Analysis of abnormal operation of Delta inverter

Create Date: 2024-8-30 12:03:23|Source: Delta/Delta

There are many setting parameters of the inverter, each parameter has a certain selection range, and the phenomenon that the inverter can not operate normally is often encountered in the application due to the improper setting of a single parameter, so the relevant parameters must be set correctly.

                               Analysis of abnormal operation of Delta inverter

1. Manipulation method

i.e. speed manipulation, rotation distance manipulation, PID manipulation, or other methods. After adopting the control method, it is generally necessary to perform static or dynamic identification according to the control accuracy.

2.*** Low working frequency

That is, the motor works at a small speed, when the motor works at a low speed, its heat dissipation performance is very poor, and the motor works at a low speed for a long time, which will cause the motor to burn out. And at low speeds, the current in the cable will also increase, which will also cause the cable to heat up.

3.*** High working frequency

The general frequency converter has a large frequency to 60Hz, and some even to 400 Hz, and the high frequency will make the motor work at high speed, which is for the general motor, its bearing can not work at a long-term over-rated speed, and whether the rotor of the motor can accept such centrifugal force.

4. Carrier frequency

The higher the carrier frequency setting, the greater the weight of the higher harmonics, which is closely related to the length of the cable, the heating of the motor, the heating of the cable and the heating of the inverter.

5. Motor parameters

The inverter sets the power, current, voltage, speed, and maximum frequency of the motor in the parameters, and these parameters can be directly obtained from the motor nameplate.

6. Frequency hopping

At a certain frequency point, resonance may occur, especially when the whole device is relatively high; When operating the compressor, it is necessary to prevent the surge point of the compressor.

7. Acceleration and deceleration moments

The acceleration time is the time required for the output frequency to rise from 0 to the highest frequency, and the deceleration time is the time required to decrease from the largest frequency to 0. Acceleration and deceleration times are usually confirmed by the rise and fall of the frequency setting signal. When the motor is accelerating, the rise rate of the frequency setting must be constrained to prevent overcurrent, and when the motor is decelerating, the fall rate must be constrained to prevent overvoltage.

Speed up the time setting requirements: the acceleration current is constrained below the overcurrent capacity of the inverter, so that the overflow will not cause the inverter to trip; The key points of the deceleration time setting are: to prevent the voltage of the lubricating circuit from being too large, and not to cause the regenerative overvoltage to stall and trip the inverter. The acceleration and deceleration time can be calculated according to the load, but in the debugging, it is often used to set a longer acceleration and deceleration time according to the load and experience, and investigate whether there is an overcurrent and overvoltage alarm after starting and stopping the motor; Then the acceleration and deceleration time is gradually shortened, and the alarm does not occur in the work as the criterion, and the operation is repeated several times to confirm the best acceleration and deceleration time.

8. Torque increase

Also known as torque compensation, it is a method to increase the low frequency range f/V in order to compensate for the decrease in torque at low speed caused by the resistance of the stator winding of the motor. When set to active, the voltage at the time of acceleration can be actively increased to compensate for the starting torque, so that the motor can be accelerated smoothly. If manual compensation is used, the best curve can be selected according to the load characteristics, especially the starting characteristics of the load. Regarding the variable torque load, if it is not selected properly, the output voltage at low speed will be too high, and the phenomenon of wasting electric energy will be presented, and even the phenomenon that the current is large when the motor is started with a load, and the speed cannot go up.

9. Electronic thermal overload maintenance

This function is set to maintain the overheating of the motor, which is that the CPU in the inverter calculates the temperature rise of the motor according to the working current value and frequency, and then performs overheating maintenance. This function is only applicable to the occasion of "one to one", and in the case of "one to many", thermal relays should be installed on each motor.

Electronic Thermal Maintenance Setpoint (%) = [Motor Rated Current (A) / Inverter Rated Output Current (A)]×100%.

10. Frequency Constraints

That is, the upper and lower amplitudes of the output frequency of the inverter. Frequency restriction is a maintenance function to prevent misoperation or external frequency setting signal source from malfunctioning, which causes the output frequency to be too high or too low, so as to prevent damage to the equipment. In use, it can be set according to the actual situation. This function can also be used for speed limiting, such as the belt conveyor, because the material is not too much, in order to reduce the wear and tear of machinery and belt, the inverter can be driven, and the upper frequency of the inverter is set to a certain frequency value, so that the belt conveyor can work at a fixed, lower operating speed.

