Dynamic phase angle tuning of inverter motors – Schneider

Create Date: 2024-8-30 12:03:23|Source: Schneider/Schneider

1. The control cabinet, the main engine, and the brake connection line are correct, and the voltage is correct;

2. Safety circuit, door lock circuit is normal, limit switch, speed change switch and close;

3. The connection cable from the encoder to the PG card must be reliable and accurate;


                              ​ Dynamic phase angle tuning of inverter motors – Schneider

4. Admit that after the brake is opened, the elevator will not slip (able to lift the car or balance the load state);

5. Adjust the parameters of the inverter: A04=1 (acquiesce to 1, which should be the same as the parameter setting of the motherboard);

B11=1 (the speed of the main engine is less than 100, it must be set to 1);

  C02=0;

  C13=1;

  E01=1;

E02=number of poles;

E03=Rated voltage;

E04=rated speed;

E05=rated current;

E09=0 (tacitly Heidenhain 1387) encoder type;

E10=2048;(Other parameters do not need to be changed, keep the factory value)

6. Set A03=4, and then give the control cabinet maintenance signal, the control system will give the inverter direction signal, enable the signal;

If the D1 and D2 lights of the inverter operator are on, and the monitoring U14 parameters are monitored, it is necessary to increase, otherwise the V and W phases of the inverter output are replaced;

If the D1 and D3 lights of the inverter operator are on, and the U14 parameters are monitored, it is necessary to reduce, otherwise replace the V, W phase of the inverter output;

If there is no change in the U14 parameters, check whether the brake is opened, or whether the voltage is not enough to maintain the voltage of the brake after the brake is released;

7. After the tuning is completed, A03=3, the position of the encoder after tuning is in U15, repeat 6 three to four times, if the parameters after tuning are within -10......+10, then set A03 to 0;

8. If the main engine rotates normally and the setting is completed.

More on that
Schneider's method of improving the power factor of UPS power supplies Schneider's method of improving the power factor of UPS power supplies

One. The significance of the progressive power factor. 1. Make full use of the ability of power equipment. Each power supply unit has additional capacity, i.e. depending on the power. The total power output of the power supply equipment S, - part of the active power, the other part is the reactive power, the smaller the ...

Frequency converter main circuit fault solution - Schneider Frequency converter main circuit fault solution - Schneider

According to the statistical analysis of the frequency and shutdown time of the specific common problems of the inverter, the repair rate of the main power supply circuit accounts for more than 60%; The main operating parameters are set improperly, resulting in about 20% of common problems; 15% of the common problems of manipulating circuit boards; 5% of common problems are caused by incorrect operation and external anomalies ...

Knowledge of Schneider Lexium32 servo motors Knowledge of Schneider Lexium32 servo motors

Schneider Lexium32 servo motor new generation servo release enriches Schneider Electric's high-end product line, its outstanding product functions, sensitive openness and user-friendly planning will better meet the high functional and safety requirements of industrial customers. In China's industrial production is increasingly moving towards energy-saving ...

Frequency converters and their control – Schneider Frequency converters and their control – Schneider

AC inverter is the result of the high development of microcomputer and modern power electronics technology. The microcomputer is the center of the inverter, and the power electronics form the main circuit of the inverter. As we all know, the frequency of communication electricity sent from power plants is stable and constant, in our country it is 50 weeks per second ...

Schneider instrumentation maintenance precautions Schneider instrumentation maintenance precautions

1. When installing and adjusting the appearance, the original status should be recorded for rehabilitation. 2. When repairing the appearance of fine instruments, if you accidentally bounce small parts away, you should first determine the direction where you can fly.

Turbine flowmeter selection factor - Schneider Turbine flowmeter selection factor - Schneider

Turbine flowmeter is a kind of speed appearance, it has high precision, good repeatability, no zero drift, high range ratio, simple structure, few moving parts, high pressure resistance, wide measurement scale, small size, light weight, small pressure loss, convenient repair and other advantages, turbine flowmeter has high quality ...

Deterioration site and the principle of higher harmonic generation - Schneider Deterioration site and the principle of higher harmonic generation - Schneider

1. Electrical equipment will produce higher harmonics when it produces abnormality and deterioration, and the abnormality and deterioration of motors, loads, and inverters are used to distinguish the higher harmonics from 2 to 40 times, and the data is changed by FFT, and the analysis is made on the basis of the analysis data of long-term savings.

