1.AC/DC the use of power supply
Schematic diagram of the use of low-dropout linear regulators in AC/DC power supplies. In this circuit, the alternating current is stepped-down by the power transformer to obtain the AC low voltage, and then the unstable DC voltage is obtained through the rectifier filter circuit, and then the stable DC power supply is obtained through the low-dropout linear regulator (LDO), and the AC sound in the power supply circuit is eliminated through the low-dropout linear regulator, and the ripple voltage is suppressed.
2. The application of battery or accumulator power supply circuit
The power supply voltage of the battery or accumulator will change within a certain range, the output voltage of the battery or accumulator will decrease with the increase of use time, after adding a low dropout linear regulator in the circuit, the DC work can not only be stable, but also when the battery or accumulator is close to the end of discharge, the DC output voltage remains stable, which increases the service life of the battery or accumulator.
3. The application in switching power supply circuits
Schematic diagram of the use of low-dropout linear regulators in switching power supply circuits. When the input DC voltage is much higher than the required DC operating voltage, a switching power supply circuit can be added before the low-dropout linear regulator circuit.
As we all know, the switching power supply has its unique advantages, such as high efficiency, the input voltage and the output voltage can be very different, etc., but it also has many disadvantages, especially when used in analog circuits, its shortcomings are more obvious, such as high output ripple voltage, large noise, poor voltage regulation, etc.
The low-dropout linear regulator can realize active filtering, remove interference, and greatly improve the accuracy of voltage regulation, in addition to the efficiency of the power supply system, there is no significant decrease in the efficiency of the power supply system.
4. The application of multiple mutually isolated power supply circuits
Low-dropout linear regulator (LDO) in some applications of multi-channel mutually isolated power supply circuits, such as communication equipment, is often powered by a power supply, but needs a plurality of small power supplies, and requires these small power supplies to isolate each other, that is, some of the small power supplies work, and other small power supplies need to be turned off in order to save power when they are not working, then a plurality of low-dropout linear regulator circuits can be used to carry out on-off and on-off control of the integrated circuit through the control terminal of the low-dropout linear regulator integrated circuit (5-pin integrated circuit).
|
More on that
|
Delixi inverter installation and wiring
1. The device of the inverter
1.1 The device environment requirements of the inverter
Ambient temperature - 10 °C - 40 °C;
Ambient humidity: The relative humidity does not exceed 90% (no condensation);
Other occasions requiring no direct sunlight, no corrosive gas and flammable gas, less dust, ...
|
|
What are the main series of Delixi switches
1. The aesthetic slab adopts frameless large buttons and fluorescent grid planning, giving people a comfortable texture experience. The large-pitch flat panel is simple and useful, and is available in four colours: Funky White, Champagne Gold, Starlight Silver and Midnight Black.
2 ...
|
|
Working principle and function of thermal relay
Thermal relay is a maintenance appliance used for overload maintenance of electric motors or other electrical equipment and electrical lines.
In the actual operation of the motor, if the machine is in abnormal condition or the circuit is abnormal, the motor will be overloaded, the motor ...
|
|
Delixi voltage regulator in the case of no load stable work?
Most modern LDOs and switching regulators operate reliably under no-load conditions, and some older power devices require a minimum load to ensure stability, because one of the electrodes that needs to be compensated is affected by the payload resistance. For example, the LM1117 requires a load current of at least 1.7 mA (most ...
|
|
Delixi solid state relay over AC contactor advantages
Delixi solid state relay and Delixi communication touch device are more used products, so what are the advantages of solid state relay compared to communication touch device, how should we choose when we can choose?
1. First of all, solid...
|
|
Low dropout linear regulator design power supply precautions - Delixi
1. Pay attention to the maximum value of output current: this is a very critical parameter, the current used exceeds the maximum output current of LDO, then the voltage is unstable, and the system will fail.
LDO limit parameters: The output current is considered according to the 2/3 criterion. The cost of the whole system ...
|
|
Delixi CDM molded case circuit breaker upgrade
The 6 series electronic molded case circuit breaker CDM6Ei was launched in 2017 with the addition of a 1600A shell frame; High through-off capacity, *** high Ics=65kA, to meet specific application occasions; Long-distance four-remote communication to complete intelligent connectivity; Support mobile APP communication and alarm non-tripping function; The maximum operating temperature of the product can be ...
|
|
A brief introduction to the characteristics of Delixi
1. Nominal value
A suitable approximation of a switchgear or component and equipment to mark or identify it.