11. Bias frequency

Some are also known as deviation frequency or frequency deviation setting. Its purpose is to adjust the output frequency when the frequency is set by an external analog signal (voltage or current), and the output frequency can be adjusted when the frequency setting signal is low. When the frequency setting signal is 0%, the deviation value can be in the range of 0 - fmax, and some inverters (such as Mingdianshe and Sanken) can also set the bias polarity. If the output frequency of the inverter is not 0Hz but xHz when the frequency setting signal is 0% in the debugging, then the bias frequency can be set to negative xHz at this moment to make the output frequency of the inverter 0Hz.

12. Frequency setting signal gain

This function is only useful when setting the frequency with an external analog signal. It is used to compensate for the inconsistency between the externally set signal voltage and the internal voltage (+10V) of the inverter; At the same time, it is convenient to imitate the selection of the set signal voltage, set the punctuality, when the imitation input signal is large (such as 10v, 5v or 20mA), find the frequency percentage that can output the f/V graph and set it as a parameter; If the external setting signal is 0 - 5V, if the output frequency of the inverter is 0 - 50Hz, the gain signal can be set to 200%.

13. Torque constraint

There are two types of driving torque constraint and brake torque restraint. It is based on the output voltage and current values of the inverter, and the torque is calculated by the CPU, which can significantly improve the shock load recovery characteristics during acceleration and deceleration and constant speed operation. The torque restraint function enables active acceleration and deceleration control. Assuming that the acceleration and deceleration time is less than the load inertia time, the motor can also be guaranteed to actively accelerate and decelerate according to the torque setting value.

The driving torque function provides a strong starting torque, in the steady-state operation, the torque function will control the motor to deteriorate, and the motor torque is constrained within the largest set value, when the load torque suddenly increases, even when the acceleration time is set too short, it will not cause the inverter to trip. When the acceleration time is set too short, the motor torque will not exceed the maximum set value. A large drive torque is good for starting, so it is better to set it to 80 - 100%.

The smaller the braking torque setting value, the greater the braking force, which is suitable for the occasion of rapid acceleration and deceleration, such as the overvoltage alarm phenomenon when the braking torque setting value is set too much. If the braking torque is set to 0%, the total amount of regeneration applied to the main capacitor can be close to 0, and then the motor can be decelerated to a stop without using a braking resistor when decelerating. However, on some loads, such as when the braking torque is set to 0%, the phenomenon of short time and idle will appear when decelerating, resulting in repeated start of the inverter, and the current will fluctuate greatly, and the inverter will trip when it is severe, which should be noted.

More on that
Delta's Ultron NT series UPS escorts flight safety at international airports Delta's Ultron NT series UPS escorts flight safety at international airports

The rapid development of the national economy has opened up a broad shopping mall space for the growth of the civil aviation industry. In order to meet the surge in the number of flights, an international airport in Northwest China has invested in the third phase of the expansion project, and has been listed as the "number one project" for civil aviation development and the "benchmark demonstration project" for national civil aviation.

Debugging method of Delta servo motor Debugging method of Delta servo motor

1. Initialize parameters Before wiring, initialize the parameters. On the control card: select the control method; Reset the PID parameter to zero; When the control card is powered on, the enable signal is closed by acquiescence; Save this condition to make sure that the control card ...

Delta's high-performance servo ASDA-A3 series is a new product Delta's high-performance servo ASDA-A3 series is a new product

With the rapid development of automation technology and shopping malls, customers have higher and higher requirements for the speed, accuracy and function diversification of servo products. In order to get used to the needs of shopping malls, recently, Delta launched the high-performance motion control high-end AC servo system ASDA-A3 series ...

Introduction to Delta's RH series switching power supply Introduction to Delta's RH series switching power supply

Delta's RH series switching power supply, RH series switching power supply is a high-quality power supply product series planned by Delta Power for industrial applications, with the characteristics of high rate, high reliability and high function. This series of products has a wide range of input voltages and can be applied to a variety of power input ...

Delta's inverter model selection Delta's inverter model selection

1. VFD-B series This series has a variety of communication voltage standard model options, in addition to providing a variety of I/O signal functions, and can supply the appropriate current and voltage vector value according to the external load torque, to meet the needs of customers with high quality and low price. ...

The importance of harmonic control - Delta inverter The importance of harmonic control - Delta inverter

With the rapid development of the electronic and electrical industries, the demand for magnetic materials has promoted the world's huge industrial clusters. In the process of producing magnetic materials, many manufacturers are facing a great dilemma: the production of magnetic materials is mainly controlled by thyristor rectifier furnaces such as bell furnaces and nitrogen rotary furnaces.

