Delixi solid state relay and Delixi communication contactor are more used products, so what are the advantages of solid state relay relative to communication contactor, how should we choose when we can choose?
1. First of all, the solid state relay has a long life and strong reliability. SSR solid state relay corresponding to Delixi is CDG1 series, this solid state relay has no mechanical parts, there is a solid device end contact function, because there is no movement of parts, so it can work in a high impact, oscillating environment, due to the inherent characteristics of the components that make up the solid state relay, determines the long life of the solid state relay, high reliability. The communication contactor is to control the magnet through the coil to make the contact contact or disconnection, which will cause poor contact contact and other problems to burn the contactor after a long time.
2. The solid-state relay has good sensitivity, small control power and good electromagnetic compatibility. Solid state relays have a wide input voltage range, low drive power, and are compatible with most logic integrated circuits without the need for buffers or drivers.
3. Rapid conversion of solid-state relays. Due to the use of solids, the switching speed of solid-state relays can be from a few milliseconds to a few subtleties, and the conversion speed is very fast; The engagement of the communication contactor is controlled by a coil, so the conversion speed is in a few tenths of a second, which is slower than that of a solid state relay.
4. The electromagnetic interference of the solid-state relay is small. Since the solid state relay has no input coil, no touch arcing and no bounce, electromagnetic interference is reduced. Most AC output solid state relays are a zero-voltage switch that turns on at zero voltage and turns off at zero current, reducing abrupt aborts of the current waveform and thus reducing switching transient effects. The electromagnetic interference of the corresponding contactor is larger.
5. Solid state relays are smaller in size, while contactors are large in size. In some places where the space is relatively narrow, it may not be very convenient to install the contactor, so the solid state relay is required; However, the current of the solid state relay is generally not very large, while the contactor current can be very large.
6. There are various varieties of voltage conversion of solid-state relays, such as communication to communication, communication to DC, DC to DC, etc.; Contactors are not so sensitive and changeable.
|
More on that
|
The operating structure of the high-voltage circuit breaker - Delixi
1. Classification of switch operation organization
At present, the switches we encounter are generally divided into many types, such as oil-rich type (old model, now you can't see it at all), oil-poor type (some user stations also have it), SF6, vacuum, GIS (combined electrical appliances) and so on. These are all about the arc extinguishing medium of the switch. ...
|
|
Delixi voltage regulator power selection
1. The output power of Delixi voltage regulator is the maximum power
Basically, most of the nominal power of household appliances refers to active power, and the so-called refrigerators, air conditioners and those water pumps used in the home, etc., most of them are also rational loads that start instantaneous currents.
|
|
Delixi voltage regulator fault phenomenon
Delixi regulator output voltmeter keeps swinging back and forth, and sparks occur at the carbon brush, and the problem phenomenon and cause analysis
1. The contact pressure between the carbon brush and the coil plane is too small
2. The carbon brush is severely worn
Delixi voltage regulator has ...
|
|
Delixi E series inverter common fault analysis
Fault phenomenon, fault description, detailed description of troubleshooting measures
No display at power-on, no display, no display
Check whether the power wiring is correct; Check whether the 5V power supply is normal;
Check whether the keyboard is in good contact with the control board; Check whether the control panel and keyboard are normal.
If you use ...
|
|
Delixi inverter start, stop how to wiring
The control of the inverter is nothing more than the basic logic of starting, aborting, forward rotation, rotation, and speed regulation, which basically requires that the level condition is useful, not the rising margin is useful, so the use of button switches to control the inverter is generally required to use the button in the form of self-protection ...
|
|
Delixi inverter alarm parameter check method
1. There is a problem with a frequency converter, it cannot operate and the LED shows "UV" (abbreviation of under voltage), which clarifies that the alarm in the book is DC bus undervoltage. Since the control loop power supply of this type of inverter is not taken from the DC bus, but from the communication input through the transformer alone...
|
|
Delixi inverter selection
1. According to the load type, confirm the type of inverter: different load types, speed requirements and power size, and the need to choose different types of Delixi inverters. Therefore, it is necessary to understand in detail the type of motor load to be controlled to find the most suitable type.
