Schneider inverter maintenance power settings, waveform test problems

Create Date: 2024-8-30 12:03:23|Source: Schneider/Schneider

1. After the inverter is repaired, the power number needs to be modified, don't forget it

Generally, an inverter corresponds to a power number (also known as the number of horsepower), for example, a 75 kilowatt inverter is set under heavy load, and 100 kilowatts is set under light load. In this way, customers will not show a mismatch phenomenon when using it.

Some inverters are set at the factory or even forget to set the number of power, which ultimately leads to the incorrect use of the customer's site. In fact, after the repair of each inverter, it is necessary to pay attention to check whether the set parameters meet the needs of customers. This is not negligent.

                           Schneider inverter maintenance power settings, waveform test problems

2. The waveform test must not be less

The waveform test focuses on testing whether the driver board and the inverter composition equipment are good, and the test process is measured under high-voltage DC transmission, and the first safety can not be ignored, and secondly, the test point must be accurate, and it is not possible to form a short circuit and set up damage to important components.

3. Screw tightening inspection can not be ignored

The danger of loosening the screws should not be underestimated. For example, the loosening of the three-phase input and output terminals can lead to the unevenness of the three-phase input and output, and even burn out the terminal row in the state of high current, and even cause load damage due to lack of phase.

Loosening of the grounding screw can lead to poor grounding and increase the touch resistance. It shows the phenomenon of fire ablation.

In summary: these links are the most likely to be negligent, and the consequences of negligence are more serious. Similar problems have already been presented in the ordinary production process, and it is necessary to make a good experience analysis. Don't touch on similar issues again.

More on that
Inverter trip protection circuit – Schneider Inverter trip protection circuit – Schneider

After the maintenance function of the inverter is caused by the operation of the problem, it will trip immediately, and the fault code will be displayed together, and the tripping alarm indication circuit of the peripheral inverter will send out an audible and visual alarm to remind the operator to clean up the problem in time. Inverter hopping ...

Schneider UPS power supply installation precautions Schneider UPS power supply installation precautions

The quality of UPS power supply devices directly affects the long-term operation of the UPS system in the future, especially the large and medium-sized UPS power supplies, so the large and medium-sized UPS power supplies should be standard in the process of planning to the device. Generally speaking, UPS power supply ...

Factors influencing the differential thermal analysis of instrumentation - Schneider Factors influencing the differential thermal analysis of instrumentation - Schneider

The operation of differential thermal analysis is simple, but in practical work, it is often found that the same sample is measured on different instruments, or different measurements are measured on the same instrument, and the results of the differential thermal curve of industrial electrical appliances are different. The high temperature, shape, area, and size of the peaks will all change. ...

Schneider inverter motor control mode Schneider inverter motor control mode

Fundamentals of magnetic flux vector manipulation The control of a three-phase asynchronous motor is much more messy than that of a DC motor because the current, voltage, induced potential, magnetic flux, etc., of the stator and rotor are all alternating. However, the stator winding of the three-phase asynchronous motor is a symmetrical three-phase winding, which exerts a ...

Calculation method of inverter capacity - Schneider Calculation method of inverter capacity - Schneider

1. Accounting of inverter capacity when the load is continuously changed periodically In many cases, the load of the motor changes periodically. Obviously, in this case, picking the capacity of the inverter according to the minimum load will be overloaded, and it will be uneconomical to select according to the maximum load.

Schneider improves plant performance with automated control Schneider improves plant performance with automated control

1. Engineering planning one by oneWith data at their fingertips and intelligent and sensitive functions, engineers can easily plan and test equipment, improve process availability, and easily complete system integration together – ultimately reducing the planning time by up to 25%. ...

Schneider inverter enters the parameter setting method Schneider inverter enters the parameter setting method

1. The first step is to check whether the inverter is connected to the line, and whether the wiring of the control line and the power circuit is correct 2. Next, turn on the power of the inverter, enter the motor parameters, and perform motor identification 3. Next, set the function parameters to launch the ...

Common maintenance problems for Schneider drives Common maintenance problems for Schneider drives

1. Why is the inverter used for fan and pump loads to save energy? According to the basic law of fluid mechanics, it can be seen that the fan pump load is a typical square rotation load, and its primary feature is that the speed n has the following relationship with the torque T and the load power P: T∝n2, P∝n3. ...

