Delixi E180 universal inverter introduction

Create Date: 2024-8-30 12:03:23|Source: Delixi

Product Introduction

                                  Delixi E180 universal inverter introduction

With optimized open-loop vector control, V/F control, closed-loop vector control, stable function, function optimization, it is a high-function vector inverter, which can be widely used in occasions with high requirements for speed control accuracy, torque echoing speed, and low-frequency output torque.

Technical features:

1. Superior function

The new vector control algorithm is selected, and the starting cabinet is large, the torque echo is fast, and the control accuracy is high, which further improves the operating power of the motor.

2. Powerful function and low cost

A large number of built-in functional modules include timers, virtual delay relays, operation modules, etc., which is equivalent to attaching a small PLC. It greatly reduces the customer's operating cost.

3. Easy to use

Built-in special machine function, through a function code, customers can easily realize the conversion of ordinary machine and special machine, convenient for customer selection, sensitive use.

4. Sensitive selection

15kW and below are equipped with built-in braking unit as standard, 18.5kW-22kW are optionally equipped with built-in braking unit, and 37KW and above are equipped with external braking unit. 11KW, 15KW, 200KW and above standard DC reactor, 18.5-55KW optional.

Occasions of use

Electric power, textile and chemical fiber, building materials, petroleum, chemical industry, metallurgy, municipal, papermaking, food and beverage, tobacco, etc

Options

E180-I/0 Expansion Card, E180-PG Encoder Expansion Card, E180-485 Communication Expansion Card, E180-DP Communication Expansion Card, E180-ZS Injection Molding Machine Expansion Card, E180-WSP Constant Pressure Water Supply Expansion Card.
More on that
An integral part of the electrical control system - Delixi An integral part of the electrical control system - Delixi

The electrical control system is generally called the secondary control loop of electrical equipment, different equipment has different control loops, and the control methods of high-voltage electrical equipment and low-voltage electrical equipment are also different. Specifically, an electrical control system refers to a combination of several electrical components that are used to complete the operation of a certain ...

Prevent damage to the inverter - Delixi inverter Prevent damage to the inverter - Delixi inverter

1. Check and tighten all terminals to prevent serious heating caused by loosening. 2. Conduct a comprehensive view of the input (including output) terminal, rectifier module, inverter module, DC capacitor and fast-melting devices, and the parameters ...

Delixi low-voltage AC contactor can not be suction reason Delixi low-voltage AC contactor can not be suction reason

AC contactor can sometimes be used for a long time can not be suction situation, although this is not a common problem of AC contactor, but AC contactor can not be suction will affect the efficiency of the operation and even damage the production equipment, with the equipment for too long, together without outstanding maintenance, are ...

Delixi indicator light failure and solutions Delixi indicator light failure and solutions

1. What should I do if the indicator light is on and when it is dark Generally, the reason for this situation is that the line contact is poor or the screws of the terminal are not tightened, we should check the condition of the line, connect the power cord and tighten the screws, and press the wire. ...

Delixi inverter common problems Delixi inverter common problems

1. The pressure of Delixi inverter system is unstable and simple vibration? Answer: The pressure of the system is unstable, which may be due to the following reasons: A. There is a problem with the orientation of the pressure of the pressure sensor collection system, the pressure collection point is too close to the water pump outlet, and the pipeline pressure is affected by the water outlet ...

The difference between Delixi LDO and DC-DC The difference between Delixi LDO and DC-DC

The so-called DC-DC is actually DC to DC voltage, of course, LDO is also a kind of DC-DC, and only LDO can only achieve step-down. The general DC-DC is mainly converted from DC to AC communication through the self-excited vibration circuit inside, so the external inductance and capacitor are required to achieve LC vibration (and LDO is only ...

Delixi spare parts replacement cycle Delixi spare parts replacement cycle

1. Cooling fan (2-3 years) As long as the inverter is in use, the cooling fan has always been running, so the cooling fan is generally a short-service life accessory, generally after the use of the cooling fan for 2-3 years, the bearings, balls, motors, etc. of the fan are seriously worn, and they need to be replaced.

General parameter setting skills of inverter - Delixi General parameter setting skills of inverter - Delixi

The setting menu of the inverter is divided into a first-level menu, a second-level menu, etc., and the menu is followed by parameters. If the inverter starts in standby (ready to run) condition, set the FUn-PSS-SP2 parameter to 15Hz, and then return to the standby state operation. In the practice setting ...

