Precautions for the installation of low-voltage electrical appliances - Schneider

Create Date: 2024-8-30 12:03:23|Source: Schneider/Schneider

1. Low-voltage electrical appliances should be equipped in a place without violent vibration, and should have an appropriate height from the ground. It is necessary to connect the power cord such as the knife switch and the load switch to the fixed contact, and it is forbidden to hang the power cord on the knife switch.

                              Precautions for the installation of low-voltage electrical appliances - Schneider

2. Low-voltage electrical appliances should be vertically equipped. Especially for oil-immersed decompression starters. In order to avoid the insulating oil from spilling out of the oil tank, the inclination should not exceed 5 degrees; Bolts should be used to fix the support, not welding; The orientation of the equipment should be easy to operate, and the handle should be kept at a certain distance from the surrounding buildings so that it is not easy to be damaged.

3. The metal shell or metal bracket of the low-voltage electrical appliance must be grounded (or zeroed), and the exposed part of the electrical appliance should be covered with a protective cover, and the opening direction of the double knife switch should have equipment to avoid self-closing.

4. In the factory with flammable and explosive gases or dust, the electrical appliances should be sealed outdoors, and there are rainproof methods, and it is necessary to use explosion-proof electrical appliances for places with explosion risks.

5. The single-pole switch must be connected to the phase line. Low-voltage appliances for floor-standing equipment. The bottom of the equipment should be 100mm higher than the ground, and the title of the equipment and the circuit number or road type should be indicated on the panel of the equipment and low-voltage electrical appliances.

6. The protective oil layer on each touch surface should be removed before use, and the operation should be operated several times before the operation to check the action status. The static contact of the low-voltage electrical appliance should be connected to the power supply, and the moving contact should be connected to the load.

7. When using, the surface of the electrical contact should be kept clean. Smooth, excellent touch, the contact should have a satisfactory pressure, the action of each phase contact should be common, and the arc extinguishing equipment should remain intact.

More on that
How can industry be high-quality and sustainable? - Schneider How can industry be high-quality and sustainable? - Schneider

Sanya, China, October 21, 2021 – In the context of the ever-changing global development situation and the increasingly urgent response to carbon neutrality, Ruan is moving towards carbon neutrality together with cost reduction and efficiency increase, which has become the focus of attention of many industrial enterprises. As a global digital transformation specialist in power management and automation...

The 7 peripherals of the inverter governor - Schneider The 7 peripherals of the inverter governor - Schneider

1. Air circuit breaker is an active electrical appliance that can not only touch and disconnect the circuit normally, but also operate under abnormal conditions such as overcurrent, reverse current, short circuit and loss (under)voltage. Its primary role is to maintain the electrical equipment in the AC and DC circuits, and it can also operate the circuits infrequently. ...

Key points of operation of Schneider disconnectors Key points of operation of Schneider disconnectors

Features of Schneider Barrier Switch: First of all, Schneider Barrier Switch can be used to block the power supply, it can disconnect the live equipment from the high-voltage maintenance equipment, and can also see the obvious disconnection point on it. Secondly, Schneider barrier switches can cooperate with circuit breakers to change the operation of the system.

Circuit breaker breaking capacity selection - Schneider Circuit breaker breaking capacity selection - Schneider

How to choose the circuit breaker break? Rated voltage and current are the key For professional electrical operators, the question of how to choose the circuit breaker can be said to be easy and effortless, but it is a bit difficult for novices. Circuit breaker breaking can ...

The selection method of inverter power - Schneider The selection method of inverter power - Schneider

The system power is equal to the product of the inverter power and the motor power, as long as both are operating at a higher power, the system power is higher. From the power point of view, when selecting the power of the inverter, the following points should be noted: ...

The difference between the highest frequency and the basic frequency of the inverter - Schneider The difference between the highest frequency and the basic frequency of the inverter - Schneider

1. There are two ways to say the fundamental frequency: (1) The frequency corresponding to the maximum output voltage of the inverter is called the fundamental frequency; (2) When the output voltage of the inverter is equal to the additional voltage, the minimum output frequency is called the fundamental frequency. The fundamental frequency is expressed in fBA. ...

Precautions for false load connection in Schneider inverter debugging Precautions for false load connection in Schneider inverter debugging

There are many novices who are not familiar with the fake load when repairing the inverter, and the repair of the inverter saves many of their modules with the false load, because the novice repairer generally does not know how to do this, and now the light is on to make it clear that the module is going to be broken. A false load is a resistor with a few hundred ohms ( ...

