Delixi surge protector knowledge quiz

Create Date: 2024-8-30 12:03:23|Source: Delixi

Many people don't know what a surge is, surge is also known as power surge or lightning protection maintainer, the first is to maintain the household electrical equipment when it rains and thunders to avoid being damaged by lightning, when lightning strikes high-voltage electricity is drained to the ground through the surge maintainer, it will not directly hit the electrical equipment.

                              Delixi surge protector knowledge quiz

1. What is a surge maintainer?

Answer: Delixi's surge maintainer is an electronic component, when the circuit or communication line due to lightning strike high current suddenly peak current or overvoltage, can be instantaneously shunted to guide the high current voltage to the ground, so as to avoid surge damage to other equipment in the circuit.

2. What types of surge maintainers does Delixi have?

Answer: Delixi's current models are: DZ47Y surge, CDY1 surge has been discontinued, CDY6 surge and CDY9 surge

3. Why does Delixi surge have switch type and voltage limiting type, and what is the difference between the two?

Answer: Delixi's surge maintenance is a void discharge device, its lightning shock discharge capacity is large, its primary function is online discharge lightning energy; The voltage limiting surge maintainer is a zinc oxide varistor device, which has a small lightning energy discharge ability, but has a good overvoltage suppression ability, and its primary function is to confine the overvoltage online. Therefore, a switch-type surge maintainer is generally selected at the entrance of the building to release the lightning energy, and then the voltage-limiting surge maintainer is used in the post-stage circuit to restrain the high overvoltage that occurs in the post-line after the lightning energy is released in the previous stage. It is best to use T1 and T2 surge maintainers together to maximize the safety of the equipment in the distribution line.

4. Do I need to install a fuse and circuit breaker in front of the surge maintainer?

A: It can be installed or not. The purpose of the front fuse and circuit breaker is to avoid damage to the SPD and its line due to the power frequency freewheeling caused by lightning strikes, and it can also facilitate the repair and replacement of surges.

5. How many levels of Delixi surge are there, and what are the differences?

Answer: There are 2 levels of Delixi surge, which are T1 and T2 levels. The main differences are: the current capacity of the T1 surge maintainer is large, the discharge current is generally 100-200kA, and the voltage maintenance scale is 1800-2000kV; The discharge current of the T2 surge maintainer is 20-80kA, and the voltage maintenance level is less than 2500kV. The surge maintainer of T1 is mainly used for the discharge of lightning current, and the product curve is mainly 10/350μs wave type; The primary function of the T2 surge maintainer is to constrain the overcurrent voltage, and the product curve is an 8/20μs wavepattern.

More on that
Delixi takes you to understand the knowledge of resistance and resistivity Delixi takes you to understand the knowledge of resistance and resistivity

1. Resistance Indicates the magnitude of the conductor's resistance to the current. Conversion between units of resistance: 1KΩ=1000Ω R indicates the resistance, and the unit of resistance is: ohms (Ω) R=U/I U--- voltage (unit: volts V) I--- current (in ...

Methods for preventing breakdown of transformer insulation Methods for preventing breakdown of transformer insulation

1. Avoid water and air entering the transformer (1) The transformer should be protected from water ingress and moisture during operation, and it is necessary to seal well the cap of the casing item, the top of the storage phase, the bushing pipe and its connecting pipes. If necessary, a leak detection test should be carried out, and if the insulation has been found to be damp, it should be adopted in time.

Delixi uses three-phase regulators need precautions Delixi uses three-phase regulators need precautions

1. If the fuse is burned out, please approve the load equipment as soon as possible, make repairs in time, and restore power; 2. If you use a fixed amount of fuse, please use a regular line, and do not match it at will, so as not to cause ...

Delixi inverter start, stop how to wiring Delixi inverter start, stop how to wiring

The control of the inverter is nothing more than the basic logic of starting, aborting, forward rotation, rotation, and speed regulation, which basically requires that the level condition is useful, not the rising margin is useful, so the use of button switches to control the inverter is generally required to use the button in the form of self-protection ...

The material of the transformer - Delixi The material of the transformer - Delixi

In view of the regulation and control effect of the transformer in the power system, technicians need to choose the appropriate transformer finishing device operation, so as to play a normal effect. Winding data is the primary problem that transformer devices need to pay attention to, and the effects of devices of different materials are different. Concerning...

Delixi relay maintenance method Delixi relay maintenance method

Relay is a kind of electrical appliance that turns on or off the control circuit according to the change of external input signals, such as electrical quantity (voltage, current) or non-electrical quantity (heat, time, speed, etc.) to complete the control or maintenance mission.

