1. Since the current through the AC electromagnetic relay is a changing alternating current, the magnetic flux in the magnetic circuit also changes with the alternation (sinusoidal law instead of straight line law). The suction of the armature is varied between 0 and the maximum, so the suction of the AC electromagnetic relay is pulsating, and the change frequency is twice the AC frequency, and the suction of this pulsation will make the armature flutter, so measures should be taken in the structure to eliminate the flutter and affect the life of the relay
2. Because when the AC power passes through the core, the alternating magnetic flux is generated, so that the eddy current is generated in the core, and the magnetic field generated by the eddy current is opposite to the direction of the original magnetic flux, so that a part of the magnetic flux becomes a leakage flux and is lost, resulting in magnetic loss
3. In addition, the DC electromagnetic relay only has a back EMF at the moment of turning on the power supply or cutting off the power supply, and in a stable state, the current through the coil is only determined by the resistance, and the AC electromagnetic relay, even in a stable case, there is a back EMF, so the current of the AC relay is mainly not determined by the resistance, but by the inductive reactance of the coil, which shows that when calculating the AC relay circuit, the inductance of the coil AC electromagnetic relay coil current must be determined by the reactance (inductance) of the coil
|
More on that
|
Siemens APT Relays – Protection Measures for AC Solid State Relays
1. Selection of voltage level and overvoltage protection of solid-state relay
When the voltage peak value applied to the AC terminal of the solid state relay exceeds the maximum voltage peak that the AC solid state relay can bear, the components in the solid state relay will be broken down by the voltage and cause damage to the AC solid state relay, ...
|
|
Siemens APT current transformer - how to choose a current transformer?
First, the principle of primary parameter selection of current transformer
The rated primary current of the current transformer is determined by the actual load of the tested circuit, and the rated primary current of the current transformer should not be less than the rated primary current of the circuit.
|
|
Siemens APT Limit Switches - Introduction to the types and characteristics of limit switches
Conventional domestic travel switch
LX19-001/111 in the LX19 series, LXK3-20S/T in the LXK3 series, JLXK1 series JLXK1-111/411/511 in the conventional travel switch are the most representative.
|
|
Siemens APT Relays – How to Choose Relays?
1. The type and series of relay selection
First of all, the type of relay is selected according to the work requirements of the object to be controlled or protected, and then the appropriate series is selected according to the sensitivity or accuracy requirements. When choosing a series, you should also pay attention to the compatibility of the relay with the system.
(1) ...
|
|
Siemens APT helps Tianjin's advanced manufacturing industry
Tianjin is a typical industrial city. Due to the steady progress of "three districts and one base", the advanced manufacturing industry has developed rapidly in recent years. Siemens APT brought a variety of low-voltage control products to the 14th China (Tianjin) International Industry Fair held from March 15-18. Siemens APT has launched the PB1...
|
|
Siemens APT Pushbutton Switches - Introduction to the types of metal pushbutton switches
Common types of metal button switches include self-locking switches, self-reset switches, knob gear switches, lever gear switches, locking switches, etc.; Because the metal button switch is small in size, easy to install, metal material, voltage can be used from 9-220V, and the appearance of metal texture ...
|
|
Siemens APT Current Transformer - The difference between voltage transformer and current transformer
The difference between the voltage transformer and the current transformer in terms of effect principle The primary difference is that the operating conditions are very different during normal operation, and the main performance is as follows:
1) The current transformer can be short-circuited twice, but it cannot be opened; The voltage transformer can be opened twice, but it must not be short-circuited
2) ...
|
|
Siemens APT current transformer – the basis for whether the current transformer is damaged or the measurement is inaccurate
1. The inspection basis for whether the current transformer is damaged:
1. The basis for checking whether the polarity is damaged:
The primary winding of the current transformer is marked P1 and P2, and the secondary winding is marked as S1 and S2. If P1 and S1 are the same name, then this sign is called reduced polarity. Primary current from P1 ...
|
|
Siemens APT Relays - What are the classifications of high and low voltage relays?
