Siemens APT – PB1 Series FAQs

Create Date: 2024-8-30 12:03:23|Source: APT/Siemens Shanghai Ergong

1. What are the installation methods of PB1 button?

PB1S and PB1L are fastened with metal screws, and PB1J and PL1 are fastened with plastic nuts.

2. PB1 series pushbuttons can be assembled with up to several sets of contact modules as standard

  2*3=6

3. What kind of material is used in the PB1S housing?

Zinc-aluminum alloy.

4. How to install PB1 series button contact module?

The PB1 series pushbutton contact modules are snap-on mounted, allowing for quick installation and removal with a flathead screwdriver.

5. What is the high altitude range that the PB1 button adapts to?

PB1 series buttons are used normally at an altitude of no more than 2000 meters.

6. Is the PB1 series eco-friendly?

PB1 series buttons follow the concept of environmental protection, and all series of products are in line with EU RoHS standards.

7. Are the PB1S and PB1L seats interchangeable?

It is not interchangeable, the metal center seat can only be used with the PB1S series, and the plastic center seat can only be used with the PB1L series.

8. What is the maximum number of contact removal modules that can be installed on the PB1 series pushbuttons?

The PB1 series can realize up to 6 contact modules with momentary buttons, up to 4 contact modules with illuminated buttons, and up to 2 contact modules with trigger stop knobs.

9. What is the protection level of PB1 series products?

All PB1 series of push buttons can meet the protection level of IP65, and the protection level of contact module and illuminated module is IP20.

10. What is the positioning angle of the PB1 series knobs?

PB1 series knobs are divided into two positions and three positions according to the action position, the angle is -45°-+45° in the two positions, and the angle is -60° 0° +60° in the three positions

11. How many kinds of head materials are there for PB1 series button products?

2 kinds. S of metal and L of the metallized head

12. What is the agreed heating current of PB1 series buttons?

  10A

13. What is the mechanical life of PB1 series general buttons?

3,000,000 times

14. What is the electrical life of the PB1 series?

500,000 times Ie/AC-15 at6A/220V/230V minimum load: DC24V 5mA

15. What is the impact rating of PB1 series?

  IEC60068 2-27

16. What is the vibration resistance level of PB1 series?

  IEC60068 2-6

17. What is the contact material of the PB1 series buttons?

Silver-nickel alloys

18. What are the sizes of PB1S series buttons and trigger E-STOP knobs?

Only φ40mm specification is available

19. What is the brightness of the PL1-D series indicator?

  >=100cd/m^2

20. What is the protection level of PL1-D series indicators?

  IP65
Siemens APT – PB1 Series FAQs


More on that
Siemens APT - AD16 series indicator frequently asked questions Siemens APT - AD16 series indicator frequently asked questions

1. Why does the indicator light still glow after the control power supply has been disconnected? This situation is caused by the presence of interference voltage, and this problem can be solved by ordering our anti-interference indicator light 2. What are the operating hours of the AD16 series indicators? More than 30000 small ...

Siemens APT Relays – a commonly used detection method for high and low voltage relays Siemens APT Relays – a commonly used detection method for high and low voltage relays

1. Visual inspection method: observe the appearance of the relay by the naked eye, check whether it is damaged or deformed, observe whether the contacts are tightly contacted, and whether there are copper slag and other substances attached to the contacts. 2. Parameter detection method: use test instruments to detect the parameters of the relay, such as: ...

Siemens APT - LW39 series 10,000 revolutions FAQ Siemens APT - LW39 series 10,000 revolutions FAQ

1. What are the current specifications of universal transfer switches? At present, there are four forms: 10A, 16A, 25A, and 63A 2. What are the positioning angles of the universal transfer switch? At present, it is divided into four angles: 30°, 45°, 60° and 90° 3. There is no customer's ...

Siemens APT Pushbutton Switches - Introduction to the types of metal pushbutton switches Siemens APT Pushbutton Switches - Introduction to the types of metal pushbutton switches

Common types of metal button switches include self-locking switches, self-reset switches, knob gear switches, lever gear switches, locking switches, etc.; Because the metal button switch is small in size, easy to install, metal material, voltage can be used from 9-220V, and the appearance of metal texture ...

Introduction to the characteristics of Siemens APT ZY2 miniature relay Introduction to the characteristics of Siemens APT ZY2 miniature relay

1. Various specifications, with indicator light, with manual test button, with surge suppression loop and other functions 2. Coil control voltage DC6V-220V, AC6V-240V (50/60HZ) 3. The rail type is equipped with a variety of adaptation sockets 4. LED indicator, DC is green, AC is red ...

Siemens APT helps Tianjin's advanced manufacturing industry Siemens APT helps Tianjin's advanced manufacturing industry

Tianjin is a typical industrial city. Due to the steady progress of "three districts and one base", the advanced manufacturing industry has developed rapidly in recent years. Siemens APT brought a variety of low-voltage control products to the 14th China (Tianjin) International Industry Fair held from March 15-18. Siemens APT has launched the PB1...

Siemens APT warning light - the role of LED warning light in life Siemens APT warning light - the role of LED warning light in life

LED warning light function 1. The luminous method selection items are: solid light, shiny, burst flash, constant/shiny mix. 2. The installation base is: L rod, straight rod, folding, and barrel type. Effect of LED warning light_Effect in different scenes 1. Construction unit On the road ...

