Siemens APT Relays - Precautions for the use of solid state relays

Create Date: 2024-8-30 12:03:23|Source: APT/Siemens Shanghai Ergong

1. When using the solid state used in the printed circuit board with small current specifications, because the lead terminal is made of high thermal conductivity material, the welding should be carried out under the condition that the temperature is less than 250 °C and the time is less than 10S.

2. The selection of SSR for solid state relay with various load surge characteristics

The controlled load will generate a large inrush current at the moment of switching, and because the heat cannot be dissipated in time, it is likely to damage the internal thyristor of the SSR, so the user should analyze the surge characteristics of the controlled load when selecting the relay, and then select the relay. To make the relay be able to withstand this inrush current under the premise of ensuring steady-state operation, you can refer to the derating coefficient (at room temperature) of various loads in Table 2 when selecting.

If the selected relay needs to work in the occasion with high requirements for more frequent work, life and reliability, it should be multiplied by 0.6 on the basis of Table 2 to ensure reliable operation.

Generally, the above principles are followed in the selection, and the DC solid-state relay using the FET as the output device can be selected when the signal distortion is small at low voltage; For example, for AC resistive loads and most inductive loads, zero-crossing relays can be selected, which can prolong the life of the load and relay, and also reduce its own radio frequency interference. If it is used as a phase output control, a random solid state relay should be selected.

3. The influence of the ambient temperature

The load capacity of the solid state relay is greatly affected by the ambient temperature and its own temperature rise, in the process of installation and use, it should be ensured that it has good heat dissipation conditions, the rated working current of more than 10A products should be equipped with radiators, and products above 100A should be equipped with radiators and fans for strong cooling. During installation, attention should be paid to the good contact between the bottom of the relay and the radiator, and an appropriate amount of thermal grease should be considered to achieve the best heat dissipation effect.

If the relay works at high temperature for a long time (40°C-80°C), the user can consider derating to ensure normal operation according to the maximum output current and ambient temperature curve data provided by the manufacturer.

4. Over-current and over-voltage protection measures

When the relay is used, due to overcurrent and load short circuit, the internal output thyristor of the SSR solid state relay will be permanently damaged, and the fast fuse and protection type can be considered in the control loop (the product output protection should be selected for the selection of relay, with built-in varistor absorption circuit and RC buffer, which can absorb surge voltage and improve dv/dt resistance); Output protection can also be achieved by connecting an RC absorption loop and a varistor (MOV) at the output of the relay. The selection principle is 500V-600V varistor for 220V, and 800V-900V varistor for 380V.

5. Relay input loop signal

When the input voltage is too high or the input current is too large to exceed the rated parameters specified in the input, it can be considered to connect the voltage divider resistor in series at the input terminal or connect the shunt resistor at the input port in parallel, so that the input signal does not exceed its rated parameter value.

6. In specific use, the control signal and load should be stable, and the fluctuation should not be greater than 10%, otherwise voltage stabilization measures should be taken.

7. When installing and using, it should be kept away from electromagnetic interference and radio frequency interference sources to prevent the relay from malfunctioning out of control.

8. When the solid state relay is open and there is voltage at the load end, there will be a certain leakage current at the output end, which should be paid attention to when using or designing.

9. When the solid-state relay fails to be replaced, the original model or the product with the same technical parameters should be selected as far as possible to match the original application line and ensure the reliable operation of the system.
Siemens APT Relays - Precautions for the use of solid state relays

More on that
Siemens APT transformer – common faults and analysis of voltage transformers Siemens APT transformer – common faults and analysis of voltage transformers

(1) The insulation between the iron chips is damaged Problem: The temperature rises during operation. Possible causes of the problem: (1) Poor insulation between iron chips (2) The use of harsh environmental conditions or long-term operation at high temperature to promote the aging of insulation between iron chips. ( ...

Siemens APT relay - the main structural features of high and low voltage relays Siemens APT relay - the main structural features of high and low voltage relays

1. Electromagnet: The electromagnet of high and low voltage relay is usually composed of two parts: coil and core. When the high and low voltage relay inputs the electrical signal, the electromagnet coil will generate electromagnetic force, drive the iron core, and realize the on/off control of the relay. 2. Contact group: The contact group is a high and low voltage relay control ...

Siemens APT Relays – the working principle and function of relays Siemens APT Relays – the working principle and function of relays

How relays work Relays generally refer to electromagnetic relays, that is, mechanical actions. The working principle of the relay is essentially to use one loop (generally a small current) to control the on/off of another circuit (generally a large current), and in this control process, ...

Siemens APT current transformer - how to see the multiple of the current transformer Siemens APT current transformer - how to see the multiple of the current transformer

1. Most of the multiple values can be seen from the nameplate attached to the instrument, which will show the style of the value/value, which can be known by dividing the previous value by dividing the back value when calculating the standard core-piercing turns. If the actual number of turns of the grommet does not conform to the standard, then the multiple should be ...

Siemens APT Relays – classified by their operating principle or structural characteristics Siemens APT Relays – classified by their operating principle or structural characteristics

(1) Electromagnetic relay: an electrical relay that works by using the suction force generated by the current in the input circuit between the electromagnet core and the armature. (2) Solid relay: refers to a kind of relay in which electronic components perform their functions without mechanical motion components, and the input and output are isolated.

