Deterioration site and the principle of higher harmonic generation - Schneider
1. Electrical equipment will produce higher harmonics when it produces abnormality and deterioration, and the abnormality and deterioration of motors, loads, and inverters are used to distinguish the higher harmonics from 2 to 40 times, and the data is changed by FFT, and the analysis is made on the basis of the analysis data of long-term savings.
|
|
Instrumentation mechanical equipment system - Schneider
1. Power system:
The wire and cable products selected in the power system mainly include overhead bare wires, busbars (busbars), power cables (plastic cables, oil-paper power cables (fundamentally replaced by plastic power cables), rubber cables, overhead insulated cables), branch cables (replacing part of the busbars), ...
|
|
Schneider relay model introduction
RM4 Series Control Relay (Three-phase Power Control)
RM4 series voltage steerable relays
RM4 current operated relay
RM4 level control relay
RM17 three-phase power controller
RM35 3-phase power control relay
RM17 Voltage Steerable Relay ...
|
|
Instrumentation anti-interference measures - Schneider
The interference encountered by sensors and instruments in the field operation is varied, and the specific situation is analyzed on a case-by-case basis, and the principle of anti-interference is to adopt different methods for different disturbances. This flexible and mobile strategy is undoubtedly opposed to universality, and the way to deal with it is to choose a modular approach, except for ...
|
|
Precautions for the selection of Schneider molded case circuit breaker
1. Shell current and rated current
The size of the shell current is 100 (rated current 16 25 32 40 63 80 100) 250 (rated current 160 250 400 (rated current 250 400) 630 (rated current 630A.)
...
|
|
Schneider Category VI unshielded RJ45 information module
Product Introduction
compose
1. RJ45 module body, 8 IDC contact pins
2. Crimping module
3. Back cover 7751S (optional)
Operating temperature range
-40°C to +70°C (65°C for non-stop use)
...
|
|
Turbine flowmeter selection factor - Schneider
Turbine flowmeter is a kind of speed appearance, it has high precision, good repeatability, no zero drift, high range ratio, simple structure, few moving parts, high pressure resistance, wide measurement scale, small size, light weight, small pressure loss, convenient repair and other advantages, turbine flowmeter has high quality ...
|
|
Selection and control of the inverter installation - Schneider
Frequency converters are widely used equipment in modern industry. If you want to complete the functions of soft stop, soft start, stepless speed regulation or special requirements for speed rise and fall, you need the more advanced speed control equipment in modern asynchronous motors - frequency converters. The main circuit of the equipment is selected to communicate - DC - communication ...
|
|
Rebecca · Lowell · Edwards Schneider Electric's first Global Head of Communications
GENEVA – Rebecca Lowell Edwards, who has been with the International Olympic Committee for the past 18 months·· has joined Schneider Electric as the company's first global communications chief.
In the new work that starts today, love ...
|
|
Schneider miniature circuit breaker code calling
Schneider miniature circuit breaker code marking method
For example: 1-C65N-C20A/2P+VE+30mA+SD, the meaning of each item is:
1--------- identification number
C65 ------ serial code
N -------- breaking ability, N is 6000A, H is 10000A, L is 15kA
...
|
|
Schneider inverter frequency signal source mode
In order for the inverter to operate normally, it must have two basic conditions, that is, the frequency signal and the operating signal, let's talk about the first condition, which is the frequency signal of the inverter.
Our intention to use the inverter is to change the ...
|
|
Introduction to Schneider inverter fault code and maintenance method
1. If the fault code presented on the Schneider inverter is AnF, it means that the load of the inverter has slipped, that is, the speed of the encoder does not match the initial value. First of all, we need to check whether the parameters of the motor are stable and the size of the load, ...
|
|
Commissioning steps for Schneider drives
1. Type recognition: Recognize whether the type of inverter is common with the type of inverter purchased.
2. Transportation acknowledgement: After opening the package, check whether the inverter is damaged during transportation.
3. Voltage recognition: the power supply voltage on the site should be borne by the inverter.
|
|
Schneider inverter ATV32 acceleration and deceleration operation method
1. Use the operation method of clicking the button:
In addition to the direction of travel, 2 logic inputs are required to add a speed given, e.g. LI5 is assigned the acceleration function, and LI6 is assigned the deceleration function. Then pressing LI5 will make the speed given increase, and pressing LI6 will make the speed given speed decrease ...
|
|
Schneider PLC control cabinet installation wiring method
(1) When placing signal cables with different properties into the same conduit, they must be isolated
(2) Try to avoid accommodating multiple power cords in the same conduit. When it is necessary to set up, a partition should be placed inside the conduit and the partition should be grounded.
...
|
|
Anti-electromagnetic interference method - Schneider
There are three main sources of electromagnetic disturbance to the industrial system: first, space field disturbance, which enters the system through electromagnetic wave radiation; the second is power disturbance, which directly damages the system; The third is the signal disturbance channel, which enters the system through the front and rear channels connected to the host. In order to ensure that the instrumentation ...
|
|
Precautions for motor operation over 60Hz - Schneider
What problems should be paid attention to when the motor works beyond 60Hz?
The following precautions should be taken when operating beyond 60Hz
(1) Machinery and equipment should have sufficient potential to work at this speed (mechanical strength, noise, vibration, etc.).
(2) ...
|
|
Safety PLC is different from ordinary PLC
A safety PLC differs from conventional PLCs in that it needs to be certified for safety by a third-party professional organization and meet stringent international standards for safety and reliability. There is a need for a thorough systematic approach to the planning and testing of safety PLCs. TUV*** in Germany and FM*** in United States ...
|
|
Key points of maintenance of Schneider battery
(1) Insulating pads should be arranged in the maintenance channel of the battery pack.
(2) It is strictly forbidden to use batteries of different manufacturers, different capacities and different models in the same system.
(3) VRLA batteries do not need to be charged for the first time before use, but should be recharged. Replenish the charge ...
|
|
Inverter maintenance inspection steps – Schneider
1. Check whether the appearance of the inverter is in good condition, including whether the indicator light is in normal operation, whether the task control function of the operation panel is complete, and carefully observe the appearance of the inverter in operation conditions, and do the corresponding recording operations; When repairing the inverter, check whether the voltage value and current value exceed the allowable ...
|