1. The working temperature of the inverter is high
1. Check whether the ambient temperature of the inverter is too high;
2. Check whether the cooling fan inside the device is working properly;
3. Check whether the ventilation pores and mask grilles are blocked;
4. Check if the load is too heavy.
2. There is no jump room display, but the motor is not working
1. Check whether the indicator light is on and check whether the input power supply is normal;
2. Check whether the control power supply is normal;
3. Check the terminal connection status;
4. Check the type of inverter fault indicator, check and remove the cause of the fault before resetting;
5. Check if the panel is working, turn on the RUN button to work, and check whether to set the panel working frequency;
6. If it is set to external control, check the status of the external command input terminal and check whether the external work instruction is entered;
7. Check the frequency setting status;
8. Check whether the load applied to the motor is too large or the motor is hindered.
3. The motor rotates in the opposite direction
1. Convert the phase sequence of the output terminals u, v, and w;
2. Convert the forward and reverse signal input of the external working signal;
Fourth, the motor rotates, but the speed does not change
1. Check whether the load is too heavy;
2. The soft stall function works and can be closed;
3. Check the maximum frequency FH and the upper frequency UL;
4. Check whether the frequency setting signal of the inverter is low;
5. Check the setting characteristics of the frequency setting signal;
6. Check whether the torque increase is too large at low speed and whether the stall prevention alarm is working
7. Check to see if the signal source has changed.
Fifth, the motor acceleration and deceleration are not stable
Check whether the acceleration time and deceleration time settings are short.
Sixth, the motor current is large
1. Check whether the motor load is too heavy;
2. Check whether the torque increase is too large at low speed.
|
More on that
|
Inverter external potentiometer connection method - LS power generation
The two wires are connected to the resistor, and the other wire is connected to the adjustment terminal.
The red thread is attached to the blackhead and inserted in a small hole.
Connect both ends of the IR potentiometer to +10V and ACM, and slide the termination to the voltage input terminal AVI.
...
|
|
The working principle of LS PLC module
When LS PLC is put into operation, its operation process is generally divided into three stages: input sampling, user program fulfillment and output rewriting. The completion of these three phases is called a scan cycle. During the entire operation, the PLC's CPU repeatedly performs the ...
|
|
LS power production contactor application
LS touchers are divided into AC touchers (voltage AC) and DC touchers (voltage DC), which are used in electricity, power distribution and consumption. Toucher broadly refers to the electrical appliances that use the current flowing through the coil to generate a magnetic field in industrial electricity, so that the contacts are closed, so as to control the load.
...
|
|
Introduction to the matching of LS power inverter loads
1. Square torque load
Fan and pump loads are the most widely used equipment in industrial sites, and frequency converters are used in this type of load. It is a square torque load. In general, inverters with U/f=const control mode can be satisfied with the ...
|
|
The main part of LS power inverter is composed
The inverter circuit is the first part of the inverter
The function of the DC central circuit is to smooth the output of the rectifier circuit to ensure that the inverter circuit and the control power supply can obtain a DC power supply with higher quality. When the rectifier circuit is the voltage flow of the central circuit, the primary component is the electrolysis of Darongtong ...
|
|
How to use the installation wiring of the LS inverter
1. Circuit wiring
(1) The input (R, S, T) and output (U, V, W) of the inverter cannot be connected incorrectly;
(2) Wire diameter selection
(1) The wiring of the power supply and the inverter and the wire diameter selection method of the motor of the same capacity are the same;
(2) The wiring between the inverter and the motor should consider the line electricity.
|
|
The matrix alternating control mode of the inverter - LS power generation
VVVF frequency conversion, vector control frequency conversion, and direct torque control frequency conversion are all one of the AC-DC-AC frequency conversion. One of the disadvantages is that the input power factor is low, the harmonic current is large, the DC circuit needs a large energy storage capacitor, and the regenerative energy cannot be reflected back to the grid, that is, it cannot carry out four-quadrant operation.