Siemens APT Relays – Protection Measures for AC Solid State Relays Siemens APT Relays – Protection Measures for AC Solid State Relays

1. Selection of voltage level and overvoltage protection of solid-state relay When the voltage peak value applied to the AC terminal of the solid state relay exceeds the maximum voltage peak that the AC solid state relay can bear, the components in the solid state relay will be broken down by the voltage and cause damage to the AC solid state relay, ...

Siemens APT Relays – Maintenance of high-voltage relays Siemens APT Relays – Maintenance of high-voltage relays

1. Regular cleaning: The relay needs to be cleaned regularly with dust and dirt to keep its surface clean and smooth. It can be cleaned with a clean cloth or brush, and detergents containing acids and bases should be avoided. 2. Check the wiring: The wiring of the relay needs to be fastened firmly, and the contact ...

Introduction to the features of the full range of Siemens APT metal button FM products Introduction to the features of the full range of Siemens APT metal button FM products

Seeking advanced, perfect and excellent Xijia APT to concentrate on research and development, and constantly change customs, the launch of the metal flat button indicator FM series is to complete the perfect integration of appearance and performance. Ultra-thin flat round device, metal shell and buttons, high-value appearance Product ...

Siemens APT Relays – The difference between solid state relays and intermediate relays Siemens APT Relays – The difference between solid state relays and intermediate relays

First, the solid-state relay has no contacts and coils in the structure, which can be opened and closed at a high frequency and will not produce sparks, and has a long service life; Second, the intermediate relay is generally only used for the control loop, and cannot work with load, and will make a "pop" sound when it is sucked in; ...

Siemens APT helps Tianjin's advanced manufacturing industry Siemens APT helps Tianjin's advanced manufacturing industry

Tianjin is a typical industrial city. Due to the steady progress of "three districts and one base", the advanced manufacturing industry has developed rapidly in recent years. Siemens APT brought a variety of low-voltage control products to the 14th China (Tianjin) International Industry Fair held from March 15-18. Siemens APT has launched the PB1...

Siemens APT relay - the main structural features of high and low voltage relays Siemens APT relay - the main structural features of high and low voltage relays

1. Electromagnet: The electromagnet of high and low voltage relay is usually composed of two parts: coil and core. When the high and low voltage relay inputs the electrical signal, the electromagnet coil will generate electromagnetic force, drive the iron core, and realize the on/off control of the relay. 2. Contact group: The contact group is a high and low voltage relay control ...

Siemens APT Relays – What should I pay attention to when selecting relays? Siemens APT Relays – What should I pay attention to when selecting relays?

1. When selecting a relay, it is necessary to understand the load and type of its contact, because the contact method of the relay of the same model is different, with multiple groups of contacts and single group contacts. When selecting a relay, you can choose the type of contact. 2. And in the peach ...

Siemens APT Relays – What are the types of protection relays? Siemens APT Relays – What are the types of protection relays?

Overcurrent Relay (OCR) It operates when a certain value or greater of current flows through. There are two elements: overcurrent detection (known as a timing element) and short-circuit current detection (as an instantaneous element). Earth Fault Overcurrent Relays (OCGR, GR) While...

Siemens APT current transformer – precautions for current transformers Siemens APT current transformer – precautions for current transformers

1. Before the installation of the open current transformer, it must be connected to the meter (or other measuring devices) for the second time to ensure that the transformer is not open for the second time; 2. Place all the open current transformers connected to the secondary line on the site and wait for installation; 3. If the on-site bus is electrical...

Siemens APT current transformer - classification of current transformer and its function Siemens APT current transformer - classification of current transformer and its function

1. Current transformers are classified according to the installation method According to the installation method, the current transformer can be divided into through-type current transformer, pillar type current transformer, bushing type current transformer, and busbar type current transformer. Through-type current transformer: used to pass through the screen or wall...

Siemens APT Relays - Selection Method for Solid State Relays Siemens APT Relays - Selection Method for Solid State Relays

1. When selecting the solid-state relay used in the printed circuit board with small current specifications, because the lead terminal is made of high thermal conductivity material, the soldering should be carried out under the condition that the temperature is less than 250 °C and the time is less than 10S.

Siemens APT Relays – The difference between signal relays and power relays Siemens APT Relays – The difference between signal relays and power relays

Signal relays are used more in secondary maintenance circuit circuits. It tells the right people exactly what is wrong with the maintenance. The power relay is a bit like a discriminant sentence in mathematics. When a constant is entered, the satisfactory and unsatisfactory conditions will output different results. Merit...

Siemens APT current transformer - working principle and characteristics of current transformer Siemens APT current transformer - working principle and characteristics of current transformer

How a current transformer works The principle of current transformer is based on the principle of electromagnetic induction. A current transformer is composed of a closed core and windings. It has a small number of turns on the primary side winding, stringed in the line where the current needs to be measured, so it often has the full current of the line ...

Siemens APT limit switch - wiring method of limit switch Siemens APT limit switch - wiring method of limit switch

1. First of all, there is a general understanding of the knowledge of the limit switch, which is usually composed of a shell, an interconnection system and an operating head. 2. First of all, the limit switch should be set to the desired location, and then connected, in addition, it is necessary to figure out the meaning of different letters, such as NC for the long ...

Siemens APT current transformer - what need to be paid attention to in the use of current transformer Siemens APT current transformer - what need to be paid attention to in the use of current transformer

1. The secondary side of the current transformer shall not be open when working. Due to the small secondary impedance of the current transformer, the secondary side of the current transformer is close to the short-circuit state during normal operation. When the secondary side is open, a high voltage will be induced, which endangers the safety of people and equipment. 2. Electricity ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top