Common problems and solutions of Omron PLC
1. Omron PLC cannot be connected to the computer
There are two reasons why the PLC and the computer cannot be connected: hardware and software.
The hardware reasons are: the interface type does not match (such as USB, RS232, RS422, RS485, CAN, etc., both sides should be the same.) If you want to use the corresponding converter if you want to), ...
|
|
Omron United Traditional Pharmacy is continuing to increase the number of MMC health convenience stores
Omron Health Care and Traditional Pharmacy are continuing to build MMC health convenience stores to provide consumers with "one-stop health management and convenient consulting services at their doorstep", which has now been successfully extended to more scenarios such as enterprises, parks and communities.
Recently, with the epidemic prevention and control measures...
|
|
How Omron PLC works and what are the advantages
Omron PLC is a compact PLC with complete functions that provides highly additional machine control for industry-leading conveying and distribution control. It also has the ability to upgrade through a variety of advanced built-in boards, large program capacities and memory units for efficient software development in the Windows environment.
|
|
What are the mounting methods of Omron sensors?
The sensor can be fixed in two ways: PCB and disc mounting
1. PCB installation method
In general, the primary measurement signal of the PCB-mounted sensor is relatively small. The output terminal of the sensor adopts the way of pi pin or SMD, which can be performed according to the welding process of the general device in soldering.
|
|
Where did the cable with screws at the bottom of the Omron micro switch come from?
Different models of Omron micro switches may have different wiring methods. Generally speaking, the wire with screws at the bottom of the Omron micro switch is usually the contact used to connect the switch, which needs to be connected to an external circuit.
The wiring steps are as follows:
1. Confirm the bottom of the switch ...
|
|
Analysis of the causes of Omron S8 series switching power supply failures
1. Fault phenomenon: After powering on, the power supply does not respond.
2. Cause of failure:
(1) The input power supply voltage is insufficient and does not reach the specified range.
(2) The input power supply voltage is instantaneously impulsed, resulting in damage to the input components (such as fuses, rectifications, etc.) as shown in the figure: ...
|
|
Omron's new [Programmable Controller CP2E-ECT] was officially released
In December 2022, Omron Automation (China) Co., Ltd.'s new product [Programmable Controller CP2E-ECT] was officially released. The product is based on Omron's full research on the equipment needs of OEM customers in China, and is independently developed and produced by Omron China.
|
|
How to add SMC module to Omron plc
After adding the I/O module, you need to set it in the CX-PROGRAMMER program.
Find the IO table and unit settings, double-click to find the mainframe [0000], dot + sign, and then double-click 00 (if not set), 00 represents the module number closest to the CPU.
|
|
The main features of Omron PLC:
(1) Flexible structure
Regardless of the environmental limitations, the network can be built when there is electricity, and the number of access ports can be flexibly expanded, so that the resource utilization rate is high, and it is comparable to WLAN in terms of mobility.
(2) High transmission quality, fast speed and stable bandwidth
Can be very ...
|
|
There are five classifications of Omron relays
The function of Omron automotive Omron relay is consistent with the function of ordinary relays, and the relay plays the role of a switch in the electrical automation industry, that is, by controlling the on/off of one circuit, so as to control the intermediate link of the next circuit on/off. Automotive relays are usually made of electromagnetic or solid...
|
|
Omron Liang brings the latest seventh-generation FORPHEUS to the stage of the Expo
The 5th China International Import Expo (hereinafter referred to as the "Expo") will officially kick off on November 5. As a global expert in digital transformation in the field of automation, Omron will attend the appointment for the fifth time and bring new digital intelligence technologies and solutions to show its continuous focus on social development.
|
|
Omron's digital predictive maintenance prototype enables predictive maintenance without relying on skilled workers
With the development of society, manufacturing sites are facing new issues, such as the lack of skilled maintenance personnel, the aging of existing equipment, and the increase in equipment accident losses due to high value-added products. To this end, Omron relies on mature automation technology to electronically transform maintenance skills ...
|
|
How are Omron switch relays wired?
One. Before connecting, determine the voltage required for the proximity switch, and in the case of a 3-wire system, determine whether it is PP type or P type. The proximity switch is divided into 2-wire, 3-wire and 4-wire systems.
Two. Wire proximity switches are connected in series when connected to relays. i.e. the relay is connected to the proximity switch to give it ...
|
|
Omron Switches – What Aspects Are Needed for Switching Power Supply Design?
1. Wiring
The design requirements of wiring are very strict in the design of switching power supplies, and they must be done well to pass the test. If the designer does not handle the wiring work in the early stage of design, there will be great safety hazards in the future electricity consumption. So here I recommend you to buy a switching electric ...
|
|
Omron micro switch and model introduction
The micro switch is a contact mechanism with a small contact spacing and a quick action mechanism, with the specified stroke and the specified force for the switch action, covered with a shell, and a switch with a driving rod outside, because the contact spacing of the switch is relatively small, so it is called a micro switch, also known as a sensitive switch.
...
|
|
Omron PLC's maintenance procedures and equipment cleaning regulations
1. Maintenance procedures, regular testing and adjustment of equipment
(1) Check the connection of the terminal blocks in the PLC cabinet every six months or quarters, and reconnect the loose places in time if they are found;
(2) Re-measure the working voltage of the power supply to the main engine in the cabinet every month ...
|
|
The working principle and purpose of Omron relays
How it works
Add a certain voltage at both ends of the coil, a certain current will flow through the coil, thus producing an electromagnetic effect, and the armature will overcome the tensile force of the return spring under the action of electromagnetic force attraction and attract to the core, thereby driving the dynamic contact and static contact (normally open contact) of the armature ...
|
|
Omron Heater Status Monitor K7TM was officially released
In June 2022, Omron Automation (China) Co., Ltd.'s new product [Heater Status Monitor K7TM] was officially released. Without going to the site, through real-time monitoring of heater status, the aging trend of heater equipment that cannot be captured manually is clearly displayed, and predictive maintenance is realized!
In high temperatures ...
|
|
The solution to the E4 fault code on the Omron electronic blood pressure monitor
The E4 fault code usually appears on the display of the blood pressure monitor, indicating that the blood pressure monitor is poorly connected to the cuff or that the cuff is falling off. This failure can lead to inaccurate measurement results or even inability to complete the measurement.
Solution(s):
1. Check that the cuff is worn correctly and whether it is loose...
|
|
Omron - the application of intelligent logistics ring sorting line
Process introduction
The circular sorting line is the core equipment of the entire intelligent logistics system and the key link to improve the sorting efficiency. The equipment is mainly composed of four parts: trolley, camera system, loading area, and unloading area (also called grid mouth area):
problem
How to get a car ...
|