Delta's inverter model selection

Create Date: 2024-8-30 12:03:23|Source: Delta/Delta

1. VFD-B series

This series has a variety of communication voltage standard model options, in addition to providing a variety of I/O signal functions, and can supply the appropriate current and voltage vector value according to the external load torque, to meet the needs of customers with high quality and low price.

                                  Delta's inverter model selection

2. VFD-S series

This series is known for its simple operation, providing useful function operation buttons, and using high-frequency switching skills to greatly reduce motor operating noise.

3. VFD-M series

This series provides medium to high horsepower power, and has the characteristics of light volume and quiet operation; In addition, the product adopts a variety of protection skills, which significantly improves the anti-interference ability of the whole machine.

4. VFD-L series

This series is specially planned for small horsepower motors, with built-in EMI filters to effectively suppress electromagnetic interference.

5. VFD-E series

This series adopts the planning of elastic modules, which is characterized by the built-in PLC function, which can be written and executed simple programs; It can also be equipped with special function expansion cards and communication cards, which is a representative of small horsepower type and meets the diversified needs of the industry.

6. VFD-EL series

This series adopts high-efficiency heat dissipation planning, can be installed side by side, with aluminum rail installation, space-saving, built-in market widely used functions, for the industry to use more choices.

7. VFD-C2000 series

This series has high-efficiency inverter drive skills with FOC control as the core, and its diversified drive control and modular planning, rich industrial use functions and self-diagnosis characteristics of simple maintenance and low failure rate are highly competitive in the market, effectively saving construction and operating costs for industrial and end customers, and enhancing competitiveness for users to grasp the opportunity to win!

8. VFD-CP2000 series

This series can improve the load torque response, meet the customer's wide range of variable torque load needs, and can adjust the input voltage in time to improve the overall efficiency in the environment of variable torque load, and provide appropriate operation and energy-saving plans for the environmental operation and maintenance of variable torque loads.

More on that
Introduction to the inverter selection strategy - Delta inverter Introduction to the inverter selection strategy - Delta inverter

1. Ability to adapt to the environment 1.1 Ability to adapt to grid voltage fluctuations When the motor on the bus starts in a group, when the largest motor unit on the bus starts, the influence on the operation of the inverter, which is related to the input voltage fluctuation range parameters promised by the inverter.

The cause of short circuit in power transformer - Delta The cause of short circuit in power transformer - Delta

Power transformers are used very frequently in daily livelihoods, in order to ensure the normal use of electricity, the safety and stability of the power transformer is the key point, once the transformer has a problem of prevention, it is necessary to quickly find out the cause and deal with it, take the transformer short circuit as an example, the damage caused by the insufficient treatment is ...

Reduce the failure rate of Delta's inverters Reduce the failure rate of Delta's inverters

Daily View Item 1: Check whether the sound of the motor changes abnormally during operation, including whether there is vibration during the operation of the motor. Project 2: Check if the environment of the inverter unit has changed. For example, whether the ambient temperature is normal. Familiar with Delta's inverter ...

Wind turbine inverter speed regulation effect - Delta Wind turbine inverter speed regulation effect - Delta

What is the effect of speed regulation of fan inverter? According to the query materials, in industrial production, the throttling loss of the damper, baffle and other related equipment of the fan, as well as the protection and maintenance costs account for 7%-25% of the production cost.

Debugging method of Delta servo motor Debugging method of Delta servo motor

1. Initialize parameters Before wiring, initialize the parameters. On the control card: select the control method; Reset the PID parameter to zero; When the control card is powered on, the enable signal is closed by acquiescence; Save this condition to make sure that the control card ...

Installation requirements for inverter energy consumption braking - Delta inverter Installation requirements for inverter energy consumption braking - Delta inverter

(1) The wiring interval between the braking unit and the inverter, as well as between the braking unit and the braking resistor, should be as short as possible (the wire length should be less than 2m), and the wire cross-section should meet the requirements of the braking resistor discharge current. (2) The brake unit is working ...

Delta's MH300 series technical specifications Delta's MH300 series technical specifications

Outstanding drive characteristics The overload capacity is up to 150% / 60 seconds, 200% / 3 seconds, suitable for constant torque, variable torque, constant power and other loads Support induction motor, permanent magnet synchronous motor, optional PG card for high ...