Schneider PLC control cabinet installation wiring method Schneider PLC control cabinet installation wiring method

(1) When placing signal cables with different properties into the same conduit, they must be isolated (2) Try to avoid accommodating multiple power cords in the same conduit. When it is necessary to set up, a partition should be placed inside the conduit and the partition should be grounded. ...

Common maintenance problems for Schneider drives Common maintenance problems for Schneider drives

1. Why is the inverter used for fan and pump loads to save energy? According to the basic law of fluid mechanics, it can be seen that the fan pump load is a typical square rotation load, and its primary feature is that the speed n has the following relationship with the torque T and the load power P: T∝n2, P∝n3. ...

Schneider inverter maintenance power settings, waveform test problems Schneider inverter maintenance power settings, waveform test problems

1. After the inverter is repaired, the power number needs to be modified, don't forget it Generally, an inverter corresponds to a power number (also known as the number of horsepower), for example, a 75 kilowatt inverter is set under heavy load, and 100 kilowatts is set under light load. In this way, the customer will not use it to present ...

Schneider Electric Innovation Summit "The future is digital" Schneider Electric Innovation Summit "The future is digital"

The name of a company's product was mentioned more than anyone could remember, but on the first day of the Schneider Electric North America Innovation Summit in Atlanta on Tuesday, another word appeared even more often ...

The difference between Schneider miniature circuit breaker and leakage switch The difference between Schneider miniature circuit breaker and leakage switch

1. Definition of miniature circuit breaker The electrical occupation is referred to as MCB, which is suitable for communicating 50/60Hz additional voltage 230/400V, additional current to 63A line overload and short circuit maintenance, and can also be used as infrequent operation conversion of the line under normal circumstances. ...

Frequency converter main circuit fault solution - Schneider Frequency converter main circuit fault solution - Schneider

According to the statistical analysis of the frequency and shutdown time of the specific common problems of the inverter, the repair rate of the main power supply circuit accounts for more than 60%; The main operating parameters are set improperly, resulting in about 20% of common problems; 15% of the common problems of manipulating circuit boards; 5% of common problems are caused by incorrect operation and external anomalies ...

Precautions for the selection of Schneider foot switches Precautions for the selection of Schneider foot switches

The foot switch series is XPE, and it should be noted when selecting: 1) Raw materials: metal and plastic, which are used in heavy-duty, high-risk, light-duty, low-risk occasions. 2) Pedal: divided into single pedal and double pedal (type end plus D). 3) With or without maintenance cover ...

Schneider PLC signal light meaning Schneider PLC signal light meaning

Take the Schneider PLC with model number TWDLCAA40DRF as an example: The first PWR: is the meaning of power supply; The second RUN: is the PLC operation indicator; Long dark: The application is not fulfilling; Shine: The controller is in a stay or a mistake in performance; Solid on: The controller is in operation ...

Schneider miniature circuit breaker model and parameter difference Schneider miniature circuit breaker model and parameter difference

Schneider miniature circuit breakers are commonly used in C65, C120, EA9, INT125 and other products. Parameter differences: N -------- breaking ability, N is 6000A, H is 10000A, L is 15kA ...

Schneider ATV71 inverter installation and modulation setting steps Schneider ATV71 inverter installation and modulation setting steps

1. Schneider inverter menu: (1) Simple start: Self-tuning: If the manifestation is "unfinished", then select "supplication self-tuning" until the manifestation is "finished", i.e., the completion of self-tuning; Acceleration moment: a ...

Schneider inverter and PLC connection problems Schneider inverter and PLC connection problems

When the inverter is used to form an automatic control system for control, in many cases, PLC and inverter are used together, and how to correctly connect the PLC and inverter together has become the key to the success of the system. 1.PLC switch ...

How to choose a Schneider circuit breaker? How to choose a Schneider circuit breaker?

First, calculate the value of the current of each branch (1) Purely resistive loads, such as bulbs, electric heaters, etc., are directly divided by the indicated power by voltage, that is, the formula I = power/220v; For example, a 20w bulb, branch current I=20W/220=0.09A electric air ...

Inverter selection principle - Schneider Inverter selection principle - Schneider

1. Select the inverter according to the load characteristics. 2. When selecting the inverter, the actual motor current value should be used as the basis for the selection of the inverter, and the additional power of the motor can only be used as a reference. Secondly, the output content of the inverter should be fully considered.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top