The reason why the Delixi switch socket is hot and hot The reason why the Delixi switch socket is hot and hot

1. The quality of the socket is low First of all, we should check whether the socket is a miscellaneous defective product, the copper clamping force in the defective socket is not enough, resulting in a poor connection between the socket and the plug, and the socket and plug will heat up after a long time of electrical use. Therefore, you must not buy cheap miscellaneous electric ...

The impact of inverter cable design on the life of the motor and cable - Delixi The impact of inverter cable design on the life of the motor and cable - Delixi

Reflected waves caused by a cable-motor impedance mismatch are prevalent in all AC VFD uses. The severity of the problem depends on the length of the cable, the rise time of the PWM (Pulse Width Modulation) carrier, the voltage of the VFD, and the magnitude of the impedance difference between the motor and the cable. ...

The reason for the whitening of the copper bar installed on the Delixi plastic case circuit breaker The reason for the whitening of the copper bar installed on the Delixi plastic case circuit breaker

In the project, because of the 630 A circuit breaker wiring bar in the 500 kVA box-type transformer, see the second circuit breaker and circuit breaker on the left in the figure. The temperature of this corresponding region is significantly higher than that of the other two corresponding regions, and the other two phases are also hot, and the copper bars of this phase have turned white. There is no induction Deli ...

Delixi inverter CDI-E180 series of introduction Delixi inverter CDI-E180 series of introduction

Product Introduction With optimized open-loop vector control, V/F control, closed-loop vector control, stable function, rich functions, it is a high-performance vector inverter, which can be widely used in speed control accuracy, torque echoing speed, ...

LDO low dropout linear regulator features - Delixi LDO low dropout linear regulator features - Delixi

Since it is used as a low dropout voltage regulator, the first feature is the extremely low input and output voltage difference, and secondly, it also has stable voltage output, low noise, small ripple, small size, and simple peripheral circuits. If an LDO regulator is used when planning the circuit, the general requirement is at least ...

Working principle of linear voltage regulator - Delixi Working principle of linear voltage regulator - Delixi

1. The structure and working principle of the linear voltage regulator: A commonly used low-voltage communication regulated power supply. It consists of three parts: transformer, inductor, and capacitor divider. 2. Single-phase voltage regulator: Single...

Delixi solid state relay relative to AC contactor characteristics Delixi solid state relay relative to AC contactor characteristics

Delixi solid state relay and Delixi communication contactor are more used products, so what are the advantages of solid state relay relative to communication contactor, how should we choose when we can choose? 1. First of all, the solid ...

The difference between an isolation switch and a circuit breaker The difference between an isolation switch and a circuit breaker

The circuit breaker has arc extinguishing equipment, so the circuit breaker can be operated with load, not only the load current, but also the fault (short circuit) current; The circuit breaker has a good package form, so simply observing the circuit breaker cannot intuitively determine whether it is in the closed or disconnected position. Isolate ...

Analysis of common problems of inverter - Delixi Analysis of common problems of inverter - Delixi

1. Why does the maintenance function of the inverter operate when the clutch is connected to the load? When the load is connected with a clutch, at the moment of connection, the motor changes sharply from the no-load condition to the area with a large slip rate, and the large current flowing through causes the inverter to trip over the current and cannot work. ...

Voltage regulator power selection and determination - Delixi Voltage regulator power selection and determination - Delixi

1. The output power of the voltage regulator is the maximum power Basically, most of the nominal power of household appliances refers to active power, and the so-called refrigerators, air conditioners and those water pumps used in the home, etc., most of them are also inductive loads that start instantaneous currents.

Delixi inverter built-in bypass soft starter CDRA-K3 Delixi inverter built-in bypass soft starter CDRA-K3

Delixi built-in bypass soft starter CDRA-K3 series is a set of soft start, soft parking and multi-functional protection in one of the motor control equipment. Realize a smooth starter motor without impact during the entire starting process. CDRA-K3 series has built-in bypass contactor and control power supply.

Delixi resistance quantifies the resistance exerted by the circuit to the flow of current Delixi resistance quantifies the resistance exerted by the circuit to the flow of current

We are able to compare the values of resistance and hose diameter (conductance vs. practical diameter). Regarding metal wires, this analogy works well. Small-diameter wires have a higher resistance than large-diameter wires made of the same metal. ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top