Characteristics and parameters of industrial molded case circuit breaker - Delixi Characteristics and parameters of industrial molded case circuit breaker - Delixi

1. Extra limit short-circuit breaking can be used for Icu There are two types of breaking capacity targets for circuit breakers: additional limit short-circuit breaking capacity of 4U and additional operating short-circuit breaking capacity Ics. As a characteristic parameter, ICS is not only a brief consideration of the breaking ability of the circuit breaker, but also a breaking purpose.

Delixi inverter alarm parameter check method Delixi inverter alarm parameter check method

1. There is a problem with an inverter, it cannot operate and the LED shows "UV" (abbreviation of under voltage), which clarifies that the alarm in the book is under voltage of the DC bus. Because the power supply of the control loop of this type of inverter is not taken from the DC bus, but from the AC input through the transformer alone.

Introduction to the closed-loop control system of stepper motor Introduction to the closed-loop control system of stepper motor

1. The closed-loop control of the stepper motor was first in the form of encoder For stepper motors with low split ratio, a slotted disc and photoelectric sensor are usually used as a reaction encoder assembly, and the number of notches is equal to the number of steps taken by the motor per revolution, · About high resolution ...

Delixi fan and pump load frequency conversion selection Delixi fan and pump load frequency conversion selection

Delixi general fan, pump, the requirements for the inverter are simple, only the inverter capacity is equal to the motor capacity. Roots blowers, deep-water pumps, sediment pumps, and fast-changing musical fountains are available in a larger capacity. Lifting...

Delixi relay maintenance method Delixi relay maintenance method

Relay is a kind of electrical appliance that turns on or off the control circuit according to the change of external input signals, such as electrical voltage, current) or non-electrical quantity (heat, time, speed, etc.) to complete the control or maintenance mission.

The difference between Delixi air switch and leakage protection switch The difference between Delixi air switch and leakage protection switch

1. The role is different The air switch is a kind of circuit breaker that protects the "object", which can protect the safety of the entire household wiring and electrical appliances and other items to prevent the wire from being burned due to overheating. The leakage protection switch is a kind of circuit breaker that protects "people", which can be cut in time when leakage.

Delixi inverter fault maintenance Delixi inverter fault maintenance

Delixi inverter is a commonly used inverter, how to maintain in the event of failure?   Constant speed overcurrent: When the inverter is running at a constant speed, the output current exceeds the current value. Check whether the output circuit of the inverter is short-circuited. Check if the input voltage is low. Examine...

Type of use of AC regulated power supply Type of use of AC regulated power supply

(1) Ferromagnetic resonant communication regulator: a communication regulator composed of a full choke and a corresponding capacitor, with constant voltage voltammetry characteristics. The full type is a typical structure in the early stage of this type of regulator. It has simple structure, convenient production, wide allowable scale of input voltage, reliable operation, and overload energy.

Delixi DZ47S wiring method Delixi DZ47S wiring method

The general leakage circuit breaker is used to wire the principle of the upper and lower lines, as long as the phase line and the zero line can be distinguished, between, the zero line is marked with N on the right, and the incoming and outgoing lines are the same. Delixi DZ47LE C40 ...

Delixi anti-leakage is different from ordinary circuit breakers Delixi anti-leakage is different from ordinary circuit breakers

Circuit breaker refers to a switchgear that can close, carry and break the current under normal circuit conditions, and can close, carry and break the current under abnormal circuit conditions within a specified time. Circuit breakers can be used to distribute electrical energy, infrequently start asynchronous motors, and ...

Delixi inverter installation and wiring Delixi inverter installation and wiring

1. The device of the inverter 1.1 The device environment requirements of the inverter Ambient temperature - 10 °C - 40 °C; Ambient humidity: The relative humidity does not exceed 90% (no condensation); Other occasions requiring no direct sunlight, no corrosive gas and flammable gas, less dust, ...

Delixi reduces the number of inverter maintenance times Delixi reduces the number of inverter maintenance times

Inverter is a very widely used equipment in the modern factory, this is a new type of equipment, the price is very noble, and the price of inverter repair is also very expensive, so in the process of using inverter, pay attention to the use of inverter, on the one hand, inverter, delay inverter ...

Delixi CDF1 isolation switch introduction and the difference with the transfer switch Delixi CDF1 isolation switch introduction and the difference with the transfer switch

Delixi CDF1 load isolation switch, the product material is carefully selected, with the advantages of reliability and durability. At the same time, it is locked when the power is on, and it can only be turned on when the power is off, which effectively avoids the occurrence of electric shock accidents. The contacts are made of high-quality copper ...

Introduction to the type classification of voltage regulators - Delixi Introduction to the type classification of voltage regulators - Delixi

Voltage regulators have become an integral part of many appliances in household, industrial, and commercial systems. Earlier, manually operated or switchable regulators were used to raise or lower the input voltage to supply the output voltage within the desired range. This stabilizer is built with electromechanical relays as switchgear ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top