1. Selection of detection diode

Point-contact germanium diodes are generally used for detection diodes, such as 2AP series. When selecting, the detection diode with high operating frequency, small reverse current and large forward current should be selected according to the specific requirements of the circuit. Although the principle of detection and rectification is the same, the purpose of rectification is only to obtain direct current, while detection is to remove the signal component (envelope) from the modulated wave. The detection circuit and the half-wave rectifier circuit are exactly the same. Because the detection is a high-frequency wave rectification, the junction capacitance of the diode must be small, so the point contact diode is selected. Most of the diodes that can be used for high-frequency detection can be used in limiting, clamping, switching, and modulation circuits.

Replacement of detection diodes

After the detection diode is damaged, if there is no replacement of the same type of diode, the diode with the same semiconductor data and the main parameters can be used to replace it. In amateur conditions, a germanium high-frequency transistor with a damaged PN junction can also be used instead.

                               Diode selection and substitution method - Schneider

2. Selection of rectifier diode

The rectifier diode is generally a planar silicon diode, which is used in the rectifier circuit of the CPPCC power supply.

When selecting a rectifier diode, the parameters such as the largest rectifier current, the largest reverse operating current, the cut-off frequency and the reverse recovery time should be considered.

Generally, the rectifier diode used in the series regulated power supply circuit does not have high requirements for the reverse recovery time of the cut-off frequency, as long as the rectifier diode with the highest rectifier current and the largest reverse operation current meet the requirements according to the requirements of the circuit.

The rectifier diode used in the rectifier circuit and pulse rectifier circuit of the switching regulated power supply should be selected with a rectifier diode with a high operating frequency and a short reverse recovery time or a fast recovery diode.

Replacement of rectifier diodes

After the rectifier diode is damaged, it can be replaced with the same type of rectifier diode or other types of rectifier diodes with parameters.

In general, a rectifier diode with a high withstand voltage (reverse voltage) can replace a rectifier diode with a low withstand voltage value, while a rectifier diode with a low withstand voltage value cannot replace a rectifier diode with a high withstand voltage value. A diode with a high rectifier current value can replace a diode with a low rectifier current value, while a diode with a low rectifier current value cannot replace a diode with a high rectifier current value.

3. Selection of voltage regulator diode

Zener diodes are generally used as voltage references in regulated power supplies or as maintenance diodes in overvoltage maintenance circuits.

The selected voltage regulator diode should meet the requirements of the main parameters in the circuit used. The stable voltage value of the Zener diode should be the same as the reference voltage value of the circuit used, and the maximum stable current of the Zener diode should be about 50% higher than the maximum load current of the used circuit.

Replacement of regulator diodes

When the Zener diode is damaged, it should be replaced with a Zener diode of the same type or a Zener diode with the same electrical parameters.

A high dissipation power Zener diode with the same stable voltage value can be used to replace a Zener diode with a low dissipation power, but a Zener diode with a low dissipation power cannot be used to replace a Zener diode with a high dissipation power. For example, a 0.5W, 6.2V Zener diode can be replaced with a 1W or 6.2V Zener diode.

4. Selection of switching diodes

The role of a switching diode is to use its unidirectional conductivity to make it an ideal electronic switch. In addition to meeting the requirements of general diodes and performance indicators, switching diodes also have outstanding high-frequency switching characteristics (short reverse recovery time), and are widely used in home appliances, computers, televisions, communication equipment, household audio, DVD players, instrumentation, control circuits, various high-frequency circuits and electronic equipment such as switching circuits, detection circuits, high-frequency pulse rectifier circuits, etc.

Switching diodes are divided into general switching diodes, high-speed switching diodes, ultra-high-speed switching diodes, low-power switching diodes, high-backvoltage switching diodes, silicon voltage switching diodes, etc. For medium-speed switching circuits and detector circuits, 2AK series general switching diodes can be selected. High-speed switching circuits are selected based on the main parameters of the circuit (e.g., forward current, high reverse voltage, reverse recovery time, etc.).

