 2-10V through 500Ω resistance) output in linear shares, and successively transmitted to the receiving equipment (computer or display appearance).

The primary and secondary sides of the single-phase current transmitter are highly insulated, and there are two-wire and three-wire output wiring methods. The three-wire transmitter has a positive end, a negative end and a signal output end of +24V auxiliary operation power supply;

The single-phase current transmitter has the characteristics of high precision, small size, low power consumption, wide frequency response, and anti-interference. The two-wire port has strong anti-induction lightning ability, and has the advantages of lightning wave and surge protection ability. It is especially suitable for the intelligent monitoring system of load current of generators, motors, intelligent low-voltage distribution cabinets, air conditioners, fans, street lights, etc.

The single-phase current converter has ultra-low power consumption, 0.096W when a single static unit, 0.48W at full scale, and 0.6W with an internal limit of output current.

More on that
LS Electric reached a strategic cooperation with Nandu Power Supply and Changzhou Kunlan LS Electric reached a strategic cooperation with Nandu Power Supply and Changzhou Kunlan

Due to the "new infrastructure" policy, the Chinese government has vigorously promoted the new energy and ESS markets, and according to CNESA, the cumulative electrochemical energy storage scale in China will reach 19.3GW in 2023, which is expected to exceed 20% of the global market. June 3 ...

Quickly locate the fault method of switching power supply - LS power generation Quickly locate the fault method of switching power supply - LS power generation

Due to the short circuit of the load, the failure of the self-oscillation circuit and the loss of control of the protection circuit, the switching power supply will cause the base of the switch tube to be unable to get the switching pulse and intermittent operation, which makes it difficult to locate the shortcomings of SMPS. The difficulty of the repair operation and the improper method will expand the shortcomings, constituting the phenomenon of continuous burning of the switch pipe, etc., ...

The working principle of the LS power production module The working principle of the LS power production module

When the LS power generation module is put into operation, its working process is generally divided into three stages: input sampling, user program fulfillment, and output rewriting. The completion of these three phases is called a scan cycle. During the entire operation, the PLC's CPU repeatedly performs the upper ...

Selection principles and key points of AC contactors for power production Selection principles and key points of AC contactors for power production

1. The coil voltage of the contactor should generally be lower, so that the insulation requirements of the contactor can be reduced, and it is safer to use. However, in order to facilitate and reduce the equipment, it is often selected according to the actual grid voltage. 2. The operating frequency of the motor is not high, such as compressor, water pump, air ...

Precautions for powering on the inverter after the LS power production holiday Precautions for powering on the inverter after the LS power production holiday

1. During the holiday, low temperature can easily cause the equipment to be damp, check whether the electrical equipment is dry, whether there is moisture and condensation; 2. Check whether the grounding wire is loose and whether the cable is damaged by rodents and insects; 3. Sort out the dust and oil stains, and inverter ...

The working principle of LS PLC module The working principle of LS PLC module

When LS PLC is put into operation, its operation process is generally divided into three stages, namely input sampling, user program fulfillment and output rewriting. The completion of these three phases is called a scan cycle. Throughout the operation, the PLC's CPU repeatedly performs the performance at a certain scanning speed on ...

How LS PLC works How LS PLC works

Although many names such as relays, timers and counters are often used in the ladder diagram programs used by LS PLC, LS PLC does not have these hardware physically, but uses memory and program programming to do logic control and editing, and connects to external machines through output components.

LS takes you to understand the inverter in the inverter LS takes you to understand the inverter in the inverter

Contrary to the rectifier, the inverter converts the DC power into the communication power of the required frequency, and the 3-phase communication output can be obtained by turning on and off the 6 switching devices at the confirmed time. Take a voltage-type PWM inverter as an example to show the switching time and voltage waveform. Control circuit ...

Maintenance and maintenance method of electric motor - LS generates electricity Maintenance and maintenance method of electric motor - LS generates electricity

1. Look: The normal operation of the motor has a great relationship with the surrounding environment. Therefore, during the daily inspection, check the water leakage and dripping conditions around the motor (which will cause the low insulation of the motor to form a breakdown and cause burnout), and check whether the peripheral of the motor affects its ventilation and heat dissipation ring.

