1. Set temperature: Press the SET button to set or view the temperature set point. Press the SET button at the beginning of the digital tube character flashing, indicating that the appearance has entered the setting state, press the △ key to increase the set value, press the ▽ key to decrease the set value, press and hold the △ key or ▽ key data will change rapidly, press the SET button again to return to the normal operating condition of the surface temperature setting end.
2. Return control (XMT201-C): Press the SET button for 3 seconds to enter the inner layer parameter setting status. The first presented and flashing parameter is C00, that is, the return difference control parameter should be adjusted steadily, the appearance of the control heating output value to the set value, when the temperature falls to the set value and the difference is reduced, the end of the heating, the output (relay) is not active in the return range, so that the relay action times can be reduced to extend the life of the relay. For example, if the setting value is 80.0°C and the return difference is 0.5, the relay is released when the surface control is heated to 80.0°C, and the relay is engaged again when the temperature drops to 80.0°C-0.5°C=79.5°C. The larger the return difference, the fewer the relay actions, and the excessive return difference will reduce the control accuracy. After adjusting the differential parameters, press the SET button for 3 seconds to return to the normal operating condition.
3. Early Setting (XMT201-E): Press the SET button for 3 seconds to enter the inner layer parameter setting. The first parameter presented and flashed is E00, that is, the early amount of heating stopped, the early amount parameter should be adjusted steadily, in order to reduce the temperature overshoot, the heating output will be cut off early when the surface is controlled. When the temperature drops below the early amount, the heat is started again, and the output (relay) is not operated within the range of the set value and the early amount, so that the number of relay actions can be reduced to extend the life of the relay. For example, if the setting value is 50.0°C and the early amount is 0.5, the relay will be released when the surface control is heated to 49.5.0°C, and the relay will be engaged again when the temperature drops to 50.0°C-0.5°C=49.5°C. The larger the early amount, the fewer the relay actions, and the excessive early amount will reduce the control accuracy. After adjusting the early amount parameters, press the SET button for 3 seconds to return to the normal operation status
4. Time share setting (XMT201-P): Press the SET button for 3 seconds to enter the inner layer parameter setting status. E: is the share band offset, and the E parameter allows the practice control point to be translated. Even if the center of the moment share shifts, the E-value can be positive or negative depending on the heating system. P: is the share band, that is, the share manipulation value, in order to facilitate understanding and also to make the share with a larger representation space, the share band in this table is a unilateral share band, that is, the practical share band is 2 times the P value. Focusing on the practice control point, the output heating share is evenly distributed from 0% to 100% in the P-value range. T: For the heating output cycle cycle, that is, the relay operation cycle cycle, the T value is small and the control effect is good, but the T value is too small The relay will reduce the life due to frequent operation. Generally, the T value is taken for 20-60 seconds. For example, if P is set to 4.0 (the actual band is 8.0), the temperature is set to 60.0 degrees, and E is set to 2.0, then the practice control point is 58.0 degrees, and when the temperature reaches 54.0 degrees, the appearance will enter the share band control state.
5. Intelligent control parameter setting (XMT201-D): Press the SET button for 3 seconds to enter the inner parameter setting status on the outer surface. E: This parameter is the early amount of heating stop when P = 0, when P is not equal to 0, the appearance is intelligent PID operation mode, and when P is not equal to 0, E parameter is meaningless. P: is the share band, that is, the share control value, the surface is centered on the set value, the P value is scattered on both sides of the set point, and the surface is operated in PID mode within the P value range. T: For the heating output cycle cycle, that is, the relay operation cycle cycle, the T value is small and the control effect is good, but the T value is too small The relay will reduce the life due to frequent operation. Generally, the T value is taken for 20-60 seconds. To simplify the operation, the integration time (I) and the differential moment (D) of the appearance are designed as hidden parameters, and their default values: I=180, D=45
6. Correction of errors: Correction of the apparent value can be made when it is admitted that the apparent value is not the correct measured value. Press the SET button for 3 seconds to enter the inner menu on the surface, the first parameter presented and flashed is E00, that is, the early amount, and then press the SET button again to present and flash the parameter that is the error correction parameter, and this parameter can be corrected with the △ or ▽ key. The error correction range is -9.9°C to +9.9°C, and after the correction is completed, press the SET button to exit. The correction value of the appearance is 0.0 when leaving the factory, and it is necessary to avoid correcting the correct appearance to incorrect when using.
|
More on that
|
Delta's inverter model selection
1. VFD-B series
This series has a variety of communication voltage standard model options, in addition to providing a variety of I/O signal functions, and can supply the appropriate current and voltage vector value according to the external load torque, to meet the needs of customers with high quality and low price.
...
|
|
Delta unveiled the ASDA-A2 series of AC servo motors and drives
New Delhi, September 2, 2010 – Delta Group, the world's largest supplier of switching power supplies and brushless DC fans, is committed to innovation, energy efficiency and environmental protection, and has launched a new and advanced high-performance ASDA-A2 series of servo motors and servo drives for motion control and networking in India.
|
|
Delta's active front-end inverter partner
The ubiquity of AC drives brings significant energy savings to industrial applications. However, the high-frequency switching signal generated by the inverter is easy to form electromagnetic disturbance, which affects the power quality. It is especially significant in occupations with large loads such as lifting and elevators.
At this time, the inverter ...
|
|
Measures to avoid soft failure of inverters - Delta
The ways to reduce the soft fault of the inverter are: 1. Detect the overvoltage and undervoltage of the inverter; 2. Detecting overcurrent is the most frequent phenomenon of frequency conversion alarm.