|
|
Failure analysis of electromagnetic system of LS power production contactor
(1) The core noise is large: it is normal for the electromagnetic system to produce a slight humming sound during operation, if the sound is too loud or abnormal, it can be judged that the electromagnetic system has a problem, and there are three reasons:
(1) Poor contact between the armature and the core or tilting of the armature. After repeated collisions between the touch of the armature and the core, ...
|
|
Inverter air boost test step - LS power generation
1. Download the control program.
2. Put the inverter in open-loop experimental mode and set the appropriate parameters.
3. Connect the incoming cable of the inverter. The cable on the output side of the inverter is not connected.
4. Push the high-voltage cabinet to the experimental position, close the switch, and ...
|
|
Precautions for powering on the inverter after the LS power production holiday
1. During the holiday, low temperature can easily cause the equipment to be damp, check whether the electrical equipment is dry, whether there is moisture and condensation;
2. Check whether the grounding wire is loose and whether the cable is damaged by rodents and insects;
3. Sort out the dust and oil stains, and inverter ...
|
|
The difference between input reactor and output reactor – LS produces electricity
The rectifier part of the general inverter selects the diode uncontrollable bridge rectifier circuit, and the middle filter part selects the large capacitor as the filter, so the input current of the rectifier is actually the charging current of the capacitor, and the harmonic component is relatively steep and steep.
|
|
Precautions for the maintenance of the inverter of the tensile testing machine - LS generates electricity
In the course of regularly checking the variable-frequency drive (VFD) of the tensile testing machine, we can visually check the operating status directly from the outside.
(1) The ambient temperature is normal, and it is required to be between -10°C and +40 ...
|
|
The basic method and steps of inverter debugging - power inverter
1. No-load energizing test of inverter
1. Ground the grounding terminal of the inverter.
2. Connect the power input terminal of the inverter to the power supply through the leakage maintenance switch.
3. Check whether the factory display window of the inverter is normal, if it is incorrect, it should be reset.
|
|
A common fatal form of failure of the terminal block - LS power generation
1. Poor touch
The metal conductor inside the terminal block is the core part of the terminal, which transmits the voltage, current or signal from the external wire or cable to the touch piece corresponding to the connector it matches. Therefore, it is necessary for the touch parts to have excellent structure, stable and reliable touch firmness.
|
|
Introduction of LS inverter IGXA series
LS inverter, the full name of LS AC inverter governor, converts direct current into alternating current by providing a variety of use configurations, and controls the speed of the motor by changing the voltage and frequency of the general power input to meet different industrial needs, so as to complete the energy saving and environmental protection of the automation system. ...
|
|
Principle of electrical equipment maintenance - LS power generation
1. Speak before you start
When it comes to faulty electrical equipment, you should not rush into action, but ask about the passage and phenomenon of the fault.
For unfamiliar equipment, you should also understand the circuit principle and structural characteristics, and follow the corresponding rules. Before dismantling, it is necessary to fully understand each ...
|
|
LS produces common sense of electroplastic case circuit breaker
Now in the process of using molded case circuit breakers, it is necessary to understand the rated current of molded case circuit breakers, and the rated current of molded case circuit breakers generally has more than a dozen, mainly 16A, 25 A, 30A, and the height may reach 630A.
L ...
|
|
The internal accessories component of the power production circuit breaker
1. Auxiliary contact: the contact mechanically linked with the main circuit of the circuit breaker and the closing mechanism is mainly used for the display of the circuit breaker and the closing status, and is connected to the control circuit of the circuit breaker through the opening and closing of the circuit breaker to control or interlock its related electrical appliances. For example, output to signal lights, relays, etc.
|
|
The reason for the overload trip of the inverter - LS generates electricity
1. The load is too heavy, the load carried by the motor is too heavy, or in other words, the resistance torque of the production machinery exceeds the additional torque of the motor.
2. Use improper overload, for example, increase the operating frequency of the inverter to the extra frequency of the motor, and the motor is in the extra frequency.
|
|
What are the determinants of the performance of LS inverters?
The quality of the control circuit determines the function of the LS inverter.
The function of the DC central circuit is to smooth the output of the rectifier circuit to ensure that the inverter circuit and the control power supply can obtain a high-quality DC power supply. When the whole ...
|
|