How to use Delta's inverter operation How to use Delta's inverter operation

(1) When the speed of the motor is controlled by the Delta inverter, the noise and temperature rise of the motor are higher than that of the frequency of the motor. When the motor is running at low speed, because the speed of the motor blades is low, the temperature rise of the motor becomes high.

Delta's A2 server maintenance location controller is faulty Delta's A2 server maintenance location controller is faulty

Delta's A2 series servo system is one of the more common and used servers on the market today, and the following describes the fault details of the azimuth controller in the repair of Delta's A2 servo drive and the corresponding repair methods Delta ...

Inverter optocoupler device type - Delta Inverter optocoupler device type - Delta

1. One is a triode type photocoupler, such as PC816, PC817, 4N35, etc., which is commonly used in the output voltage sampling and error voltage amplification circuit of the switching power supply circuit, and is also used in the digital signal input loop of the inverter control terminal. The structure is the simplest, and the input side consists of a light-emitting two...

How to choose Delta's servo motor How to choose Delta's servo motor

When selecting a Delta servo motor, in principle, the selection should be based on the load conditions. There are two types of loads on the motor shaft, namely damping torque and inertial load. Both loads should be calculated correctly and their values should meet the following criteria:   1) When the machine is running with no load, in the whole speed range, Delta ...

Delta servo system composition Delta servo system composition

The servo system is mainly composed of a servo controller, a drive circuit, a servo motor and the corresponding reaction testing equipment. (1) Servo motor Servo motor refers to the motor that controls the mechanical components in the servo system, and the servo motor has an encoder inside, which can respond to the movement in real time.

Comparison of three speed regulation methods for Delta DC motors Comparison of three speed regulation methods for Delta DC motors

There are three speed regulation methods for DC motors: armature loop string resistance, armature voltage regulation and speed regulation, and weak magnetic field speed regulation. The three speed regulation methods can achieve stepless speed regulation. 1. Armature loop string resistance The applied resistor is connected into the armature circuit to achieve the purpose of speed regulation. Speed Direction: Add ...

The power frequency motor is not normally installed with the inverter hazard The power frequency motor is not normally installed with the inverter hazard

Installing a variable-frequency drive (VFD) on the power frequency motor can complete the accurate control and speed regulation of the motor, and improve the efficiency and accuracy of the motor. However, if not properly equipped and used, it may cause the following hazards: ...

Delta's PLC programmable controller product list Delta's PLC programmable controller product list

1. Programmable manipulator AH series Delta's AH series modular controllers provide automation system solutions for high-end applications. The AH series adopts a comprehensive modular design, and on the basis of Delta's research and development skills, it has developed ...

Problems with Delta's compact pressure transmitters Problems with Delta's compact pressure transmitters

1. The transmitter does not return to zero under no pressure? Answer: The cleaning method is to remove the transmitter from the device position, investigate whether the zero position is normal, and replace the pipeline sealing ring if it is normal. Check together whether the transmitter is perpendicular to the piping assembly, and if not, adjust the transmitter zero. ...

Delta-B series inverter inverter output module is damaged and the drive circuit is damaged Delta-B series inverter inverter output module is damaged and the drive circuit is damaged

Delta-B series inverter inverter output module is damaged and the drive circuit is seriously damaged: the drive integrated circuit T250V or burst, or the output terminal and the power supply ground are short-circuited, the filter capacitor is sprayed, the regulator tube is broken down or open, the resistance is open or the resistance value increases, and the circuit board carbonization is damaged.

Delta's inverter adjusts the motor speed mode Delta's inverter adjusts the motor speed mode

The speed control on Delta's inverter is mainly as follows: 1. Adjust the variable resistance directly from the surface of the Delta inverter 2. External analogue voltage or current signal to adjust 3. Take advantage of the multi-function of the inverter ...

Delta unveiled the ASDA-A2 series of AC servo motors and drives Delta unveiled the ASDA-A2 series of AC servo motors and drives

New Delhi, September 2, 2010 – Delta Group, the world's largest supplier of switching power supplies and brushless DC fans, is committed to innovation, energy efficiency and environmental protection, and has launched a new and advanced high-performance ASDA-A2 series of servo motors and servo drives for motion control and networking in India.

Delta's C2000 inverter has evolved completely Delta's C2000 inverter has evolved completely

For those who are familiar with Delta's automation, they know that Delta's inverters have two main series: "M300" and "C2000". "Compact Inverter M300 Series": This series has been introduced many times before, including MS300 (standard general-purpose type), MH300 (high power ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top