2. Limiting value
The maximum or minimum promise of a quantity in the specification and specification.
3、 ...
|
|
Delixi inverter E102 series model
The S2 (single-phase 220V, 50/60HZ) comes standard with a built-in braking unit
CDI-E102G0R4S2B 0.4KW
CDI-E102G0R75S2B 0.75KW
CDI-E102G1R5S2B 1.5KW
CDI-E102G2R2S2B 2.2KW
...
|
|
Delixi circuit breaker operation failure
Operation failure is manifested by the dragging or misoperation of the circuit breaker. Because the most basic and important function of the high-voltage circuit breaker is to operate correctly and remove the fault of the power grid quickly. If the circuit breaker drags or malfunctions, it will pose a serious threat to the power grid, first of all: (1)) expand the scale of the incident, which may make the original ...
|
|
Delixi inverter harmonic control method principle analysis
1. Install AC reactor and DC reactor. When the inverter is used in the distribution transformer capacity is greater than 500kva, and the transformer capacity is greater than 10 times of the inverter capacity, an AC reactor is installed on the input side of the inverter. And when the output voltage of the distribution transformer is unbalanced and uneven in three phases ...
|
|
The core difference between air disconnector and circuit breaker - Delixi
1. Although the air switch is a type of circuit breaker, it is a switch that will automatically disconnect as long as the current in the circuit exceeds the rated current. However, air switches are used in low-voltage distribution networks and electric traction systems, mostly on the low-voltage side. Widely used in the home, such as general household switches ...
|
|
Delixi voltage regulator safety precautions
1. When the stabilized power supply is powered on, please do not disassemble the stabilized power supply or pull the input and output cables of the stabilized power supply at will to prevent electric shock or other electrical safety accidents.
2. The input and output connections of the regulated power supply must be reasonably arranged, ...
|
|
Working principle of linear voltage regulator - Delixi
1. The structure and working principle of the linear voltage regulator:
A commonly used low-voltage communication regulated power supply. It consists of three parts: transformer, inductor, and capacitor divider.
2. Single-phase voltage regulator:
Single...
|
|
Characteristics and parameters of industrial molded case circuit breaker - Delixi
1. Extra limit short-circuit breaking can be used for Icu
There are two types of breaking capacity targets for circuit breakers: additional limit short-circuit breaking capacity of 4U and additional operating short-circuit breaking capacity Ics. As a characteristic parameter, ICS is not only a brief consideration of the breaking ability of the circuit breaker, but also a breaking purpose.
|
|
The reason why the switch socket is hot - Delixi
1. The socket quality is low quality
First of all, we should check whether the socket is a miscellaneous and inferior product, the copper clamping force in the defective socket is not good, resulting in poor contact between the socket and the plug, and the socket and plug will heat up after a long time of electrical use. So be sure not to buy cheap miscellaneous ...
|
|
The difference between Delixi high-voltage circuit breaker and disconnector
The high-voltage circuit breaker (or high-voltage switch) is the primary power control equipment of the substation, which has arc extinguishing characteristics. When the system is in normal operation, it can intercept and connect the no-load and load currents of lines and various electrical equipment. When there is a problem in the system, it can quickly block the fault with the cooperation of relay maintenance.
|
|
Circuit breaker control loop to reduce damage method - Delixi
1 Anatomy of the causes
The various causes of the burning of the control loop components of the unmanned station are analyzed and classified as follows:
· When the personnel on duty operate, the precautions are not well grasped or the operation is improper;
· The organization does not lock and close the operation when it is not stored in energy, and the auxiliary contact of the switch cabinet ...
|
|
The meaning of type B, type C, type D in circuit breaker - Delixi
In the circuit breaker model, the requirement clearly indicates the type of tripper trip characteristic curve, which is a very important parameter in the circuit breaker model expression. The type of trip is generally indicated before the circuit breaker has additional housing current.
For example...
|
|
Is a circuit breaker an air switch? - Delixi
1. Circuit breaker refers to a switchgear that can turn on, carry and turn off the current under normal circuit conditions and turn on, carry and turn off the current under abnormal circuit conditions within a regular time.
According to the voltage of Delixi circuit breaker, there are high-voltage circuit breakers and low-voltage circuit breakers. Below 1kV ...
|
|