RRKC Thermostat – The working principle and main features of the pop-up thermostat

Create Date: 2024-8-30 12:03:23|Source: RKC

How it works

The sudden jump thermostat is a kind of bimetal disc after constant temperature as a heat-sensitive reaction component, when the temperature of the main part of the product increases or decreases, the heat generated is transferred to the bimetal disc, and when the action temperature is set, it acts quickly, and the contact is disconnected or closed through the action of the mechanism, so as to achieve the purpose of turning on or disconnecting the circuit, so as to control the circuit. When the temperature rises (or falls) to the operating temperature, the disc of bimetallic material is used as a temperature-sensing element (using a cap to transfer heat), and the action is transmitted by the ceramic action rod to the elastic part - the moving contact holder. The moving contact and the fixed contact are riveted on the moving contact bracket and the horn respectively, and after the moving contact bracket is pushed by the action lever, the moving contact and the fixed contact are separated, so that the circuit is disconnected. When the temperature drops to the temperature of the dish-shaped bimetal, the bimetal instantly returns to its original shape, the pressure exerted on the action lever is eliminated, and the moving and fixed contacts are reconnected.

Key features:

The working temperature is fixed, the action is reliable and crisp, no arcing, long service life, reliable performance, no wireless interference, precise structure and complete functions.
RRKC Thermostat – The working principle and main features of the pop-up thermostat

More on that
How to set the parameters of RKC thermostat RH900 How to set the parameters of RKC thermostat RH900

1. Lower limit deviation alarm setting: press the SET key to select and display "SLP", the green display screen displays the value of the parameter, and select the shift, increment, and decrement keys to set or modify the parameter. This parameter indicates the difference between the alarm point and the master setpoint. 2. The upper limit deviation alarm is set ...

RLC thermostat – the wiring method of the thermostat RLC thermostat – the wiring method of the thermostat

Many household appliances and large-scale equipment products will be installed in the use of thermostats, thermostats will be combined with the change of ambient temperature in the switch when working physical deformation, which will produce some special effects, resulting in conduction or disconnection action, in order to achieve automatic ...

RKC thermostat - how to set the parameters of the thermostat? RKC thermostat - how to set the parameters of the thermostat?

1. Lower limit deviation alarm setting: press the SET key to select and display "SLP", the green display screen displays the value of the parameter, and select the shift, increment, and decrement keys to set or modify the parameter. This parameter indicates the difference between the alarm point and the master setpoint. 2. The upper limit deviation alarm is set ...

RKC Thermostat – Teach you how to choose a thermostat RKC Thermostat – Teach you how to choose a thermostat

(1) Size selection When replacing the thermostat, choose according to the original size; The newly added thermostat should take into account the overall coordination of the cabinet installed, too large to fit, too small to see the display, the same function of the thermostat, the price of large volume will be more expensive, small size may function expansion...

RRKC Thermostats – Considerations for Instrumentation Maintenance and Maintenance RRKC Thermostats – Considerations for Instrumentation Maintenance and Maintenance

There are many types of instrumentation and have a wide range of applications in many fields. Because of this, there are many problems with the failure of instruments in the process of use, so it is necessary to pay more attention to the repair and maintenance of instruments and meters, which can effectively improve the performance of instruments and meters, and can extend the performance of instruments and meters.

RKC Level Gauge – Precautions for the installation of float level gauges RKC Level Gauge – Precautions for the installation of float level gauges

1. The specific gravity of the liquid to be measured must be greater than the specific gravity of the float 2. The measured medium should not contain ferromagnetic impurities 3. The float level gauge should be installed in an unobstructed position when the float moves up and down 4. Magnets are not allowed to be close around the float level gauge, otherwise it will affect the float.

RLC Thermostat – Instructions for installation and use of pop-up thermostats RLC Thermostat – Instructions for installation and use of pop-up thermostats

1. Grounding method: It is connected to the grounding metal parts of the equipment through the metal cover of the thermostat. 2. The thermostat should work in the general indoor environment where the relative humidity of the air is not more than 90%, and there are no corrosive gases, flammable gases and conductive dust. 3. The thermostat adopts contact ...

Specifications and models of RKC thermostats Specifications and models of RKC thermostats

CH102 (48×48×100mm) CH402 (48×96×100mm) CH902 (96×96×100mm) 1. RH400 size: 48*96, depth 60, about 250g 1. Thermocouples: K, J, R, S, B, E, N, T, W5RE/W6RE, PL‖, U, L ...

RKC thermostat – the correct way to adjust the thermostat RKC thermostat – the correct way to adjust the thermostat

1. Set temperature: Press the SET button to set or view the temperature set point. Press the SET key digital tube character start flashing, indicating that the appearance has entered the setting state, press the △ key to increase the set value, press the ▽ key to decrease the set value, press and hold the △ key or ▽ key The data will change rapidly, press the SET key again The appearance will return ...

