Process introduction
High-purity gold wire (Au), copper wire (Cu) or aluminum wire (Al) is used to connect the Pad and Lead by soldering.
■ PAD is the external contact point of the circuit on the chip
■ Lead is the connection point on the Lead Frame.
W/B is the most critical part of the packaging process.
problem
1. Under ultra-high acceleration, it is easy to produce large deviations
Since the wires are all small segments of less than 4 mm, a very large acceleration is required to quickly reach the target speed. However, once the acceleration is too fast, the welding is prone to deviation, and it is difficult to ensure the yield of the product.
2. The instability of the motion control of the gantry mechanism
The motion accuracy of the gantry mechanism is affected by factors such as the accuracy of motor tuning, the synchronization accuracy of gantry movement and the accuracy of gantry zero-seeking repeatability, which may cause the accuracy of the final action to be insufficient.
3. Affected by cogging force, there is a follow-up error
Due to the structure of the stator of the linear motor, the linear motor will be affected by the cogging torque during the movement, resulting in periodic change following error.
4. It is necessary to maintain a constant pressure to solder the chip
solution
ultra-high-speed synchronous control,
Achieve a margin of error of only μ levels
Through Omron's programmable multi-axis motion controller CK series, the controller's high-performance servo algorithm and ultra-high scanning cycle (16-32K) are used to improve the response frequency of the servo cycle and achieve nano-level high-precision control. Finally, the control target of 20g in the XY axis and 160g in the Z axis was achieved, and the error range was stable to 1μm from 3 to 4ms.
Unique cross-decoupling control,
Ensure the motion accuracy of the gantry mechanism
Through Omron's programmable multi-axis motion controller CK series, the unique cross-decoupling control ensures the absolute level of the gantry in operation, and the zeroing mode specially designed for the gantry can also ensure the absolute level of the gantry after zeroing.
Using iterative self-learning algorithm,
Complete compensation of cogging forces
In general, generating a torque compensation table solves this problem. However, the measurement of cogging force is more difficult. Therefore, we use Omron's programmable multi-axis motion controller CK series with its own iterative learning control algorithm to automatically identify the cogging force, so as to complete the compensation of the cogging force and minimize the fluctuation of the following error.
Cascade algorithms are used to adjust the pressure in real time
Control system
■ Programmable multi-axis motion controller CK series
Deliver value
XY-Stage performance metrics
❶ XYZ acceleration: 20g, 20g, 160g
❷ Settling time: 2 to 4ms
❸ Maximum tracking error: 15μm
Gantry mechanism performance indicators
❶ XYZ acceleration: 5g, 5g, 10g
❷ Settling time: 3 to 5ms
❸ Maximum following error: 10μm
❹ Gantry two-axis deviation: 4μm
Management layer
■ In order to respond to the diversification of consumer product needs and the shortening of product life cycles, we have introduced highly creative motion control technology into the production site, realized the geometric improvement of equipment speed and accuracy, and created the industry's top competitiveness.
Management
■ Omron's programmable multi-axis motion controller, compatible with third-party products, allows customers to have more choices, such as choosing more economical motors and drives, which can improve the price advantage of equipment.
■ The positioning of the moving mechanism and the improvement of the speed and accuracy of the inspection are completely based on the optimization of the control system and program, without changing the mechanical structure and movement time, and the introduction time is faster and the cost is lower.
Engineer layer
■ The speed and accuracy of the equipment have been significantly improved, the stability time is 3 to 4ms, the error is controlled at 1μm, and the synchronization of gantry dual drive is perfectly guaranteed, and the acceleration reaches 5g.
■ Omron programmable multi-axis motion controller CK series, built-in iterative self-learning and other algorithms, can be directly called, simple debugging, short development cycle.
Article source: Omron Industrial Automation Information Account
|
More on that
|
Omron Relays – What are the main functions of relays?
(1) Expand the control range: for example, when the control signal of the multi-contact relay reaches a certain value, it can be changed, interrupted and connected to multiple circuits at the same time according to the different forms of the contact group.
(2) Amplification: For example, sensitive relays, intermediate relays, etc., with a very small ...
|
|
What are the common faults of Omron PLC?
1. CPU abnormality: When the CPU abnormality alarms, check the devices connected to the internal bus of the CPU unit. The specific method is to replace the units that may cause failures in turn, find out the faulty units, and deal with them accordingly.
2. Memory abnormality: When the memory is abnormal alarm, if it is a program ...
|
|
Analysis of common failures of Omron PLC
1. External equipment failure. Such faults come from external devices such as various sensors, switches, actuators, and loads. The failure of this part of the equipment will directly affect the control function of the system. This type of failure is usually caused by the quality and longevity of the equipment itself.
2. System failure ...
|
|
Introduction to the function of Omron PLC DIP switch
1. Address setting: The DIP switch can set the local address of the PLC for communication with other devices.
2. Communication parameter setting: The DIP switch can set the communication parameters of the PLC, including communication rate, data bit, check bit and stop bit, etc.
