Delixi electrical components circuit breaker introduction

Create Date: 2024-8-30 12:03:23|Source: Delixi

What is a Circuit Breaker? What is the function of a circuit breaker? How to choose the right circuit breaker in the work? The circuit breaker is what we often call an air switch. Just like a dam that controls the release of water, when the sluice gate is opened, the flow of water is continuous, and when the sluice gate is lowered, it blocks the flow of water.

                               Delixi electrical components circuit breaker introduction

The circuit breaker is the symbol QF in electricity, and the circuit breaker is the symbol circuit breaker The role of the circuit breaker is to actively block the circuit, protect the power line and the motor, and actively block the circuit when they present severe overload or short circuit and undervoltage to prevent the expansion of the accident. In addition, the circuit breaker has an arc extinguishing device, which can bring a load safety switch!

Air switch can be divided into frame circuit breaker, molded case circuit breaker, mini circuit breaker (also called mini circuit breaker) according to the structure, during which the mini circuit breaker is divided into type B, type C and type d, DZ47-63 represents the type of air switch, DZ stands for Delixi molded case circuit breaker, 47 represents the design code, -63 represents the maximum type of circuit breaker is 63A20/400V, indicating that the rated voltage of the circuit breaker is 230V or 400V.

4000A indicates that the limit breaking current of the air switch is 4000A, in other words, the maximum current that the air switch can accept. If the 4000A is exceeded, the air switch will break down immediately. C-type switches are commonly used in lighting circuits, and this type (C-type) air switch can accept about 5-10 current impulses. To put it simply, when the rated current through the air switch reaches 63A, the air switch will not trip immediately, but will pass through a When the instantaneous current of the air switch reaches 5-10 times of the rated current, that is, 63A*5, the air switch will trip immediately. The purpose of this design is to prevent certain devices from passing high currents when they are activated.

Type B air switch is generally used in transformer, which can accept about 2-3 times of current impact, and type D air switch is generally used for motor power-on, which can accept about 10-20 times of current shock.

For example, a 4kw three-phase asynchronous motor, the rated current is about 7.5A, and the starting current is about 4-7 times the rated current of the motor, which is about 52.5A. If you choose a circuit breaker, you can choose a D16 circuit breaker, which not only satisfies the requirements of starting instantaneous current, but also satisfies the requirements of passing the rated current.

More on that
Delixi inverter constant pressure variable frequency water supply system control problem Delixi inverter constant pressure variable frequency water supply system control problem

1. The pressure of Delixi inverter system is unstable and easy to vibrate? Answer: The pressure of the system is unstable, which may be due to the following reasons: A. There is a problem with the direction of the pressure of the pressure sensor acquisition system, and the pressure collection point is too close to the water outlet of the water pump, and the pressure of the pipeline is affected by the water outlet ...

Delixi inverter EM60 series model introduction Delixi inverter EM60 series model introduction

S1 (Single-phase 110V, 50/60HZ) CDI-EM60G0R75S1 0.75KW CDI-EM60G1R5S1 1.5KW S2 (Single Phase 220V, 50/60HZ) CDI-EM60G0R4S2 (without built-in brake unit) 0.4KW CDI-EM60G0R4S2B (Built-in ...

Parameters of Delixi inverter speed controller Parameters of Delixi inverter speed controller

(1) Gain Parameter: The share gain of the speed manipulator. If the gain is too large, it may cause speed fluctuations. (2) Integration time parameter: the integration time of the speed manipulator, that is, the change rate of the output signal of the manipulator under the deviation step signal. The shorter the integration moment ...

Delixi reduces the number of inverter maintenance times Delixi reduces the number of inverter maintenance times

Inverter is a very widely used equipment in the modern factory, this is a new type of equipment, the price is very noble, and the price of inverter repair is also very expensive, so in the process of using inverter, pay attention to the use of inverter, on the one hand, inverter, delay inverter ...

The reason for the existence of Delixi voltage regulator The reason for the existence of Delixi voltage regulator

In general, every electrical device or device is designed for a wide range of input voltages. Depending on the sensitivity, the operating scale of the device is limited to a specific value, for example, some devices can tolerate ±10% of the rated voltage, while others can tolerate ±5% or less. ...

Delixi uses three-phase regulators need precautions Delixi uses three-phase regulators need precautions

1. If the fuse is burned out, please approve the load equipment as soon as possible, make repairs in time, and restore power; 2. If you use a fixed amount of fuse, please use a regular line, and do not match it at will, so as not to cause ...

