What are the series of Delta inverters?

Create Date: 2024-8-30 12:03:23|Source: Delta/Delta

1:VFD-EL,VFD-S,VFD-L,VFD-C200

Voltage 220V, 380V, power scale 100W-7.5kw

The above series are Delta's simple inverters, commonly known as economical inverters, which are used for small fans and pumps, conveyor belts on food and pharmaceutical machinery, etc., for simple speed regulation.

                                 What are the series of Delta inverters?

  2:VFD-M,VFD-E,VFD-MS300,VFD-MH300,VFD-CP2000

Voltage single-phase 200V, three-phase 220V, 380V, power scale 0.4kw-400kw

The above series are Delta's light-duty inverters, commonly known as general application inverters, which are mainly used in fans and pumps, central air conditioners, east-west machine tools, textile machinery, woodworking machinery, lifting machinery, food and medical equipment, etc

  3:VFD-B,VFD-C2000,VFD-VE,VFD-VL

Voltage single-phase 220V, three-phase 220V, 380V, power scale 0.75kw-400kw

The above series are Delta vector inverters, commonly known as heavy-duty inverters, vector inverters, which are mainly used for large fan pumps, precision machining, lifting cranes, air compressed air, spiral fans, food and medical treatment, wire drawing machines, printing and dyeing, elevators, engraving, milling machines, etc
More on that
Inverter Fault Repair Test Method - Delta Inverter Fault Repair Test Method - Delta

Static quizzes 1. Test the rectifier circuit Find the P and N ends of the DC power supply inside the inverter, adjust the multimeter to the resistance X10 gear, connect the red watch rod to P, and separate the black watch rod to R, S, T. Instead, connect the black watch rod to the P...

Precautions for Delta's DPA pressure sensor Precautions for Delta's DPA pressure sensor

1. When the device is installed, leave the place with high voltage and strong high-frequency noise to prevent disturbance. Prevent use in places where the following conditions occur: (a) Excessive dust and corrosive gases; (b) high humidity and very high radiation; (c) ...

Delta's soft starter component role Delta's soft starter component role

The soft starter is a device used to control the start and stop of the motor, which is composed of a number of components, including the soft starter controller, the soft starter conditioner, the soft starter power supply, the soft starter input and output module, the soft starter interface module, etc. ...

The function in the process of using the inverter cabinet - Delta The function in the process of using the inverter cabinet - Delta

Inverter cabinet is an industrial control equipment that can be widely used in fire fighting, daily constant pressure water supply and drainage, agricultural sprinkler irrigation pipe network pressurization, urban music fountain active water supply control, HVAC cold and hot water circulation control and other occasions. In addition, it also has a variety of maintenance functions such as: short circuit, overload, phase loss, etc.

A number of Delta's new high-end power supply products were unveiled at CMEF A number of Delta's new high-end power supply products were unveiled at CMEF

Delixi Electric's newly launched CDQ1F series PC-level excitation active transfer switch, with more complete specifications and stronger functions, the power-off time can be shortened to less than 0.1s, escorting the continuous use of electricity in important places! CDQ1F Active ...

The energy-saving principle of inverter - Delta The energy-saving principle of inverter - Delta

In order to ensure the reliability of production, all kinds of production machinery are designed with power drive, and there is a certain surplus when designing and matching power drive. When the motor cannot operate at full load, in addition to reaching the power drive requirements, the residual torque increases ...

Safety precautions for Delta servo motors Safety precautions for Delta servo motors

Delta's servo motor system is planned for industrial use, and it is necessary to have a full understanding of the motor standards and operation manuals before operating the motor. For the safety of the operator and the mechanical equipment, and to ensure that the communication motor can be used correctly, please read this safety precaution before installing the machine. ...

Synchronous control parameter setting method for two or more inverters - Delta Synchronous control parameter setting method for two or more inverters - Delta

Step 1 Two inverters, two wires, and one power supply. Step 2 The inverter wiring defines the two inverters as a master and a slave respectively, the host port 485A is connected to the slave port 485A, and the host port 485B is connected to the slave port 485B. ...