3. Input/Output ...
|
|
The reason why the ER light is always on after the Omron PLC is powered on
1. Fault phenomenon: The ERR light is always on when the PLC is powered on, and the PLC is not working.
2. Cause of failure:
(1) Poor use environment leads to oxidation and corrosion of internal MPU, memory, and even substrates.
(2) Due to electromagnetic interference, noise interference, static electricity, etc., the internal MPU ...
|
|
Omron PLC pre-maintenance preparation, maintenance procedures
(1) Prepare tools before overhaul;
(2) In order to ensure that the function of the component does not fail and the template is not damaged, it is necessary to use protective devices and carefully make anti-static preparations;
(3) Contact the dispatcher and operator before the overhaul, and hang the maintenance card at the place where the maintenance card is hung.
...
|
|
FAQs on Omron PLC
1.How to install the USB driver of CP1H?
The computer is connected to CP1H (powered on) through a USB cable, and the PC will automatically prompt to find the new hardware and prompt to install the driver.
2.The built-in USB port of CP1H can be used ...
|
|
Omron blood pressure monitor instructions and features
Omron sphygmomanometer uses oscillometric measurement method to measure blood pressure, with high accuracy, generally about ±5 Pa, and the measurement method is relatively simple. At the same time, there is a 21-time memory function, which can easily grasp the blood pressure change gauge.
|
|
How to connect Omron plc IP address?
1. The IP address of the computer is automatically obtained.
2. The computer is directly connected to the PLC network port.
3. Open the DirectEthernetUtility software. Software Setup Start - > All Programs - > OMRON - >Communications Middleware Utilities - > DirectE...
|
|
There are five classifications of Omron relays
The function of Omron automotive Omron relay is consistent with the function of ordinary relays, and the relay plays the role of a switch in the electrical automation industry, that is, by controlling the on/off of one circuit, so as to control the intermediate link of the next circuit on/off. Automotive relays are usually made of electromagnetic or solid...
|
|
Omron relays – the role of intermediate relays
1. Replace small contactors
The contacts of the intermediate relay have a certain load capacity, and when the load capacity is relatively small, it can be used to replace the use of small contactors, such as electric roller shutters and the control of some small household appliances. Such an advantage is that it can not only serve the purpose of control, but ...
|
|
The Omron mobile robot can move a payload of up to 250 kg
Omron's LD-250 can be used to transport large automotive parts, such as gearboxes and large quantities of packaging materials, which are normally handled by human workers using trolleys.
The robot is made of a sturdy metal enclosure that can withstand unexpected external shocks and requirements for more ...
|
|
Common causes and solutions of PLC failures in Omron operation
Fault phenomenon: The analog module CJ1W-DA041 outputs 4-20mA current for 4 channels, of which channels 2 and 3 are normal, and channels 1 and 4 have no current output.
Analyzing the circuit, the 4 current outputs use 4 manifold LT1490 for D/A conversion, and first measure the manifold LT on 1 and 4 channels.
|
|
Omron C series PLC models and their main meanings
Omron C series P-type machines have three types: basic, extended, and special-purpose, with a total of 4 types of CPU hosts, 6 types of I/O short-range expansion machines, and a variety of dedicated units.
1. The basic unit (also known as the host) has a CPU
Among them, C stands for the series code; (1) Table ...
|
|
Analysis of the location and cause of Omron PLC failure
1. External equipment failure. Such faults come from external devices such as various sensors, switches, actuators, and loads. The failure of this part of the equipment will directly affect the control function of the system. This type of failure is usually caused by the quality and longevity of the equipment itself.
2. System failure ...
|
|
Wiring method of Omron relays
Step 1: 13 and 14 of the contactor are the contacts of the contactor coil.
Step 2: When the voltage is added to 13 and 14, the intermediate relay acts.
Step 3: 9, 5 normally open, 9, 1 normally closed, after adding voltage, relay action, 9, 5 normally closed, 9, 1 normally open.
Clause...
|
|
Analysis of common Omron fault codes
1. C200H series PLC fault codes:
- E0001: Undefined program error
- E0002: Undefined instruction error
- E0003: Missing Program Error
- E0004: Data error
- E0005: Pointer error
- E0006: ...
|
|
The Omron CK3M/CK5M series has four major features to solve the problem of motion control
How can ultra-precision operations be realized in semiconductor and FPD manufacturing/inspection equipment, such as exposure machines, coating machines, dispensing machines, and wafer inspection equipment?
How to control special mechanical mechanisms, such as those with robotic mechanisms, in the manufacture of smart devices?
Machining Machine/Stamping Machine ...
|
|
Common problems and solutions in the maintenance process of Omron PLC
1. CPU abnormality:
When the CPU is abnormally alarmed, check all the devices connected to the internal bus of the CPU unit. The specific method is to replace the units that may have problems in turn, find out the problem units, and deal with them accordingly
2. Memory abnormality:
Memory anomaly ...
|
|
Common troubleshooting methods for Omron relays
First, the contact point is loosened and cracked
The contact point is the electrical contact part of the Omron relay to convert the load, and the contact point of some products is matched with each other by riveting pressure, and the key disadvantage is that the contact point is loose, the contact point is cracked or the error of the standard part is too large. This will jeopardize the relay ...
|
|