Omron's LD-250 can be used to transport large automotive parts, such as gearboxes and large quantities of packaging materials, which are normally handled by human workers using trolleys.
The robot is made of a sturdy metal casing that can withstand unexpected external shocks and more demanding duties. It also automates the transport of bulky materials such as gearboxes, seats or wiring harnesses in the automotive industry, as well as bulky packaging materials in the food and household goods industries. The robot will help more and more companies move workers from the material handling business to other higher, value-added tasks. Used in conjunction with Fleet Manager, which for the first time in the industry makes it possible to control multiple mobile robots with different payloads from a single system, it will contribute to a more flexible and optimized autonomous material handling system. Belt tops, courier systems, and adaptive material handling mechanisms can be easily accessed to create a solution that best meets the needs of the user. It also leverages the company's ability to customize mobile fleets with accessories for improved performance, such as HAPS*1, side lasers, and Acuity*2 visual positioning.
Get ready to give your material handling system a major boost. Omron's new LD-250 mobile robot has a payload capacity of 250kg and features an industrial-grade structure that is optimized for bulky items such as gearboxes, car seats, and large volumes of packaging materials.
Together with Omron's powerful fleet manager, which can manage fleets of up to 100 robots, the LD-250 helps manufacturers build more flexible and optimized autonomous material transportation systems.
Now it's time to increase the productivity and profitability of your high-mix production line with Omron's mobile robots.
|
More on that
|
Omron officially announced that it has become the official supplier of household health equipment for the Hangzhou Asian Games and the Asian Para Games.
Recently, Omron officially announced that it has become the official supplier of household health equipment for the Hangzhou Asian Games and the Asian Para Games.
The Hangzhou Asian Games will be held from September 23 to October 8, 2023, as the grandest event held in China this year.
|
|
The solution to the E4 fault code on the Omron electronic blood pressure monitor
The E4 fault code usually appears on the display of the blood pressure monitor, indicating that the blood pressure monitor is poorly connected to the cuff or that the cuff is falling off. This failure can lead to inaccurate measurement results or even inability to complete the measurement.
Solution(s):
1. Check that the cuff is worn correctly and whether it is loose...
|
|
【Omron industry case】Application of high-end pouch battery welding machine
Process introduction
In the middle process of the secondary battery, the battery welding machine first needs to quickly heat press the battery cells after winding/lamination to achieve cell compaction, and then ultrasonic welding of the positive and negative tabs of the battery cells.
problem
1. Pressure fluctuates greatly, causing ...
|
|
Omron PLC's maintenance procedures and equipment cleaning regulations
1. Maintenance procedures, regular testing and adjustment of equipment
(1) Check the connection of the terminal blocks in the PLC cabinet every six months or quarters, and reconnect the loose places in time if they are found;
(2) Re-measure the working voltage of the power supply to the main engine in the cabinet every month ...
|
|
Omron Liang brings the latest seventh-generation FORPHEUS to the stage of the Expo
The 5th China International Import Expo (hereinafter referred to as the "Expo") will officially kick off on November 5. As a global expert in digital transformation in the field of automation, Omron will attend the appointment for the fifth time and bring new digital intelligence technologies and solutions to show its continuous focus on social development.
|
|
Maintenance method of Omron PLC
1. Maintenance procedures, regular testing and adjustment of equipment
(1) Check the connection of the terminal blocks in the PLC cabinet every six months or quarters, and reconnect the loose places in time if they are found;
(2) Re-measure the working voltage of the power supply to the main engine in the cabinet every month ...
|
|
Fault repair of Omron blood pressure monitor
1. Mercury leakage
1. The cause of mercury leakage failure
Under normal circumstances, the sphygmomanometer will often leak mercury, which may eventually cause a certain error in the measurement value of the sphygmomanometer device. Then the cause of this malfunction is generally manifested as the blood ...
|
|
What are the mounting methods of Omron sensors?