Delta's servo motor maintenance and safety measures Delta's servo motor maintenance and safety measures

Delta's servo motor system is planned for industrial use, and it is necessary to have a sufficient understanding of the motor standards and operation manuals before operating the motor. For the safety of the operator and equipment, and to ensure that the motor can be used correctly, please read this safety precaution carefully before installing the machine. ...

Delta inverter repair steps Delta inverter repair steps

Delta inverters still have a certain influence in the industry, but even if the reputation is good, it will inevitably show some failures. Let's take a look. ...

Delta's inverter product model Delta's inverter product model

Delta's VFD inverters have established extensive brand awareness in industrial automation stores. Each series of products is designed for different operating needs such as torque, loss, overload, overspeed operation, etc., and is adjusted according to the characteristics of different industrial machinery; It can provide customers with a variety of choices, and a wide range of ...

Inverter encoder role - Delta Inverter encoder role - Delta

In the case of low speed accuracy requirements or small load changes, the inverter can be selected. The U/f control method refers to the method of controlling the frequency and voltage of the inverter. The rotational speed change in this control method is done by changing the set value of the frequency. ...

Delta's touch screen controls the inverter method Delta's touch screen controls the inverter method

1. The touch screen is controlled by PLC inverter 1. Now the general control of the inverter needs to use PLC to communicate with the inverter, read the information of the inverter, and then the touch screen communicates with the PLC in order to complete the control of the inverter to start, stop, and monitor the operation of the inverter.

Safety precautions for Delta servo motors Safety precautions for Delta servo motors

Delta's servo motor system is planned for industrial use, and it is necessary to have a full understanding of the motor standards and operation manuals before operating the motor. For the safety of the operator and the mechanical equipment, and to ensure that the communication motor can be used correctly, please read this safety precaution before installing the machine. ...

The basic control loop of Delta's inverter The basic control loop of Delta's inverter

There are two fundamental circuits for communicating with external signals: analog and digital: 1. 4-20mA current signal loop (imitation); 1 - 5V/0 - 5V voltage signal loop (imitation). 2. Switch signal circuit, inverter start and stop command, forward rotation command, etc.

Wind turbine inverter speed regulation effect - Delta Wind turbine inverter speed regulation effect - Delta

What is the effect of speed regulation of fan inverter? According to the query materials, in industrial production, the throttling loss of the damper, baffle and other related equipment of the fan, as well as the protection and maintenance costs account for 7%-25% of the production cost.

A brief introduction to Delta's inverters and their models A brief introduction to Delta's inverters and their models

Delta's VFD drives have now established a wide range of brand awareness in the industrial automation market. Each series of products is designed for different operation needs such as torque, loss, overload, overspeed work, etc., and is adjusted according to different industrial machinery attributes; It can provide customers with a variety of choices, and a wide range of ...

The inverter needs to be equipped with a braking resistor-Delta The inverter needs to be equipped with a braking resistor-Delta

The inverter is equipped with a braking resistor, mainly to consume part of the energy on the DC bus capacitor through the braking resistor to avoid the voltage of the capacitor being too high. Theoretically, if the capacitor stores a lot of energy, it can be used to release it to drive the motor to avoid energy waste, but the capacity of the capacitor is limited.

Pulse control wiring method for Delta servo drives Pulse control wiring method for Delta servo drives

Parameter settings P1-XX are the basic parameters P1-00 pulse method selection, *** bit selection is 2, that is, pulse train + direction P1-00 signal logic picking, the third digit is selected as 0 or 1, which is the positive logic or anti-logic, X0XX or X1XX P1-01 Control form selection, pick ...

The technical advantages of the three-axis positioner - Delta The technical advantages of the three-axis positioner - Delta

1. The welding station is actively handed over, and the operator has been loading and unloading parts in a fixed position, which effectively reduces the labor and logistics intensity of the operator, and the welding products of the whole set of equipment have strong compatibility and strong automatic welding scalability. 2. All ...

Characteristics of common models of Delta inverters Characteristics of common models of Delta inverters

Delta MS300 Inverter Series: Delta's compact standard vector-operated inverter MS300 combines the advantages of miniaturization, high functionality, high trust, and simple installation, transforming every investment in industrial resources into abundant results. Optimized structure with lock-free screw terminals to plan the supply of bento ...

Delta's Smart series of micro-modules help transform high-speed tunnel networks Delta's Smart series of micro-modules help transform high-speed tunnel networks

Recently, Delta's Smart series of micro-modular data center processing solutions successfully assisted the smooth implementation of a provincial tunnel network transformation project in a province. The project has set up a series of safety operation networks such as video, lights, signals, networks, rescues, and alarms for the safe operation of key roads in the province.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top