Switching diode substitution

When a switching diode is damaged, replace it with a switching diode of the same type or replace it with another type of switching diode with the same main parameters.

High-speed switching diodes can replace general switching diodes, and switching diodes with high reverse breakdown voltage can replace switching diodes with low reverse breakdown voltage.

5. Selection of varactor diode

When selecting varactor diodes, it should be considered whether the parameters such as its operating frequency, high reverse operating voltage, large forward current and zero bias junction capacitance meet the requirements of the circuit used.

Varactor diode substitution

When a varactor diode is damaged, it should be replaced with a varactor diode of the same type as the original or with another type of varactor diode with the same main parameters (especially the junction capacitance range should be the same or nearby).

More on that
Schneider PLC signal light meaning Schneider PLC signal light meaning

Take the Schneider PLC with model number TWDLCAA40DRF as an example: The first PWR: is the meaning of power supply; The second RUN: is the PLC operation indicator; Long dark: The application is not fulfilling; Shine: The controller is in a stay or a mistake in performance; Solid on: The controller is in operation ...

The contents of the daily inspection of Schneider inverters The contents of the daily inspection of Schneider inverters

1) Whether the ambient temperature is normal or not, it is required to be in the range of -10-+40 °C, and it is better to be about 25 °C. whether the humidity meets the requirements, and whether the ventilation and heat dissipation of doors and windows are outstanding; Whether the lower air inlet and upper air outlet of the inverter are dusty or blocked due to excessive dust. ...

Schneider maintains the UPS power supply to extend the service life Schneider maintains the UPS power supply to extend the service life

Take charge of the basic knowledge of UPS power supply, read the equipment manual attentively, clarify the meaning of various warning signals, warning codes, command lights, and the causes of occurrence and how to deal with them to understand the effects of various switches and buttons of the equipment. Understand the various operations in charge of UPS power supply, understand the connection connection, and understand the method of substitution ...

Troubleshooting methods in electrical circuit control - Schneider Troubleshooting methods in electrical circuit control - Schneider

The troubleshooting method of the electrical control line is not the same as a thousand people, and various methods can be used cooperatively, but do not copy the rigid set. In general, investigative research can help us to find out the problem. The experimental method can not only find out the fault phenomenon, but also find the fault location or fault circuit; Logic...

Frequency converter and PLC connection problems - Schneider Frequency converter and PLC connection problems - Schneider

When the inverter is used to form an automatic control system for control, in many cases, the PLC and the inverter are used together, and how to correctly connect the PLC and the inverter together has become the key to the success of the system. 1.PLC switch ...

Schneider's small PLC part model Schneider's small PLC part model

  Schneider has M100/M200 for small programmable controllers, and M340 and M580 for medium and large programmable controllers The compact M100 model is available in TM100C24RN, TM100C32RN, and TM100C40RN. Small M200 ...

Functions of input/output pins P0, P1, P2, P3 – Schneider Functions of input/output pins P0, P1, P2, P3 – Schneider

P0.0——P0. 7 : Port P0 is an 8-bit open-drain bidirectional I/O port. When visiting off-chip memory, it is time-shared for a low-8-bit address and an 8-bit bidirectional data bus. When EPROM is programmed, the instruction byte is input by P0, and when the program is verified, it outputs ...

Dynamic phase angle tuning of inverter motors – Schneider Dynamic phase angle tuning of inverter motors – Schneider

1. The control cabinet, the main engine, and the brake connection line are correct, and the voltage is correct; 2. Safety circuit, door lock circuit is normal, limit switch, speed change switch and close; 3. The connection cable from the encoder to the PG card must be reliable and accurate; ...

Precautions for the selection of Schneider foot switches Precautions for the selection of Schneider foot switches

The foot switch series is XPE, and it should be noted when selecting: 1) Raw materials: metal and plastic, which are used in heavy-duty, high-risk, light-duty, low-risk occasions. 2) Pedal: divided into single pedal and double pedal (type end plus D). 3) With or without maintenance cover ...