Choose the right inverter method - Delixi Choose the right inverter method - Delixi

The type of inverter is selected according to the type of production machinery, speed regulation range, static speed accuracy, and starting torque requirements, and it is most appropriate to decide which inverter is the most suitable to use. The so-called suitability is not only easy to use, but also economical, to meet the basic conditions and requirements of technology and production. ...

Delixi voltage regulator safety installation method Delixi voltage regulator safety installation method

In people's lives, voltage regulators are not short, but some people do not install voltage regulators correctly, which leads to great safety hazards in the use of voltage regulators. Here's how to properly install the regulator: ...

Inverter application skills - Delixi Inverter application skills - Delixi

1. Shielded wires should be used for signal lines and control lines, which is beneficial to avoid disturbance. When the line is long, for example the distance jumps 100m, the conductor cross-section should be enlarged. The signal line and the control line should not be placed in the same cable trench or tray with the power line, so as not to disturb each other, it is best to place it through the pipe, ...

Delixi inverter control motor problem Delixi inverter control motor problem

Question: Delixi inverter control motor contactor does not start when there is no action? Solution: First check the output status of the controller reflected by the controller panel, and you can compare the 7 units on the panel described in the controller description book.

Delixi low dropout linear regulator type Delixi low dropout linear regulator type

1.AC/DC the use of power supply Schematic diagram of the use of low-dropout linear regulators in AC/DC power supplies. In this circuit, the alternating current is stepped-down by the power transformer to obtain the AC low voltage, and then through the rectifier filter circuit to obtain the unstable DC voltage, and then through the low dropout linear voltage regulation.

Delixi inverter controller output problem analysis Delixi inverter controller output problem analysis

The output of Delixi inverter controller does not match the operating frequency, and the analog output of the inverter is abnormal? Solution: First, you should confirm what hardware is wrong. Make the controller enter the manual debugging state, and use the universal ...

Delixi solid state relay relative to AC contactor characteristics Delixi solid state relay relative to AC contactor characteristics

Delixi solid state relay and Delixi communication contactor are more used products, so what are the advantages of solid state relay relative to communication contactor, how should we choose when we can choose? 1. First of all, the solid ...

Delixi inverter application case Delixi inverter application case

The traditional textile printing and dyeing industry is a labor-intensive industry, and the degree of automation is not high. Most of the transmissions used are not speed regulation, and most of the occasions that need speed regulation are DC motors, such as warping machines, sizing machines and many printing and dyeing equipment.

Low dropout linear regulator parameters and advantages and disadvantages - Delixi Low dropout linear regulator parameters and advantages and disadvantages - Delixi

Grounding current, also become quiescent current, load regulation (the smaller this value, the stronger the LDO can press the load) linear regulation (the smaller, the less influence of the input voltage on the output voltage, the better the LDO function) power supply ratio (PSSR), reflecting the Delixi LDO to the interference signal ...

Delixi E180 universal inverter introduction Delixi E180 universal inverter introduction

Product Introduction With optimized open-loop vector control, V/F control, closed-loop vector control, stable function, function optimization, it is a high-function vector inverter, which can be widely used in speed control accuracy, torque echoing speed...

Delixi surge protector knowledge quiz Delixi surge protector knowledge quiz

Many people don't know what a surge is, surge is also known as a surge or lightning protection maintainer, the first is to maintain the household electrical equipment when it rains and thunders to avoid being damaged by lightning, and when the lightning strikes high-voltage electricity is drained to the ground through the surge maintainer, it will not directly hit the electrical equipment ...

Delixi CDRA soft starter features Delixi CDRA soft starter features

Delixi CDRA soft engine is a set of soft start, soft stop, light load, energy saving and multi-functional protection in one of the motor control equipment. This is a shock-free and smooth motor during the entire start-up process. According to the type, it can be divided into equipment type and comprehensive. ...

Transformer abnormal power-off treatment fault method - Delixi Transformer abnormal power-off treatment fault method - Delixi

First of all, when the transformer is faulty, we must cut off the power supply of the transformer through abnormal methods for the first time, and many major electrical fires and electric shocks are caused by the main gate is not closed. Now let's take a look at what to do. ...

The treatment method of leakage protector often tripping - Delixi The treatment method of leakage protector often tripping - Delixi

1. Trial delivery and commissioning method The first thing to find is the fault of the remaining current action maintainer itself. The detailed operation method is: first block the power supply, and then remove all the zero-sequence transformer load side leads of the remaining current action maintainer (the second and third level remaining current action maintainers will directly remove the outgoing ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours