Parameters of Delixi inverter speed controller

Create Date: 2024-8-30 12:03:23|Source: Delixi

(1) Gain Parameter: The share gain of the speed manipulator. If the gain is too large, it may cause speed fluctuations.

(2) Integration time parameter: the integration time of the speed manipulator, that is, the change rate of the output signal of the manipulator under the deviation step signal. The shorter the integration time, the faster the correction of successive deviation values, but if the integration time is too short, it will lead to unstable control.

                               Parameters of Delixi inverter speed controller

(3) Differential time parameter: The differential moment of the velocity manipulator is to increase the output of the manipulator when the deviation value changes. The longer the differential time, the faster the manipulator outputs as the deviation changes. The differential effect makes the manipulation more sensitive to perturbations.

(4) Acceleration compensation differential moment: During acceleration, in order to compensate for inertia, a given change in the differential is added to the output of the velocity manipulator.

(5) Slip gain: The slip gain of the motor slip compensation control. Indicates complete slippage compensation, and 0% indicates zero slip compensation.

More on that
Damage and repair of internal electronic components of the inverter - Delixi Damage and repair of internal electronic components of the inverter - Delixi

1. Repair the damage of the inverter rectifier block The damage of the inverter rectifier bridge is also one of the common faults of the inverter, the inverter rectifier block produced in the early stage is mainly diode rectification, and now some rectifier blocks adopt the thyristor rectification method (voltage regulation and frequency modulation inverter). Middle...

Delixi inverter EM60 series model introduction Delixi inverter EM60 series model introduction

S1 (Single-phase 110V, 50/60HZ) CDI-EM60G0R75S1 0.75KW CDI-EM60G1R5S1 1.5KW S2 (Single Phase 220V, 50/60HZ) CDI-EM60G0R4S2 (without built-in brake unit) 0.4KW CDI-EM60G0R4S2B (Built-in ...

Brief description of power distribution appliances - Delixi Brief description of power distribution appliances - Delixi

1. The difference between power distribution appliances and control appliances Power distribution appliances: As the name suggests, it is a device that distributes electricity. Electricity, after coming out of the generator, is output by the bus, and can not be directly connected to the power equipment, and the demand is first output into the power station, which is the power distribution equipment, which is ...

The role of Delixi inverter on the motor The role of Delixi inverter on the motor

1. Frequency conversion speed regulation and energy saving. The inverter frequency conversion speed regulation and energy saving are mainly manifested in the application of fans and pumps. In order to ensure reliability in actual production, all kinds of production machinery are designed with power drives, and there is a certain margin. After turning down the motor rotation when there is no need to run at full speed in production, ...

Reducer troubleshooting method - Delixi Reducer troubleshooting method - Delixi

01 "O" ring spell In addition to the oil seal problem of the reducer itself, the robot manufacturer will also have an impact on the planning and installation of the reducer components, due to the sealing of the reducer, in addition to the oil seal, there are also O-rings. O-rings are a very common type of product sealing planning.

Attention to the wiring of the inverter ground wire - Delixi Attention to the wiring of the inverter ground wire - Delixi

1. Because there is leakage current in the inverter, in order to prevent electric shock, it is necessary for the inverter and the motor to be grounded. 2. Special grounding terminal for inverter grounding. To connect the grounding wire, use tinned crimp terminals. When tightening the screws, be careful not to break the screws. ...

Delixi time control switch KGL1 latitude and longitude technical parameters Delixi time control switch KGL1 latitude and longitude technical parameters

Delixi Electric KGL1 latitude and longitude time control switch is suitable for communication 50Hz operating voltage 380V and the following control circuits, Delixi time control switch, according to the local latitude and longitude, according to the season to change the automatic adjustment control time, as the timing of the implementation of components. Plugging in or out of all sorts of ...

The impact of inverter cable design on the life of the motor and cable - Delixi The impact of inverter cable design on the life of the motor and cable - Delixi

Reflected waves caused by a cable-motor impedance mismatch are prevalent in all AC VFD uses. The severity of the problem depends on the length of the cable, the rise time of the PWM (Pulse Width Modulation) carrier, the voltage of the VFD, and the magnitude of the impedance difference between the motor and the cable. ...

Noise characteristics of different switching regulator topologies - Delixi Noise characteristics of different switching regulator topologies - Delixi

Currently, there are many different switching regulator topologies. Some topologies are widely used, such as the classic buck converter, also known as the buck converter. However, there are also some lesser-known switch-mode DC-DC converters that include Zeta topologies. These topologies are divided into fundamental topologies ...

Delixi E series inverter common fault analysis Delixi E series inverter common fault analysis

Fault phenomenon, fault description, detailed description of troubleshooting measures No display at power-on, no display, no display Check whether the power wiring is correct; Check whether the 5V power supply is normal; Check whether the keyboard is in good contact with the control board; Check whether the control panel and keyboard are normal. If you use ...

Voltage regulator power selection and determination - Delixi Voltage regulator power selection and determination - Delixi

1. The output power of the voltage regulator is the maximum power Basically, most of the nominal power of household appliances refers to active power, and the so-called refrigerators, air conditioners and those water pumps used in the home, etc., most of them are also inductive loads that start instantaneous currents.

Classification of low-voltage electrical appliances - Delixi Classification of low-voltage electrical appliances - Delixi

1. Classified according to the operating voltage level Low-voltage electrical appliances: electrical appliances used to communicate circuits below 1200V and DC 1500V to play the role of on/off, protection, control or regulation. High-voltage electrical appliances: communication 1200V or more, DC 1500V or more. ...

Delixi inverter analog output fault analysis Delixi inverter analog output fault analysis

The analog output of Delixi inverter is abnormal, and the operating frequency of the inverter does not match the output of the controller? Solution(s): First, you should determine what hardware is going wrong. Make the controller enter the manual debugging situation, respectively...

Linear regulator and switching regulator concept - Delixi Linear regulator and switching regulator concept - Delixi

01. What is a linear voltage regulator? A linear regulator uses a transistor or FET that operates in its linear region to subtract the excess voltage from the input voltage applied to generate a conditioned output voltage. The so-called voltage drop voltage means that the voltage regulator maintains its output voltage at its ...

Causes and solutions for circuit breaker closing failure - Delixi circuit breaker Causes and solutions for circuit breaker closing failure - Delixi circuit breaker

1. Failure analysis. 1) Closing fuse, control fuse blowing or poor contact. 2) Poor contact of DC contactor or poor contact of control switch contact and auxiliary contact of circuit breaker. 3) The DC voltage is too low. 4) Closing and locking action. ...

Analysis of common problems of inverter - Delixi Analysis of common problems of inverter - Delixi

1. Why does the maintenance function of the inverter operate when the clutch is connected to the load? When the load is connected with a clutch, at the moment of connection, the motor changes sharply from the no-load condition to the area with a large slip rate, and the large current flowing through causes the inverter to trip over the current and cannot work. ...

Delixi inverter controller output problem analysis Delixi inverter controller output problem analysis

The output of Delixi inverter controller does not match the operating frequency, and the analog output of the inverter is abnormal? Solution: First, you should confirm what hardware is wrong. Make the controller enter the manual debugging state, and use the universal ...

AC contactor controls the forward and reverse rotation of the motor - Delixi AC contactor controls the forward and reverse rotation of the motor - Delixi

The forward rotation control of the asynchronous motor, the peers of the double contactor and the button are doing more, but is there anyone who will use an AC contactor to achieve the forward rotation control effect of the motor? Practical application: general bench drill, letter ...

The core difference between air disconnector and circuit breaker - Delixi The core difference between air disconnector and circuit breaker - Delixi

1. Although the air switch is a type of circuit breaker, it is a switch that will automatically disconnect as long as the current in the circuit exceeds the rated current. However, air switches are used in low-voltage distribution networks and electric traction systems, mostly on the low-voltage side. Widely used in the home, such as general household switches ...

Delixi CDI-EM60 series inverter Delixi CDI-EM60 series inverter

Delixi CDI-EM60 series inverter is a high-performance inverter, with the following characteristics and use: Characteristic: 1. It has good stability and reliability to ensure the stability and safety of the system operation. 2. High degree, wide range of speed control, ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top