Siemens APT – PB1 Series FAQs
1. What are the installation methods of PB1 button?
PB1S and PB1L are fastened with metal screws, and PB1J and PL1 are fastened with plastic nuts.
2. PB1 series pushbuttons can be assembled with up to several sets of contact modules as standard
2*3=6
3. PB1S shell ...
|
|
Siemens APT current transformers – measures to reduce errors
The excitation current is the main cause of the error of the current transformer, so reducing the excitation current can reduce the error
(1) The core is made of materials with high permeability, because the magnetic properties of the core not only affect the ratio difference and angular difference, but also affect the saturation multiple.
(2) Increase the cross-section of the iron core and shorten the magnetic circuit.
|
|
Siemens APT relays – classified according to the protection characteristics of the relays
(1) Sealed relay: Relay with low leakage rate by welding or other methods to seal the contacts and coils in the cover and isolate them from the surrounding medium.
(2) Enclosed relay: A relay that is sealed (not sealed) with a cover to protect the contacts and coils. ...
|
|
Introduction to the characteristics of Siemens APT ZY2 miniature relay
1. Various specifications, with indicator light, with manual test button, with surge suppression loop and other functions
2. Coil control voltage DC6V-220V, AC6V-240V (50/60HZ)
3. The rail type is equipped with a variety of adaptation sockets
4. LED indicator, DC is green, AC is red
...
|
|
Siemens APT - AD16 series indicator frequently asked questions
1. Why does the indicator light still glow after the control power supply has been disconnected?
This situation is caused by the presence of interference voltage, and this problem can be solved by ordering our anti-interference indicator light
2. What are the operating hours of the AD16 series indicators?
More than 30000 small ...
|
|
Siemens APT current transformer – a common form of current transformer ratio
1. Multi-tap current transformer. The primary winding remains unchanged, and when winding the secondary winding, several taps are added to obtain a plurality of different transformation ratios. For example, two taps are added to the secondary winding, K1 and K4 are 800/1A, K1 and K3 are 600/1A, and K1 and K2 are 400/1A, that is, the transformation ratio is 400-600-800/1A...
|
|
Features of Siemens APT Relays – AC Relays
1. Since the current through the AC electromagnetic relay is a changing alternating current, the magnetic flux in the magnetic circuit also changes with the alternation (sinusoidal law instead of straight line law). The suction force of the armature is varied between 0 and the maximum, so the suction of the AC electromagnetic relay is pulsating, variing.
|
|
Siemens APT Relays – Components of Solid State Relays
Solid state relays consist of three parts: the input circuit, the isolation (coupling), and the output circuit.
Input circuitry
According to the different categories of input voltage, the input circuit can be divided into three types: DC input circuit, AC input circuit and AC and DC input circuit. Some input control circuits are also ...
|
|
Siemens APT current transformer – current transformer operating error
When the current transformer is finalized and its internal parameters are determined, the magnitude of the error will be affected by the secondary current (or primary current), secondary load, power factor, and frequency. These factors are called external factors, and the error of the current transformer in operation is mainly affected by these four factors.
...
|
|
Siemens APT Relays - Precautions for the use of solid state relays
1. When choosing the solid state used in the printed circuit board with small current specifications, because the lead terminal is made of high thermal conductivity material, the welding should be carried out under the condition that the temperature is less than 250 °C and the time is less than 10S.
|
|
Siemens APT Relays – classified by their operating principle or structural characteristics
(1) Electromagnetic relay: an electrical relay that works by using the suction force generated by the current in the input circuit between the electromagnet core and the armature.
(2) Solid relay: refers to a kind of relay in which electronic components perform their functions without mechanical motion components, and the input and output are isolated.
|
|
Siemens APT Relays – Classified by relay load
(1) Micro-power relay: when the contact open circuit voltage is DC 28V, the (resistivity) is 0.1A, 0.2A relay.
(2) Weak power relay: when the contact open circuit voltage is DC 28V, (resistivity) is 0.5A, 1A relay.
(3) Medium power relay ...
|
|
Siemens APT Current Transformer - The difference between voltage transformer and current transformer
The difference between the voltage transformer and the current transformer in terms of effect principle The primary difference is that the operating conditions are very different during normal operation, and the main performance is as follows:
1) The current transformer can be short-circuited twice, but it cannot be opened; The voltage transformer can be opened twice, but it must not be short-circuited
2) ...
|
|
Siemens APT limit switch - wiring method of limit switch
1. First of all, there is a general understanding of the knowledge of the limit switch, which is usually composed of a shell, an interconnection system and an operating head.
2. First of all, the limit switch should be set to the desired location, and then connected, in addition, it is necessary to figure out the meaning of different letters, such as NC for the long ...
|
|
Siemens APT Relays – Functions of High Voltage Relays
1. Control switch: The high-voltage relay can open or close the high-voltage circuit to achieve the purpose of controlling the work of the equipment.
2. Protection circuit: The high-voltage relay can monitor the current, voltage, temperature and other parameters inside the high-voltage circuit, and automatically cut off the circuit when the circuit is abnormal.
|
|
Siemens APT current transformer - inspection content of current transformer
1. Regularly check whether the current transformer is overheated, check whether there is discoloration in the terminal, and check whether there are sundries in the terminal box.
2. Check whether there is oil leakage in the oil level gauge in time to ensure that the oil level meets the use standard and there is no oil leakage.
|
|
Siemens APT relay - the cause and solution of the fault of the high-voltage relay
1. Some common faults of high-voltage relay coils
1. The common fault cause of the coil is often disconnected: whether the ultrasonic wave is used to clean the high-voltage relay, or whether the overvoltage is added to the coil will also promote the probability of the coil being disconnected.
2 ...
|
|
Siemens APT current transformer - precautions for the use of current transformer
1. The wiring of the current transformer should not present problems, otherwise it will lead to failure to operate normally, and there may be damage to the transformer. In this case, the primary winding needs to be connected in series with the measurement circuit, and the secondary winding needs to be connected in series with all the loads.
2. Estimation ...
|
|
Siemens APT Limit Switches - Introduction to the types and characteristics of limit switches
Conventional domestic travel switch
LX19-001/111 in the LX19 series, LXK3-20S/T in the LXK3 series, JLXK1 series JLXK1-111/411/511 in the conventional travel switch are the most representative.
|
|
Siemens APT warning light - the role of LED warning light in life
LED warning light function
1. The luminous method selection items are: solid light, shiny, burst flash, constant/shiny mix.
2. The installation base is: L rod, straight rod, folding, and barrel type.
Effect of LED warning light_Effect in different scenes
1. Construction unit
On the road ...
|