Inverter is a very widely used equipment in the modern factory, this is a new type of equipment, the price is very noble, and the price of inverter repair is also very expensive, so in the process of using inverter, pay attention to the use of inverter, on the one hand, it is inverter, delay the service life of inverter, on the other hand, it is also to reduce the frequency of inverter problems, reduce the cost of repair.
Physics is one of the primary aspects that affect the use of the inverter, according to a professional handicraft repairing the inverter according to his repair experience, most of the problems presented by the inverter are composed of the logistics of the inverter, which does not necessarily include the following three aspects:
1. The working temperature of the inverter. There are many electronic components inside the inverter, and some of them will change their functions according to the change of temperature, so that some temperatures will cause damage to the components. Therefore, the general working temperature of the inverter is better to be controlled within 0-55 degrees, and some slightly feverish objects should not be connected to the inverter.
2. The temperature has changed too much. If the temperature change is too large, then the inverter will be repaired by the condensation phenomenon of moisture inverter due to the temperature difference, and this phenomenon will be burned out briefly when the inverter is started, so in the place where the temperature difference between day and night is large, the use of the inverter to place some desiccant inside the inverter is very effective in removing condensation.
3. Corrosive gases. The internal electronic components of the inverter have poor erosion resistance than force, and they may not be exposed to aggressive liquids and solids in daily life, but aggressive gases will also constitute components, so it is necessary to avoid too much contact with aggressive gases to the inverter.
|
More on that
|
Delixi inverter E180 series technical features
1. Superior performance
The new vector control algorithm is adopted, and the starting cabinet is large, the torque response is fast, and the control accuracy is high, which further improves the operation efficiency of the motor.
2. Powerful function and low cost of use
Built-in large number of ...
|
|
Delixi product parameter unit VF and V difference
Voltage vf and v difference: The two have different meanings, vf on the battery indicates the feedback voltage, while v represents the capacity of the battery and is a unit of measurement of voltage. Lithium battery is a type of battery that uses lithium metal or lithium alloy as the positive/negative electrode material and uses a non-aqueous electrolyte solution.
...
|
|
Delixi anti-leakage is different from ordinary circuit breakers
Circuit breaker refers to a switchgear that can close, carry and break the current under normal circuit conditions, and can close, carry and break the current under abnormal circuit conditions within a specified time.
Circuit breakers can be used to distribute electrical energy, infrequently start asynchronous motors, and ...
|
|
Analysis of the quality of Delixi surge protector
Look at the quality of the surge protector, to see whether it can complete his basic specification, relative to the surge protector of the primary specification is whether the surge operating voltage can be constrained below the required value, the surge protector must discharge the lightning current when the mission is completed, this specification must be completely completed.
|
|
Servo motor failure and analysis - Delixi
1. Motor encoder alarm
1. The cause of the failure
(1) Wrong wiring;
(2) electromagnetic disturbance;
(3) Encoder hardware damage caused by mechanical vibration;
(4) Pollution caused by the on-site environment.
2 ...
|
|
Instrumentation overhaul method - Delixi
Contrasting method
The specific method is to let the problematic meter and the normal meter operate under the same conditions, and then detect the signals at some points and compare the two sets of signals measured, if there are differences, you can conclude that the fault is here. This method requires maintenance personnel to have considerable knowledge and skills.
|
|
Electrical appliances need voltage regulators for reasons
Typically, every electrical device or device is designed for a wide range of input voltages. Depending on the sensitivity, the operating scale of the device is constrained to a specific value, for example, some devices can tolerate ±10% of the additional voltage, while others can tolerate ±5% or less.
...
|
|
Delixi circuit breaker product characteristics classification
The function of Delixi circuit breaker is to make the circuit breaker internal electromagnetic tripping when the electrical equipment produces short circuit, overload, etc., resulting in the circuit breaker disconnecting the power supply, and maintaining the safety of electrical equipment and personnel.