Grounding of the secondary side of the voltage transformer and the current transformer - power generation Grounding of the secondary side of the voltage transformer and the current transformer - power generation

1. The transformer is grounded twice It refers to the grounding of the S2 terminal of the current transformer or the ground of the n terminal of the voltage transformer. As long as the single point is grounded, because the transformer is blocked between the second and the first, before grounding, the secondary winding has no potential connection with the ground, after grounding, the transformer ...

Meaning and classification of LS Electronic Motor Relay (EMPR). Meaning and classification of LS Electronic Motor Relay (EMPR).

The Electronic Motor Relay (EMPR) is a digital motor maintenance relay with an MCU that has a compact and compact form factor that can be combined directly with a contactor. Through the implementation of real-time data processing, high reliability and high precision can be completed, and it can pass through phase loss, reverse, unbalance, stalled rotor, connection...

Application of servo motor - LS power generation Application of servo motor - LS power generation

Quick to use: There are three cables necessary for the operation of the motor: power cable; Motor power line, motor encoder line. Control line interface X5: Servo enable necessary pin C24V power supply (7,41) Servo enable SR ...

Dealing with the "transient" fault method of DP slave - LS power generation Dealing with the "transient" fault method of DP slave - LS power generation

Due to poor contact of network connectors, or due to disturbance and other problems, DP networks that have been used for a long time may show a "transient disconnection" situation, that is, occasionally disconnected instantaneously, and quickly recover to normal. If OB86 is not downloaded, the CPU will stop during a transient outage. Now all over the option to download a ...

Basic introduction to transistors - LS produces electricity Basic introduction to transistors - LS produces electricity

A transistor is a solid-state semiconductor device with a variety of functions such as detection, rectification, amplification, switching, voltage regulation, and signal modulation. A transistor is a variable current switch that can manipulate the output current based on the input voltage. Unlike general mechanical switches (e.g. Relay, swit...)

Cycloidal reducer transmission system testing - LS power production Cycloidal reducer transmission system testing - LS power production

With the support of data processing, signal analysis and computer skills, the transmission system uses dynamic error detection equipment, starting from the measurement of time domain error information, and the internal dynamic test of the transmission system should include the following aspects. ...

Selection of the color of the conductor of the high and low voltage switchgear - LS power production Selection of the color of the conductor of the high and low voltage switchgear - LS power production

1 AC three-phase circuit a) Yellow for phase A, green for phase B, and red for phase C; b) Light and blue colors for the neutral line or neutral line; C) Yellow and green two-color wires are used for safety grounding wires. 2 AC circuits connected by twinax wires or stranded wires: red, black ...

Recommended models for power production contactors Recommended models for power production contactors

GMC-6 Contactor GMC-6 Rated voltage: 110V/22OV/380V; GMC-9 Contactor GMC-9 Rated voltage: 110V/22OV/380V; GMC-12 Contactor GMC-12 Rated voltage: 110V/22OV/380V; GMC-18 Contactor GMC-18 Rated voltage 110V/ ...

Inverter control motor operation method - LS power generation Inverter control motor operation method - LS power generation

When the main circuit of the inverter is connected to the power line, in order to control the operation of the motor, it is also necessary to connect the relevant terminals to the peripheral control circuit, and set the parameters of the inverter's starting method to the external operation form. The inverter controls the motor to run, and there are two common methods, which are to turn on the ...

Interference phenomenon of LS power inverter Interference phenomenon of LS power inverter

1. As soon as the inverter of the heat exchange station is opened, the pressure transmitter jumps randomly; 2. In the water supply controlled by the inverter, the pressure transformer is used as a signal to collect the pressure, and the pressure transformer is disturbed by the inverter; 3. When the inverter starts the motor, the voltage converter signal is unstable and beats violently; 4. Pressure transformer (4-20 ...

The protection measures of the power generator inverter for the motor The protection measures of the power generator inverter for the motor

The protection of the motor by the power converter mainly includes the following aspects: overvoltage protection, undervoltage protection, overcurrent protection, phase loss protection, inverter protection, overload protection, grounding protection, short circuit protection, overfrequency protection and stall protection. ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top