The sensor can be fixed in two ways: PCB and disc mounting
1. PCB installation method
In general, the primary measurement signal of the PCB-mounted sensor is relatively small. The output terminal of the sensor adopts the way of pi pin or SMD, which can be performed according to the welding process of the general device in soldering.
|
|
How can Omron micro switches meet the market demand for smart locks?
Nowadays, the smart lock market has a wide variety of names, and it can't help but give people a sense of "random flowers gradually charming eyes". So, how to choose a cost-effective smart lock? In fact, in smart locks, micro switches can be said to occupy an important position. Microswitches ...
|
|
【Omron Industry Case】Application case of robot in cell stack welding
Equipment Overview
The stack welding machine is mainly used for the overlap welding of monocrystalline and polycrystalline cells in fully automatic crystalline silicon solar cell modules, and is suitable for series welding of small-size crystalline silicon solar cells.
|
|
Omron PLC's maintenance process and technical requirements
(1) When measuring voltage, it is necessary to use a digital voltmeter or a universal meter with an accuracy of 1%.
(2) The power supply rack and CPU motherboard can only be removed when the main power supply is cut off;
(3) Before the RAM module is removed from the CPU or plugged into the CPU, the power supply of the PC should be disconnected.
|
|
Fault maintenance methods commonly encountered in the operation of Omron PLC
(1) Failure of peripheral circuit components
This kind of failure is relatively common in PLC maintenance and usually occurs frequently after a certain period of work. If there is a component damage fault in the PLC control loop, the PLC control system will stop working immediately and automatically.
The input circuit is a PLC receiving switching quantity ...
|
|
Omron Relays – How relays work
1. Rated working voltage.
The voltage required by the coil for the relay to operate normally.
Depending on the model of the relay, it can be either AC voltage or DC voltage.
2. DC resistance.
The DC resistance of the coil in the relay can be used with a multimeter ...
|
|
Introduction to the application of Omron micro switches
About installation
When installing, disassembling, wiring, and maintaining and inspecting the Omron switching power switch, please try to carry out the switching power supply with the switching power supply OFF. Otherwise, there is a high risk of electric shock or burn damage.
About wiring work
Please do not switch on the power ...
|
|
Omron's first smart ventilator was officially launched on JD Health
On November 2, 2022, Omron's first intelligent ventilator, the fully automatic single-level ventilator HPS-A500, was officially launched at JD Health. The product integrates a number of patents and has a number of humanized functions, which will accelerate Omron's layout in the field of respiratory disease management.
Omron ...
|
|
What are the common fault phenomena of Omron relays?
One. Damage to glass insulators
Because the glass insulator of Omron relay is mainly made of metal prongs and glass sintering, it is easy to be damaged in the process of cleaning, overhaul, assembly, etc., such as bending of the pins, falling blocks, cracking, etc., resulting in Omron relays.
|
|
Common faults and maintenance methods of Omron micro switches
One
Omron micro switches in daily use, so we often encounter the phenomenon that the cover of the switch falls off, how does the cover of the switch fall off? The main reason for this is also to be sure that the cover of the switch falls off due to the excessive operation of the key switch.
|
|
Key Features of Omron PLC:
(1) Flexible structure
Regardless of the environmental limitations, the network can be built when there is electricity, and the number of access ports can be flexibly expanded, so that the resource utilization rate is high, and it is comparable to WLAN in terms of mobility.
(2) High transmission quality, fast speed and stable bandwidth
Can be very ...
|
|
Omron Switches – What Aspects Are Needed for Switching Power Supply Design?
1. Wiring
The design requirements of wiring are very strict in the design of switching power supplies, and they must be done well to pass the test. If the designer does not handle the wiring work in the early stage of design, there will be great safety hazards in the future electricity consumption. So here I recommend you to buy a switching electric ...
|
|
Omron and Inner Mongolia National University Pharmacy jointly built MMC Health Convenience Store
Recently, Omron and Inner Mongolia Guoda Pharmacy jointly built the first MMC health convenience store in Hohhot. The strong alliance in the field of health care aims to actively respond to the policy requirements of the national "new medical infrastructure", help the standardization of chronic disease services in offline stores, and make ...
|
|