Schneider Electric has announced a partnership with RMSI Schneider Electric has announced a partnership with RMSI

Schneider Electric has named RMSI North America, an IT services company that provides geospatial and software solutions, as an ArcFM Specialty Partner. RMSI is well positioned to provide GIS solutions for utilities and telecommunications companies across the entire geospatial value chain...

Pay attention to the problem when using UPS power supply - Schneider Pay attention to the problem when using UPS power supply - Schneider

1. The parameters set in the host cannot be changed at will during use. In particular, the parameters of the battery pack will directly affect the service life. With the change of ambient temperature, the float charge voltage should be adjusted accordingly. Generally, 25 °C is the standard, and when the ambient temperature rises or falls by 1 °C, the float charge ...

Schneider Lexium ILA all-in-one AC servo Schneider Lexium ILA all-in-one AC servo

The Schneider Lexium integrated drive consists of an electric motor and a control circuit that announces the control signal via a fieldbus, pulse/direction interface or I/O interface (for internal motion tasks). High compactness: motor and control circuits ...

Introduction to Schneider inverter fault code and maintenance method Introduction to Schneider inverter fault code and maintenance method

1. If the fault code presented on the Schneider inverter is AnF, it means that the load of the inverter has slipped, that is, the speed of the encoder does not match the initial value. First of all, we need to check whether the parameters of the motor are stable and the size of the load, ...

The operation essentials of Schneider disconnectors The operation essentials of Schneider disconnectors

Schneider Barrier Features: First of all, Schneider Barrier Switch can be used to block the power supply, it can disconnect the live equipment from the high-voltage maintenance equipment, and it can also see a significant disconnection point on it. The second is that Schneider Barrier Switches are able to work with circuit breakers to reach the point where the operation of the system is changed.

Schneider drives copy replication parameters Schneider drives copy replication parameters

1. Copy and copy through the Chinese panel. Older inverters, if they support Chinese panels, such as ATV71, ATV61, etc., support VW3A1101 panels, they can use the proprietary 'open/save as' parameter on the panel to copy and copy, and the newer ATV610, ATV630, ATV930, ...

The energy-saving effect of using frequency converter for fan and pump loads The energy-saving effect of using frequency converter for fan and pump loads

Why is the use of inverter for fan and pump loads to save energy? According to the basic laws of fluid mechanics, it can be seen that the fan pump load is a typical square rotation load, and its main characteristics are: speed n and torque T and load ...

THE DIFFERENCE BETWEEN SCHNEIDER CIRCUIT BREAKER EASYPACT AND MASTERPACT THE DIFFERENCE BETWEEN SCHNEIDER CIRCUIT BREAKER EASYPACT AND MASTERPACT

First of all, both are low-voltage circuit breakers (below 1000V) Let's start with Schneider Masterpact, which is a structural circuit breaker. The current rating of the structure varies from 800A ---- 6300A. The Masterpact series is divided into M series and MT series. The M series has been on the market since 1986 and was screened and delisted in 2002.

Steps for wiring and installation of rotary encoders – Schneider Steps for wiring and installation of rotary encoders – Schneider

Rotary encoder to roll the output pulse, through the counting equipment to know its position (PLC) we usually use incremental encoders, the incremental encoder output pulse signal can be directly input to the PLC, the high-speed counter of the PLC to count its pulse signal, in order to obtain the ...

Steps for configuring braking resistors in VFD – Schneider Steps for configuring braking resistors in VFD – Schneider

In the process of controlling the motor, the motor variable-frequency drive (VFD) may still have a certain kinetic energy when the motor rotates intermittently due to factors such as the moment of inertia of the motor, and the braking resistor is required to interrupt the motor. Here's a ...

The role of Schneider instrumentation in the air separation process The role of Schneider instrumentation in the air separation process

The appearance of the instrument plays a very important role in the air separation equipment and gas purification process, and it is indispensable for the adjustment of the air separation process and the detection of product quality. Because there are different types of on-line profiles for monitoring targets in different gaseous media at each stage of the ASU process, the ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top