Siemens APT - x.R series relays frequently asked questions Siemens APT - x.R series relays frequently asked questions

1. Does the AC control relay have surge suppression? SR/NR/PR can produce AC with surge suppression circuits 2. How many types of thermal current specifications are there for our company's relays? 3A, 5A, 8A, 10A, 12A five current specifications 3. Surge suppression back ...

Siemens APT Relays - Maintenance Methods for Solid State Relays Siemens APT Relays - Maintenance Methods for Solid State Relays

1. The influence of the ambient temperature The load capacity of the solid state relay is greatly affected by the ambient temperature and its own temperature rise, during the use of the device, it should be ensured that it has good heat dissipation conditions, the rated working current of more than 10A products should be equipped with radiators, and the products above 100A should be dissipated.

Siemens APT current transformer - inspection content of current transformer Siemens APT current transformer - inspection content of current transformer

1. Regularly check whether the current transformer is overheated, check whether there is discoloration in the terminal, and check whether there are sundries in the terminal box. 2. Check whether there is oil leakage in the oil level gauge in time to ensure that the oil level meets the use standard and there is no oil leakage.

Siemens APT current transformer – current transformer operating error Siemens APT current transformer – current transformer operating error

When the current transformer is finalized and its internal parameters are determined, the magnitude of the error will be affected by the secondary current (or primary current), secondary load, power factor, and frequency. These factors are called external factors, and the error of the current transformer in operation is mainly affected by these four factors. ...

Siemens APT limit switch - wiring method of limit switch Siemens APT limit switch - wiring method of limit switch

1. First of all, there is a general understanding of the knowledge of the limit switch, which is usually composed of a shell, an interconnection system and an operating head. 2. First of all, the limit switch should be set to the desired location, and then connected, in addition, it is necessary to figure out the meaning of different letters, such as NC for the long ...

ALH-0.66 series transformer FAQ ALH-0.66 series transformer FAQ

1. What is the maximum voltage that can be used for an ALH transformer? AC low voltage up to 720V 2. Is there a protective grade product for ALH transformers? II-P AND III-P are available in both protective grades 3. What is the maximum primary current of ALH transformer? The maximum primary side current is 8 ...

Siemens APT Relays - a detailed introduction to the classification of relays Siemens APT Relays - a detailed introduction to the classification of relays

Classified according to the working principle or structural characteristics of relays: 1) Electromagnetic relay: an electrical relay that works by using the suction force generated by the current in the input circuit between the electromagnet core and the armature. 2) Solid state relay: refers to the electronic components that perform their functions without mechanical ...

Siemens APT Relays – The Cause of Solid State Relays Burnout Siemens APT Relays – The Cause of Solid State Relays Burnout

1. Poor design (low margin of voltage or current reservation during selection, insufficient heat dissipation conditions, etc.). 2. The fuse is too large or the fast fuse is not used as required. 3. The radiator is full of dust or the cooling fan fails. 4. Solid State Relay ...

Siemens APT current transformer - how to see the multiple of the current transformer Siemens APT current transformer - how to see the multiple of the current transformer

1. Most of the multiple values can be seen from the nameplate attached to the instrument, which will show the style of the value/value, which can be known by dividing the previous value by dividing the back value when calculating the standard core-piercing turns. If the actual number of turns of the grommet does not conform to the standard, then the multiple should be ...

Siemens APT Relays - Maintenance Methods for Solid State Relays Siemens APT Relays - Maintenance Methods for Solid State Relays

1. The influence of the ambient temperature The load capacity of the solid state relay is greatly affected by the ambient temperature and its own temperature rise, during the use of the device, it should be ensured that it has good heat dissipation conditions, the rated working current of more than 10A products should be equipped with radiators, and the products above 100A should be dissipated.

Siemens APT Relays – The difference between solid state relays and intermediate relays Siemens APT Relays – The difference between solid state relays and intermediate relays

First, the solid-state relay has no contacts and coils in the structure, which can be opened and closed at a high frequency and will not produce sparks, and has a long service life; Second, the intermediate relay is generally only used for the control loop, and cannot work with load, and will make a "pop" sound when it is sucked in; ...

Siemens APT Pushbutton Switches – How Many Types of Pushbutton Switches Are There? Siemens APT Pushbutton Switches – How Many Types of Pushbutton Switches Are There?

There are several types of pushbutton switches: Pushbutton switches can be classified according to the way they are protected and how they are operated. It can be divided into open type and protected type, as well as waterproof type and anti-corrosion type, etc. And explosion-proof, knob-type, key-type, emergency-type, are also its ...

Siemens APT current transformers – factors influencing the error of current transformers Siemens APT current transformers – factors influencing the error of current transformers

(1) The influence of the internal resistance R2 and leakage impedance X2 of the secondary coil on the error: when R2 increases, the specific difference and angular difference increase; As X2 increases, the specific difference increases, but the angular difference decreases. Therefore, to improve the error, R2 and the appropriate X2 value should be minimized. Due to the secondary coil internal resistance R2 and leakage ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top