Schneider PLC control cabinet installation wiring method Schneider PLC control cabinet installation wiring method

(1) When placing signal cables with different properties into the same conduit, they must be isolated (2) Try to avoid accommodating multiple power cords in the same conduit. When it is necessary to set up, a partition should be placed inside the conduit and the partition should be grounded. ...

Schneider EZD series molded case circuit breaker is recommended Schneider EZD series molded case circuit breaker is recommended

Create a high-quality circuit breaker for secondary power distribution EZD molded case circuit breaker is a product series of molded case circuit breakers specially designed for secondary power distribution, especially suitable for secondary power distribution, civil construction market and mechanical and electrical market.

The contents of the daily inspection of Schneider inverters The contents of the daily inspection of Schneider inverters

1) Whether the ambient temperature is normal or not, it is required to be in the range of -10-+40 °C, and it is better to be about 25 °C. whether the humidity meets the requirements, and whether the ventilation and heat dissipation of doors and windows are outstanding; Whether the lower air inlet and upper air outlet of the inverter are dusty or blocked due to excessive dust. ...

Schneider inverter fault repair Schneider inverter fault repair

Inverter communication failure · Fault code: SLF Fault title: Inverter communication problem. Cause of the failure: Communication abort on the inverter communication bus. The way to deal with the fault: check whether the communication connection is normal: check the communication timeout setting: check the ...

Inverter control motor speed method - Schneider Inverter control motor speed method - Schneider

1. Why can the rotation speed of the motor be changed freely? Motor rotation speed unit: r/min number of rotations per minute, can also be expressed as rpm. Example: 2-pole motor 50Hz 3000 [r/min] 4-pole motor 50Hz 1500 [r/min] Conclusion:...

Schneider Multi9 Series C120L Problem Schneider Multi9 Series C120L Problem

1. What are the characteristic curves of Schneider Multi9 series C120L? C/D curves. 2. What is the rated current level of Schneider Multi9 series C120? 63A、80A、100A、125A。 3. What is the weight of Schneider Multi9 series C120? 1P:205 ...

Schneider UPS uninterruptible power supply debugging precautions Schneider UPS uninterruptible power supply debugging precautions

1. Check whether all switches are in the disconnected position; 2. Check whether there are foreign objects in the UPS uninterruptible power supply cabinet and transformer; Check whether the flat cable connection is correct and whether it is loose; 3. Check that the connected plug is ...

The method of controlling the speed of the motor by the inverter - Schneider The method of controlling the speed of the motor by the inverter - Schneider

1. Why can the rotation speed of the motor be changed freely? Motor rotation speed unit: r/min number of rotations per minute, can also be expressed as rpm. Example: 2-pole motor 50Hz 3000 [r/min] 4-pole motor 50Hz 1500 [r/min] Conclusion:...

Schneider's small PLC part model Schneider's small PLC part model

  Schneider has M100/M200 for small programmable controllers, and M340 and M580 for medium and large programmable controllers The compact M100 model is available in TM100C24RN, TM100C32RN, and TM100C40RN. Small M200 ...

The difference between Schneider verification, calibration, and calibration The difference between Schneider verification, calibration, and calibration

What is the difference and contact between the instrument, external work verification, calibration, and calibration? Verification, calibration, and calibration are all static measurement processes that are carried out in cycles. The meanings are: The verification ---- shall be arranged by the legal metrology department or the statutory authorization in accordance with the verification procedures, after ...

Schneider inverter disturbance and treatment method Schneider inverter disturbance and treatment method

A. Methods of Communication: (1) Radiation disturbance (2) Conduction disturbance B. Immunity Methods With regard to nuisance signals transmitted by radiation methods, they are primarily weakened by wiring and shielding the radioactive source and the disturbed lines. About Tong ...

Inverter maintenance mantra method - Schneider Inverter maintenance mantra method - Schneider

Don't worry about the damage of the frequency conversion, disassemble the machine after the discharge; It is indispensable to ask for a diagnosis and clarify the problem at the beginning of the test; Input and output PN junction, three-phase balance and then unshelling; Look at the nameplate before powering on, the wrong voltage will blow up; The bus has no electricity to see that it is safe, and the rectifier filter is wrong ...

Schneider Electric executive support merger software Saas company Schneider Electric executive support merger software Saas company

MergerWare has raised an undisclosed amount of money ahead of its Series A funding round, an executive told TechCircle. The Company provides software solutions to help integrate mergers and acquisitions-related businesses. The funding came from electrical equipment manufacturer Schneider Electric (Schneider ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top