1. Some common faults of high-voltage relay coils

1. The common fault cause of the coil is often disconnected: whether the ultrasonic wave is used to clean the high-voltage relay, or whether the overvoltage is added to the coil will also promote the probability of the coil being disconnected.

2. The common fault reasons for the lack of power engineering in the coil are: first of all, the working voltage of the high-voltage relay coil must be determined, and it is assumed that the working voltage of the power supply system to the coil is lower than the posture working voltage, which will cause the contact to be out of posture.

3. Common fault causes of coil optical rotation connection: check whether the diode equipped with the high voltage relay is equipped with optical rotation error, which will make the contact not operate.

4. Appear coil communication AC with; The DC DC power supply system is incorrect, and common fault reasons: if the AC voltage is added to the high-voltage relay coil of the AC coil, then there will be a hot coil, which is very likely to cause ablation, and if the AC current is added to the high-voltage relay coil of the DC coil, it will make the moving iron sheet vibrate continuously and then cannot work normally.

5. If a part of the coil is connected to the power supply for a long time, it will lead to the hot coil and the malignant transformation of the insulation layer, which will promote the common fault of the high-voltage relay posture.

Second, some common fault solutions for high-voltage relay coils

1. A simpler and better way is to disassemble and replace the high-voltage relay again.

2. There is also to determine the working voltage of the coil to prevent the working voltage supplied by the coil from being less than the working voltage.
Siemens APT relay - the cause and solution of the fault of the high-voltage relay

More on that
Siemens APT current transformer – wiring method of current transformer Siemens APT current transformer – wiring method of current transformer

1. The single wiring mode can only feedback the status of single-phase current. 2. Three-phase complete star wiring, usually used in transformer differential protection wiring. 3. The two-phase incomplete star wiring method is used frequently in daily work. 4. The two phases ...

Siemens APT Relays - Precautions for the use of solid state relays Siemens APT Relays - Precautions for the use of solid state relays

1. When choosing the solid state used in the printed circuit board with small current specifications, because the lead terminal is made of high thermal conductivity material, the welding should be carried out under the condition that the temperature is less than 250 °C and the time is less than 10S.

Siemens APT relays – classified according to the protection characteristics of the relays Siemens APT relays – classified according to the protection characteristics of the relays

(1) Sealed relay: Relay with low leakage rate by welding or other methods to seal the contacts and coils in the cover and isolate them from the surrounding medium. (2) Enclosed relay: A relay that is sealed (not sealed) with a cover to protect the contacts and coils. ...

Siemens APT Relays – What are the forms of protection relays? Siemens APT Relays – What are the forms of protection relays?

Rail protection relays A protective relay that works mainly as a result of accidents that occur in transmission lines. When this method works, the circuit breakers at both ends of the faulty line will be disconnected. Busbar protection relays A protective relay, mainly due to the power plant or transformer...

Siemens APT Relays – Protection Measures for AC Solid State Relays Siemens APT Relays – Protection Measures for AC Solid State Relays

1. Selection of voltage level and overvoltage protection of solid-state relay When the voltage peak value applied to the AC terminal of the solid state relay exceeds the maximum voltage peak that the AC solid state relay can bear, the components in the solid state relay will be broken down by the voltage and cause damage to the AC solid state relay, ...

Siemens APT transformer – common faults and analysis of voltage transformers Siemens APT transformer – common faults and analysis of voltage transformers

(1) The insulation between the iron chips is damaged Problem: The temperature rises during operation. Possible causes of the problem: (1) Poor insulation between iron chips (2) The use of harsh environmental conditions or long-term operation at high temperature to promote the aging of insulation between iron chips. ( ...

Siemens APT Relays – The Cause of Solid State Relays Burnout Siemens APT Relays – The Cause of Solid State Relays Burnout

1. Poor design (low margin of voltage or current reservation during selection, insufficient heat dissipation conditions, etc.). 2. The fuse is too large or the fast fuse is not used as required. 3. The radiator is full of dust or the cooling fan fails. 4. Solid State Relay ...

Siemens APT LA39 series button FAQ Siemens APT LA39 series button FAQ

1. What are the installation methods of LA39-A/B/C button? There are five types in total: the Z1 diagonal screw unit, the Z2 straight screw unit, the Z3 nut device with fastening screws, the Z4 nut device without fastening screws, and the Z5 quick and convenient one-handed device 2. LA39 series products can be used ...