...
|
|
Delixi fan and pump load frequency conversion selection
Delixi general fan, pump, the requirements for the inverter are simple, only the inverter capacity is equal to the motor capacity. Roots blowers, deep-water pumps, sediment pumps, and fast-changing musical fountains are available in a larger capacity.
Lifting...
|
|
Delixi spare parts replacement cycle description
1. Cooling fan (2-3 years)
As long as the inverter is in use, the cooling fan has always been running, so the cooling fan is generally the shortest service life of the accessories, generally after the use of the cooling fan for 2-3 years, the bearings, balls, motors, etc. of the fan are seriously worn, and they need to be replaced.
|
|
Delixi switching regulator basics
1. What is a switching regulator?
Switching regulator, English (regulatior), some people call it a regulator, a voltage regulator source. To achieve voltage regulation, it is necessary to control the system (negative feedback), from the theory of automatic control, we know that when the voltage rises, it is lowered by negative feedback, ...
|
|
Working principle of linear voltage regulator - Delixi
1. The structure and working principle of the linear voltage regulator:
A commonly used low-voltage communication regulated power supply. It consists of three parts: transformer, inductor, and capacitor divider.
2. Single-phase voltage regulator:
Single...
|
|
Delixi inverter installation and wiring
1. The environmental requirements of the inverter
Ambient temperature - 10 °C - 40 °C;
Ambient humidity: The relative humidity does not exceed 90% (no condensation);
Other occasions that require no direct sunlight, no corrosive gas and flammable gas, less dust, and an altitude of less than 1000m.
...
|
|
Delixi control transformer use precautions
Delixi control transformer is the most used type is BK, JBK, BKC and other types, these transformers use some precautions as follows!
1. Before purchasing, estimate the total capacity of the electrical appliances used, and choose a transformer with a certain capacity to ensure that it will not burn out when it starts instantaneously.
|
|
Leakage protector leakage cause - Delixi
1. Poor device
If the terminal posts of the leakage protector are not firmly connected during the installation, it will often lead to the heating and oxidation of the terminal post for a long time, so that the wire insulation layer will be scorched, and accompanied by the smell of ignition and rubber and plastic burning, forming an undervoltage of the line and tripping the leakage protector.
...
|
|
Delixi switching regulator basics
1. What is a switching regulator?
Switching voltage regulators, some people call it regulators, voltage regulator sources. Complete voltage regulation, is the demand control system (negative feedback), from the automatic control theory we know that when the voltage rises, it will be lowered through negative feedback, and when the voltage drops, it will be ...
|
|
The role of Delixi inverter
1. It can reduce the impact on the power grid, and there will be no problem of excessive peak-to-valley difference.
2. It can speed up the controllable function, and then speed up the slipping according to the needs of the user;
3. The abort mode of the motor and equipment is controllable, ...
|
|
Delixi voltage regulator working principle
In Delixi voltage regulator, the voltage correction from and under voltage conditions is performed through two basic operations, namely Oersted and step-down operation. These operations can be switched on and off manually or automatically by electronic circuits. Under voltage conditions, the voltage of the boost operation is increased to the rated voltage.
|
|
Delixi resistance quantifies the resistance exerted by the circuit to the flow of current
We are able to compare the values of resistance and hose diameter (conductance vs. practical diameter). Regarding metal wires, this analogy works well. Small-diameter wires have a higher resistance than large-diameter wires made of the same metal.
...
|
|
Linear and switching regulator features
The advantages of linear DC regulator are high stability, small ripple, high reliability, and easy to make a multi-output connected adjustable power supply. The disadvantages are large size, bulkiness, and relatively low power.
There are many kinds of this kind of regulated power supply, which can be divided into regulated power supply, stabilized current power supply and ...
|
|
The principle of circuit breaker jumping, closing and holding circuit - Delixi
During opening and closing operations, the remote opening and closing command is usually a high-level pulse of several hundred milliseconds. In order to prevent the pulse from becoming invalid before the end of the opening and closing operation, and to ensure that the opening and closing operation is completed, a holding circuit is added. Intuitively, it is to avoid tripping and closing, and the exit contact precedes the DL ...
|
|