Precautions for false load connection in Schneider inverter debugging Precautions for false load connection in Schneider inverter debugging

There are many novices who are not familiar with the fake load when repairing the inverter, and the repair of the inverter saves many of their modules with the false load, because the novice repairer generally does not know how to do this, and now the light is on to make it clear that the module is going to be broken. A false load is a resistor with a few hundred ohms ( ...

Instrumentation anti-interference measures - Schneider Instrumentation anti-interference measures - Schneider

The interference encountered by sensors and instruments in the field operation is varied, and the specific situation is analyzed on a case-by-case basis, and the principle of anti-interference is to adopt different methods for different disturbances. This flexible and mobile strategy is undoubtedly opposed to universality, and the way to deal with it is to choose a modular approach, except for ...

Schneider's method of improving the power factor of UPS power supplies Schneider's method of improving the power factor of UPS power supplies

One. The significance of the progressive power factor. 1. Make full use of the ability of power equipment. Each power supply unit has additional capacity, i.e. depending on the power. The total power output of the power supply equipment S, - part of the active power, the other part is the reactive power, the smaller the ...

Features of Schneider explosion-proof inverter boxes Features of Schneider explosion-proof inverter boxes

1. Aluminum alloy shell or steel plate welding, plastic spraying on the surface; 2. Built-in inverters, circuit breakers, signal lights and other components produced by domestic or Schneider and other companies; ​ 3. It mainly regulates the general three-phase difference by changing its output frequency.

Frequency characteristics of frequency converters – Schneider Frequency characteristics of frequency converters – Schneider

a. Output frequency scale. The output frequency scale that can be controlled by the general inverter is generally 0.1Hz, and the highest frequency is different according to the functional indicators of the inverter, generally 400Hz, and some models are 650Hz. No matter how high the output frequency is, it belongs to the scale of high-frequency inverter. ...

Introduction to Schneider PLC series Introduction to Schneider PLC series

1. LMC058 & LMC078 Modicon Motion Controller Product Information Faster machine planning The motion controller uses the same programming software as the PLC; Custom-made utility blocks for complex use; Dedicated motion function library for programming, debugging, and diagnosis ...

Schneider ATV630 VFD series advantages Schneider ATV630 VFD series advantages

Depending on the customer's requirements, wall-mounted drives, built-in cabinets and floor-mounted free-standing solutions in protection classes IP 21, IP 23, IP 54 and IP 55 are available. Thanks to the built-in pump monitoring function, the device reacts immediately when pump efficiency drops, resulting in ...

Schneider UPS power supply installation steps Schneider UPS power supply installation steps

UPS power supply is widely used in shopping malls, supermarkets, banks and other enterprises and institutions, the primary effect of the power supply is to provide continuous power supply for the unit in the state of power failure, so as to ensure the normal operation of the computer network system and other application systems, and effectively avoid data loss. In the power supply ...

Schneider inverter fault repair Schneider inverter fault repair

Inverter communication failure · Fault code: SLF Fault title: Inverter communication problem. Cause of the failure: Communication abort on the inverter communication bus. The way to deal with the fault: check whether the communication connection is normal: check the communication timeout setting: check the ...

Schneider inverter simple question Schneider inverter simple question

1. How to complete the control of ATV38 and ATV58 through the operation panel? First, in the control menu, set "LCC" to "YES" (panel operation); Enter the "LFR" parameter in the adjustment menu, press the up and down keys to adjust the given value, and complete the control of the inverter. ...

Schneider ATV71 selection and letter meaning Schneider ATV71 selection and letter meaning

The type of Schneider inverter generally reflects the rated voltage, rated power, and load requirements of the inverter (heavy or light load). Here are two examples: Example 1: Schneider Inverter Type: ATV71HD11N ...

How to identify the quality of an inverter – Schneider How to identify the quality of an inverter – Schneider

Nowadays, the function of domestic inverters is becoming more and more mature, with a wide variety and dazzling. Many brands have been tested by the market, but there are also some brands that have been imitated and counterfeited to disrupt the market. One of the major characteristics of domestic brands is that they are both like domestic brands and imported brands. The brand's ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top