1) Electromagnetic relay: an electrical relay that works by using the suction force generated by the circuit in the input circuit between the electromagnet core and the armature.
2) Solid relay: refers to a kind of relay in which electronic components perform their functions without mechanical motion components, and the input and output are isolated. ...
|
|
Siemens APT warning light - the role of LED warning light in life
LED warning light function
1. The luminous method selection items are: solid light, shiny, burst flash, constant/shiny mix.
2. The installation base is: L rod, straight rod, folding, and barrel type.
Effect of LED warning light_Effect in different scenes
1. Construction unit
On the road ...
|
|
Siemens APT Relays – The difference between solid state relays and intermediate relays
First, the solid-state relay has no contacts and coils in the structure, which can be opened and closed at a high frequency and will not produce sparks, and has a long service life;
Second, the intermediate relay is generally only used for the control loop, and cannot work with load, and will make a "pop" sound when it is sucked in;
...
|
|
Siemens APT Relays – What should I pay attention to when selecting relays?
1. When selecting a relay, it is necessary to understand the load and type of its contact, because the contact method of the relay of the same model is different, with multiple groups of contacts and single group contacts. When selecting a relay, you can choose the type of contact.
2. And in the peach ...
|
|
Siemens APT relays – classified according to the protection characteristics of the relays
(1) Sealed relay: Relay with low leakage rate by welding or other methods to seal the contacts and coils in the cover and isolate them from the surrounding medium.
(2) Enclosed relay: A relay that is sealed (not sealed) with a cover to protect the contacts and coils. ...
|
|
What are the main problems with Siemens APT Relays – Solid State Relays?
When the solid state relay is open and there is voltage at the load end, there will be a certain leakage current at the output end, and care should be taken to prevent electric shock when using or designing. When the solid-state relay fails to be replaced, the original model or the product with the same technical parameters should be selected as far as possible, so as to match the original application line and ensure that the system ...
|
|
Siemens APT Relays – Selection Principles for High Voltage Relays
1. Electrical parameter matching: The rated voltage and current of the high-voltage relay need to match the circuit demand, too small will lead to the failure of the switch, too large will waste the cost.
2. Mechanical parameter adaptation: the external dimensions, pin arrangement and wiring mode of the high-voltage relay need to be adapted to the actual installation ring.
|
|
Introduction to the advantages and disadvantages of Siemens APT relays - solid state relays
merit
1. High life, high reliability: solid state relay has no mechanical parts, the contact function is completed by solid devices, because there are no moving parts, so it can work in a high impact and vibration environment.
|
|
Introduction to the features of Siemens APT DY2 miniature relay
Various specifications, with indicator light, with manual test button, with surge suppression loop and other functions
Coil control voltage DC6V-220V, AC6V-240V(50/60HZ)
The rail type is equipped with a variety of adapting sockets
LED indicator, DC is green, AC is red
Illuminating...
|
|
Siemens APT Relays – Common Causes of Failure of Solid State Relays
1. The reason for the frequent disconnection of the coil: whether the solid state relay is cleaned with ultrasonic, whether the coil is overvoltaged, etc., will cause the coil to be disconnected.
2. The reason for the insufficient power supply of the coil: First, it is necessary to confirm the voltage of the solid state relay coil. If the voltage supplied to the coil is lower than ...
|
|
Siemens APT Relays – How to Choose the Right Power Relay
1. Measure the resistance of the contact
Use the resistance level of the universal meter to measure the resistance of the normally closed contact and the moving point, and its resistance value should be 0, (the contact resistance value can be measured in a more accurate way within 100 milliohms); The resistance between the normally open contact and the moving point is infinite. From this, it can be distinguished which is a normally closed contact ...
|
|
Siemens APT - ALS series limit switch FAQ
1. What are the installation methods of ALS limit switches?
Usually the limit switch is divided into front of the board installation or board back installation, all of which are installed by screws.
2. What are the different modes of limit switch action?
According to the action mode of the limit switch head, it is divided into ...
|
|