Generally, the overvoltage alarm is generally presented at the time of shutdown, and the primary reason is that the deceleration time is too short or the braking resistance and braking unit have ...
|
|
Debugging Delta's inverter method
1. Acceleration and deceleration time
The acceleration and deceleration time is usually confirmed by the rise and fall of the frequency setting signal. In the commissioning of Delta inverters, it is often used to set a long acceleration and deceleration time according to the load and experience value, and the frequency rise rate of the motor must be constrained when it accelerates to avoid overcurrent. When slowing down, ...
|
|
Delta's servo brake circuit wiring method
The wiring method of the braking circuit of the Delta servo is to short the brake resistor inside the driver at the P and C terminals of the Delta servo. The brake of the motor is directly connected to the external 24V drive, which is controlled by an external circuit.
Delta servo is developed according to the needs of customers who use different machinery; Provide a full range of ...
|
|
Mitsubishi's MHIET energy storage system, Delta, helped to solve the problem
Battery Management Solution Factory - Delta released the Mitsubishi Heavy Industries Group's star product, Mitsubishi Heavy Industries Group's three-power transformer hybrid one-power transformer system, proposing a high-quality method. This power transformer system is currently used at Mitsubishi Electric Manufacturing Plant in Aihara City, Kanagawa Prefecture, Japan.
|
|
Delta's servo protection parameters are written
A3, B3 servo
P5-97 Motion Control Mobilization Commands
0x0003 Maintenance Activation (Successful Return 0x1003)
0x0004 Maintenance Waiver (Successful Return 0x1004)
If the wrong cipher code is entered, the error code Ennn will be sent back to exempt the loss, during which nnn indicates that there is a ...
|
|
The output of the inverter is not short-connected to the power frequency
1. To switch the motor of the power frequency, the parking method is set to free parking, and it is important not to park softly
2. Intercept the contactor of the motor from the output end of the inverter, and the control stop button and the inverter parking button are the same composite button, that is, when the inverter is pressed, the inverter parking will be followed by the contactor line.
|
|
Delta's soft starter component role
The soft starter is a device used to control the start and stop of the motor, which is composed of a number of components, including the soft starter controller, the soft starter conditioner, the soft starter power supply, the soft starter input and output module, the soft starter interface module, etc.
...
|
|
Analysis of abnormal operation of Delta inverter
There are many setting parameters of the inverter, each parameter has a certain selection range, and the phenomenon that the inverter can not operate normally is often encountered in the application due to the improper setting of a single parameter, so the relevant parameters must be set correctly.
...
|
|
Delta's key steps in inverter maintenance
First, the maintenance of the inverter must first check whether the sound in the operation of the motor has changed abnormally, including, whether the motor is in operation to form a sensation.
2. Check whether the natural environment of the inverter installation has changed. For example, whether the operating temperature is normal. Learn more about Delta's inverter ...
|
|
Synchronous control parameter setting method for two or more inverters - Delta
Step 1
Two inverters, two wires, and one power supply.
Step 2
The inverter wiring defines the two inverters as a master and a slave respectively, the host port 485A is connected to the slave port 485A, and the host port 485B is connected to the slave port 485B.
...
|
|
The reason why the circuit breakers of multiple stages trip together is Delta
Short-circuit maintenance (overload maintenance) is an important function of circuit breakers, and the reason why this function is achieved is that the circuit breaker senses the temperature in the circuit through a thermal iron plate. Once the temperature in the circuit is too high, it is transmitted to the mechanical mechanism in the circuit breaker for trip maintenance.
...
|
|
Inverter performance test method - Delta
As we all know, the inverter has many maintenance functions, such as overcurrent, overvoltage, overload maintenance and so on. With the continuous improvement of industrial automation, frequency converters have also been widely used. This article will explain to you how to use a multimeter to measure the quality of the inverter.
Need...
|
|
What are the series of Delta inverters?
1:VFD-EL,VFD-S,VFD-L,VFD-C200
Voltage 220V, 380V, power scale 100W-7.5kw
The above series are Delta's simple inverters, commonly known as economical inverters, which are used for small fans and pumps, conveyor belts on food and pharmaceutical machinery, etc., and are used for abbreviated ...
|
|
Voltage regulator selection method - Delta inverter
1. Capacity safety factor
The AC regulated power supply is based on the output apparent power (kVA) as the nominal rated capacity, and the load is not purely resistive under normal circumstances, that is, the power factor COS¢≠1, and the active power that the regulator can output in practice kW = capacity (kVA) × COS¢. So in the real ...
|
|
Analysis of inverter application problems - Delta
1. Dealing with harmonic problems
The treatment of harmonic problems is to block the propagation path of the disturbance and press the higher harmonics on the source of the disturbance.
Interception of the transmission of disturbances can be carried out in the following ways:
1) Intercept the common grounding wire, propagation and disturbance path, the grounding of the power line and the grounding of the control line ...
|
|
Inverter encoder role - Delta
In the case of low speed accuracy requirements or small load changes, the inverter can be selected. The U/f control method refers to the method of controlling the frequency and voltage of the inverter. The rotational speed change in this control method is done by changing the set value of the frequency.
...
|
|
Failure analysis of Delta inverter VFD-VL series
Fault 1: Overcurrent in acceleration
Clarification: Overcurrent in acceleration
Solution 1: Check whether the wiring from U-V-W to the motor is poorly insulated;
2: Increase acceleration and deceleration time;
3: Replace the inverter with a larger output capacity;
4: Reduced (P54) torque ...
|
|