RKC Level Gauge – the correct way to use the float level gauge RKC Level Gauge – the correct way to use the float level gauge

(1) Before use, first check whether the level gauge is within the verification cycle, otherwise, it should be calibrated, and replaced in time if it is unqualified. (2) The sensor should be installed horizontally, and the length of the lower entry should meet the technical requirements. (3) The connection between the sensor and the explosion-proof junction box should be tightened and tightened.

What are the technical parameters of the rkc thermostat - the jump thermostat? What are the technical parameters of the rkc thermostat - the jump thermostat?

1. Electrical parameters: (1) VDE, CQC, UL, TüVAC250V 50-60Hz 10A (resistive load) (2) ULAC125V 50Hz 15A (resistive load) 2. Operating temperature range: -50-270°C (optional), temperature accuracy: ≥ ±2°C 3. Reset and action ...

RLC thermostat – what you should pay attention to when maintaining your temperature controller RLC thermostat – what you should pay attention to when maintaining your temperature controller

1. Do not wipe with acidic, alkaline and other corrosive liquids and water-containing rags when cleaning, so as not to damage the temperature controller and affect its normal use. 2. Do not decorate and cover the temperature controller. The thermostat has a built-in temperature sensor to sense the outside temperature. Therefore, Wen ...

RRKC Thermostat – The solution to the failure of the jump thermostat switch RRKC Thermostat – The solution to the failure of the jump thermostat switch

1. The cleanliness and finish of the contact surface have a great impact on the working state of the contact. When the appearance of the contact is rough or there is residue on the contact, it is easy to cause arcing and reduce the life of the contact. Therefore, the parts cleaning process should be improved to eliminate the residues; Add the process of residue selection, ...

RKG thermostat – the scope of application of underfloor heating thermostats RKG thermostat – the scope of application of underfloor heating thermostats

1) Separate households are independently heated, and floor heating is installed in small households, and boiler temperature control is applicable. 2) Separate households independent heating duplex building installation floor heating room temperature control. 3) Separate households for independent heating, large duplex villas are suitable for floor heating stratified temperature control. ...

Physical and chemical RK C thermostat - dry-type transformer thermostat shows fault handling methods Physical and chemical RK C thermostat - dry-type transformer thermostat shows fault handling methods

1. The dry-type transformer thermostat does not appear Cause of failure: (1) The power supply of the thermostat is not connected; (2) The fuse is blown out. Solution: (1) Turn on the power supply; (2) Replace the fuse. 2. The dry-type transformer thermostat shows that one or three phases are shining and showing "-OP-" ...

RKC Thermostat - How to Choose a Hot Spot Couple? RKC Thermostat - How to Choose a Hot Spot Couple?

The selection of thermocouples should be based on comprehensive considerations such as the scale of the operating temperature, the required accuracy, the atmosphere of the application, the performance of the measurement target, the response time and the economic benefits. 1. Selection of measurement accuracy and temperature measurement scale 1) The operating temperature is 1300-1800 °C, and the accuracy is required to be more accurate than ...

RRKC thermostat - how to set the parameters of the temperature control meter RRKC thermostat - how to set the parameters of the temperature control meter

1. Sensor type (this is based on the actual sensor used) 2. Upper and lower limit range (usually marked on the sensor) 3. Output range setting (current or voltage signal output) 4. Alarm value setting 5. Communication parameter setting (if no point 3 is set, ...)

Difference Between Thermocouple and RTD Difference Between Thermocouple and RTD

In temperature measurement, thermocouples and RTDs are both contact temperature measurements, and although they both measure the temperature of an object, their principles and characteristics are different. This article first introduces thermocouples, which are widely used in temperature measurement temperature control devices.

What are the precautions for the installation of the RKG thermostat? What are the precautions for the installation of the RKG thermostat?

1) For RTD input, 3 wires with low resistance and no difference should be used.   2) The input signal line should be far away from the power line of the instrument. Power supply and load lines to prevent noise disturbances.   3) The power cord of the instrument is generally disturbed by the power supply.   4) Instrument complement ...

RKC Thermostats – How to Choose a Thermocouple? RKC Thermostats – How to Choose a Thermocouple?

The selection of thermocouples should be based on comprehensive considerations such as the operating temperature range, the required accuracy, the operating atmosphere, the performance of the measured object, the response time and the economic benefits. 1. Selection of measurement accuracy and temperature measurement range 1) The operating temperature is 1300-1800°C, and the accuracy is required to be more accurate than ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top