Introduction to Delta's PLC maintenance knowledge Introduction to Delta's PLC maintenance knowledge

1. Delta's PLC power on running light does not light up, and the ERROR flashes, the reason may be: no program 2. Delta's PLC cannot communicate with the computer, which may be: RS23 port is broken 3. Delta's PLC power light does not light up: The power supply is bad ...

Precautions for the installation environment of the inverter - Delta inverter Precautions for the installation environment of the inverter - Delta inverter

(1) Ambient temperature: The inverter is the same as other electronic equipment, and has certain requirements for the ambient temperature, which is generally "-10-+40°C". Because the inverter is a high-power electronic equipment, it is easy to be affected by the operating temperature, but in order to ensure the safety of the inverter...

Features of two-phase electric fan inverter - Delta Features of two-phase electric fan inverter - Delta

With the continuous development of science and technology, there are more and more types of domestic machinery and equipment, and the upgrading of equipment is getting faster and faster. So what are the characteristics of two-phase electric fan inverter and whether it is worth choosing for enterprises. ...

Cause of Servo Motor Failure – Delta Cause of Servo Motor Failure – Delta

1. The motor is broken shaft 1. The cause of the problem (1) Unreasonable mechanical design leads to excessive radial load force; (2) The load end is stuck or severely overloaded; (3) The motor and reducer are not centered when installed. 2. Eliminate problems (1) Check the ...

Several veins of the inverter circuit - Delta inverter Several veins of the inverter circuit - Delta inverter

1. Vibration circuit: the leakage-source and R4 of the main winding N1 and Q1 of the switching transformer are the channels of the power supply operation current; R1 provides the starting current; The self-powered windings N2, D1, and C1 constitute the power supply voltage of the vibrating chip. The normal operation of these three links is the prerequisite for the power supply to vibrate.

Delta's active front-end inverter partner Delta's active front-end inverter partner

The ubiquity of AC drives brings significant energy savings to industrial applications. However, the high-frequency switching signal generated by the inverter is easy to form electromagnetic disturbance, which affects the power quality. It is especially significant in occupations with large loads such as lifting and elevators. At this time, the inverter ...

Inverter environmental installation requirements and methods - Delta inverter Inverter environmental installation requirements and methods - Delta inverter

1. The environmental requirements of the inverter Ambient temperature - 10 °C - 40 °C; Ambient humidity: The relative humidity does not exceed 90% (no condensation); Other occasions that require no direct sunlight, no corrosive gas and flammable gas, and less dust, with an altitude of less than 1000m. ...

Description of Delta inverter problems and solutions Description of Delta inverter problems and solutions

Problem Description: What is stall avoidance? Solution(s): If the given acceleration and deceleration time is too short, the output frequency of the inverter changes faster than the motor speed, and the inverter will stop working due to overcurrent, which is called stalling. In order to make the motor ...

Method for measuring temperature rise during reducer operation - Delta Method for measuring temperature rise during reducer operation - Delta

The thermometer method and resistance method can be used to measure the temperature rise of each part of the reducer. 1) Thermometer method: This is the easiest way to measure the temperature directly, and it is commonly measured by an alcohol thermometer. When measuring, the thermometer can be placed close to the ...

Delta servo system composition Delta servo system composition

The servo system is mainly composed of a servo controller, a drive circuit, a servo motor and the corresponding reaction testing equipment. (1) Servo motor Servo motor refers to the motor that controls the mechanical components in the servo system, and the servo motor has an encoder inside, which can respond to the movement in real time.

Delta's inverter speed regulation application site Delta's inverter speed regulation application site

Inverter is a kind of speed regulating device, where to use the motor speed regulation, especially asynchronous motor speed regulation, will use the inverter, now mainly in industrial equipment has been used on a large scale, because the motor is the heart of the industry, and the three-phase asynchronous motor occupies the vast majority of the share, ...

Factors affecting Delta's inverter motors and countermeasures Factors affecting Delta's inverter motors and countermeasures

1. The influence of leakage current on the motor and countermeasures If the wiring length is very long, the stray capacitance between the wires will increase, resulting in leakage current. It will initiate overcurrent maintenance, increase leakage current or not ensure the correctness of the current display. The bad situation is that the inverter will ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top