When the electrical equipment is running, the circuit may produce abnormalities, which is the demand circuit breaker in the ...
|
|
Why is the operation of the inverter energy-efficient? - Delixi
The inverter lowers the output frequency to reduce the speed of the motor, taking the conditioning air volume as an example. By reducing the air volume, power consumption can be significantly reduced. Why is the operation of the inverter energy-efficient?
According to fluid mechanics, power = pressure× flow, flow ...
|
|
Fault analysis of commonly used voltage electrical appliances - Delixi
1. Voltage circuit breaker problem
The contact is overheated, you can smell the power distribution control cabinet, by checking that the moving contact is not completely inserted into the static contact, and the contact pressure is not enough, resulting in a decrease in the switching capacity, causing the contact to overheat. At this moment, it is necessary to adjust the operating organization so that the moving contact is completely inserted into the static contact ...
|
|
Delixi voltage regulator fault phenomenon
Delixi regulator output voltmeter keeps swinging back and forth, and sparks occur at the carbon brush, and the problem phenomenon and cause analysis
1. The contact pressure between the carbon brush and the coil plane is too small
2. The carbon brush is severely worn
Delixi voltage regulator has ...
|
|
Attention to the wiring of the inverter ground wire - Delixi
1. Because there is leakage current in the inverter, in order to prevent electric shock, it is necessary for the inverter and the motor to be grounded.
2. Special grounding terminal for inverter grounding. To connect the grounding wire, use tinned crimp terminals.
When tightening the screws, be careful not to break the screws. ...
|
|
Delixi inverter uses the keyboard to set the frequency step
Delixi inverter parameter check setting steps
Using the keyboard to set the frequency, we can use the keyboard number direct setting and the keyboard potentiometer setting two methods, and the control method can be selected by modifying the parameter P0.01.
...
|
|
The main factor affecting the poor heat of the instrument - Delixi
The operation of differential thermal analysis is simple, but in practical work, it is often found that the same sample is measured on different instruments, or different samples are measured on the same instrument, and the results of the differential thermal curve of industrial electrical appliances are different. The high temperature, shape, area, and size of the peaks will all change. ...
|
|
Delixi DZ47S wiring method
The general leakage circuit breaker is used to wire the principle of the upper and lower lines, as long as the phase line and the zero line can be distinguished, between, the zero line is marked with N on the right, and the incoming and outgoing lines are the same.
Delixi DZ47LE C40 ...
|
|
Delixi time control switch KGL1 latitude and longitude technical parameters
Delixi Electric KGL1 latitude and longitude time control switch is suitable for communication 50Hz operating voltage 380V and the following control circuits, Delixi time control switch, according to the local latitude and longitude, according to the season to change the automatic adjustment control time, as the timing of the implementation of components. Plugging in or out of all sorts of ...
|
|
The choice of Delixi miniature circuit breaker
(1) Type selection. Depending on the application, select different circuit breakers. Circuit breakers are generally divided into power distribution, lighting, motor maintenance, thyristor maintenance and leakage maintenance.
(2) Selection of the number of poles. It should be based on different installation environment conditions.
|
|
The difference between Delixi LDO and DC-DC
The so-called DC-DC is actually DC to DC voltage, of course, LDO is also a kind of DC-DC, and only LDO can only achieve step-down.
The general DC-DC is mainly converted from DC to AC communication through the self-excited vibration circuit inside, so the external inductance and capacitor are required to achieve LC vibration (and LDO is only ...
|
|
Methods for preventing breakdown of transformer insulation
1. Avoid water and air entering the transformer
(1) The transformer should be protected from water ingress and moisture during operation, and it is necessary to seal well the cap of the casing item, the top of the storage phase, the bushing pipe and its connecting pipes. If necessary, a leak detection test should be carried out, and if the insulation has been found to be damp, it should be adopted in time.
|
|
Delixi product installation, operation and maintenance instructions
Normal conditions of operation, installation, and transportation
1 Normal operating conditions
Appliances that meet the rules of this code should be able to operate under the following conditions.
Note: See Appendix B for the requirements of non-standard application conditions.
Non-standard ...
|
|