Siemens APT current transformer - how to see the multiple of the current transformer Siemens APT current transformer - how to see the multiple of the current transformer

1. Most of the multiple values can be seen from the nameplate attached to the instrument, which will show the style of the value/value, which can be known by dividing the previous value by dividing the back value when calculating the standard core-piercing turns. If the actual number of turns of the grommet does not conform to the standard, then the multiple should be ...

Siemens APT relay - the main structural features of high and low voltage relays Siemens APT relay - the main structural features of high and low voltage relays

1. Electromagnet: The electromagnet of high and low voltage relay is usually composed of two parts: coil and core. When the high and low voltage relay inputs the electrical signal, the electromagnet coil will generate electromagnetic force, drive the iron core, and realize the on/off control of the relay. 2. Contact group: The contact group is a high and low voltage relay control ...

Siemens APT Relays – How to Choose Relays? Siemens APT Relays – How to Choose Relays?

1. The type and series of relay selection First of all, the type of relay is selected according to the work requirements of the object to be controlled or protected, and then the appropriate series is selected according to the sensitivity or accuracy requirements. When choosing a series, you should also pay attention to the compatibility of the relay with the system. (1) ...

Siemens APT Relays – The difference between signal relays and power relays Siemens APT Relays – The difference between signal relays and power relays

Signal relays are used more in secondary maintenance circuit circuits. It tells the right people exactly what is wrong with the maintenance. The power relay is a bit like a discriminant sentence in mathematics. When a constant is entered, the satisfactory and unsatisfactory conditions will output different results. Merit...

Siemens APT Pushbutton Switches - Introduction to the types of metal pushbutton switches Siemens APT Pushbutton Switches - Introduction to the types of metal pushbutton switches

Common types of metal button switches include self-locking switches, self-reset switches, knob gear switches, lever gear switches, locking switches, etc.; Because the metal button switch is small in size, easy to install, metal material, voltage can be used from 9-220V, and the appearance of metal texture ...

Siemens APT - LW39 series 10,000 revolutions FAQ Siemens APT - LW39 series 10,000 revolutions FAQ

1. What are the current specifications of universal transfer switches? At present, there are four forms: 10A, 16A, 25A, and 63A 2. What are the positioning angles of the universal transfer switch? At present, it is divided into four angles: 30°, 45°, 60° and 90° 3. There is no customer's ...

Siemens APT Current Transformers – How to view current transformers Siemens APT Current Transformers – How to view current transformers

1. Standardize current transformer: the top of the transformer verification is used as a standardizer, and the accuracy is usually more than two grades higher than that of the tested. 2. Load box: imitate the practice operation status of the tested transformer. 3. Transformer ...

Siemens APT Pushbutton Switches – How Many Types of Pushbutton Switches Are There? Siemens APT Pushbutton Switches – How Many Types of Pushbutton Switches Are There?

There are several types of pushbutton switches: Pushbutton switches can be classified according to the way they are protected and how they are operated. It can be divided into open type and protected type, as well as waterproof type and anti-corrosion type, etc. And explosion-proof, knob-type, key-type, emergency-type, are also its ...

Siemens APT Relays – Maintenance of high-voltage relays Siemens APT Relays – Maintenance of high-voltage relays

1. Regular cleaning: The relay needs to be cleaned regularly with dust and dirt to keep its surface clean and smooth. It can be cleaned with a clean cloth or brush, and detergents containing acids and bases should be avoided. 2. Check the wiring: The wiring of the relay needs to be fastened firmly, and the contact ...

Siemens APT Relays – the solution to common faults in solid state relays Siemens APT Relays – the solution to common faults in solid state relays

1. The simplest and most effective way is to use a new solid state relay. 2. The other is to determine the voltage of the coil to avoid the voltage provided by the coil being less than the operating voltage. 3. Check whether the polarity is reversed. 4. Reasonable power-on time for the solid state relay coil, if ...

Siemens APT transformer - the use of voltage transformer and precautions Siemens APT transformer - the use of voltage transformer and precautions

The voltage transformer output is usually 100V 1. The working impedance in the secondary circuit of the voltage transformer should not be too small to avoid overload operation. 2 Before connecting the circuit, the polarity of the voltage transformer should be verified. 3 After connecting the circuit, the secondary coil should be reliably grounded, ...

Siemens APT limit switches – the difference between proximity switches and travel switches Siemens APT limit switches – the difference between proximity switches and travel switches

01 The role is different Proximity switches are contactless switches with a long life and are suitable for "pass-through signals". The travel switch is also known as the limit switch, the travel switch and the limit switch are both position switches, but the travel switch can detect the stroke, and can be used as an input signal to control the circuit at a certain distance ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top