1. Replace small contactors
The contacts of the intermediate relay have a certain load capacity, and when the load capacity is relatively small, it can be used to replace the use of small contactors, such as electric roller shutters and the control of some small household appliances. The advantage of this is that it can not only play the purpose of control, but also save space, so that the control part of the electrical appliance is more exquisite.
2. Increase the number of contacts
This is the most common use of intermediate relays, for example, when the contact of a contactor in a circuit control system needs to control multiple contactors or other components, but an intermediate relay is added to the line.
3. Increase contact capacity
We know that although the contact capacity of the intermediate relay is not very large, it also has a certain load capacity, and the current required for its drive is very small, so the contact capacity can be expanded with the intermediate relay. For example, it is generally not possible to directly use the output of inductive switches and transistors to control electrical components with large loads. Instead, an intermediate relay is used in the control line to control other loads through the intermediate relay to achieve the purpose of expanding the control capacity.
|
More on that
|
Omron switch - 9 tests and methods for switching power supplies
1. Repeated short-circuit test
◆ Test instructions
The output of the module is short-circuited in various input and output states, the module should be able to achieve protection or retraction, repeated short-circuits, and after troubleshooting, the module should be able to automatically resume normal operation.
◆ Test Method
a ...
|
|
Omron PLC cannot be connected to the computer, and the selected port is temporarily used by another program
Compile first, then click the PLC drop-down menu, select online work, pop up to prepare to connect to the PLC, the point is, if the PLC selected by the program is the same as the actual one, and the COM port is set correctly, there is no problem. After connecting, click on the PLC drop-down menu - > transfer - > from the PLC, and the program will be transferred to the computer. ...
|
|
What are the common faults of Omron PLC?
1. CPU abnormality: When the CPU abnormality alarms, check the devices connected to the internal bus of the CPU unit. The specific method is to replace the units that may cause failures in turn, find out the faulty units, and deal with them accordingly.
2. Memory abnormality: When the memory is abnormal alarm, if it is a program ...
|
|
Troubleshooting of Omron PLC
1. Check the switches in the battery or sensor area as well as in the problem area. Such as tool changers, tool changers and pallet changers. Look for potential alternatives or tools that may be defective through electronic prints.
2. Test the Omron PLC or internal control diagnosis of each output LED. Manual...
|
|
Key Features of Omron PLC:
(1) Flexible structure
Regardless of the environmental limitations, the network can be built when there is electricity, and the number of access ports can be flexibly expanded, so that the resource utilization rate is high, and it is comparable to WLAN in terms of mobility.
(2) High transmission quality, fast speed and stable bandwidth
Can be very ...
|
|
The disassembly sequence and method of Omron PLC equipment
(1) Shutdown for maintenance, more than two people must supervise the operation;
(2) Change the mode selector switch on the front panel of the CPU from "Run" to "Stop" position;
(3) Turn off the main power supply of PLC power supply, and then turn off other power supplies to the mold saka;
(4) ...
|
|
How to classify Omron signal relays?
1. Classified according to the principle of action
The electromagnetic relay drives the armature and the movable part to act through the suction generated by the current in the relay coil in the electromagnet and changes the working state of the contact system. Such as DC stepless relays, DC polarized relays, AC relays, binary differential relays...
|
|
Omron's first smart ventilator was officially launched on JD Health
On November 2, 2022, Omron's first intelligent ventilator, the fully automatic single-level ventilator HPS-A500, was officially launched at JD Health. The product integrates a number of patents and has a number of humanized functions, which will accelerate Omron's layout in the field of respiratory disease management.
Omron ...
|
|
Omron attended the 2022 P&G Electrical Automation Symposium
Recently, the 2022 P&G Electrical Automation Seminar held by Procter & Gamble (China) Co., Ltd. (hereinafter referred to as "P&G") was held in Guangzhou. Omron Automation (China) Co., Ltd. (hereinafter referred to as "Omron") was invited to attend the meeting and worked with the engineering, manufacturing, R&D and other departments of P&G factories on behalf of the ...
|
|
Introduction to the wiring steps of Omron switch relays
1. Before connecting, determine the voltage required for the proximity switch, and if it is a 3-wire system, determine whether it is PNP type or NPN type. The proximity switch is divided into 2-wire, 3-wire and 4-wire systems.
2. When the wire system proximity switch is connected with the relay, it is in series form. i.e. the relay is connected to the proximity switch ...
|
|
Analysis of the location and cause of Omron PLC failure
1. External equipment failure. Such faults come from external devices such as various sensors, switches, actuators, and loads. The failure of this part of the equipment will directly affect the control function of the system. This type of failure is usually caused by the quality and longevity of the equipment itself.
2. System failure ...
|
|
Omron blood pressure monitor instructions and features
Omron sphygmomanometer uses oscillometric measurement method to measure blood pressure, with high accuracy, generally about ±5 Pa, and the measurement method is relatively simple. At the same time, there is a 21-time memory function, which can easily grasp the blood pressure change gauge.
|
|
Omron PLC--CPM2A series product model
1. CPM2A-20CDR-D 20-point CPU unit, DC24V 12-point in, 8-point relay output, comes with RS232
2. CPM2A-20CDT-D 20-point CPU unit DC24V 12-point to 8-point transistor output with RS232
3. CPM2A-30CDR-D 30 points CPU unit DC24V 18 points ...
|
|
Omron PLC online modifies the procedure steps
1. Plug the data cable or network cable into the PLC socket and connect one end to the computer (Ethernet needs to set the computer IP and the IP of the PLC CPU to be in the same network segment)
2. Download the latest program from the PLC, or open the backup program, online program
3. Find the place in the program that needs to be modified.
|
|
Introduction to the function of Omron PLC DIP switch
1. Address setting: The DIP switch can set the local address of the PLC for communication with other devices.
2. Communication parameter setting: The DIP switch can set the communication parameters of the PLC, including communication rate, data bit, check bit and stop bit, etc.
3. Input/Output ...
|
|
Introduction to the classification of Omron relay switch contacts
1.A contacts
A contact is a contact in which the two contact terminals are separated (OFF) when the switch is not operated, and closed (ON) when the switch is operated. If you want to start the load by operating the switch, you can use the A contact. A circuit is a circuit that uses a contact without operating the switch (pressing ...
|
|
What's the deal with Omron PLC without output voltage?
1. The indicator light at the output of the PLC is on, indicating that the DO point of the PLC has been closed; 、
2. The DO point of PLC is equivalent to a dry contact switch, imagine that an on/off switch on a line is closed, if you measure the voltage on both sides of this switch, there will be no voltage, thinking that the switch itself ...
|
|
Omron PLC cannot connect to the computer
Method: If the computer has a 9-pin serial port, then you can make a wire. The wiring is as follows: computer PLC2 --------- 23 --------- 3 5 --------- 9 If you don't have it, you need a USB to serial port cable (you need to install a driver), and you can connect to PLC through the above wire ...
|
|
What are the main application areas of Omron relays?
In terms of application fields, Omron relays can be used in the following fields:
1) Home appliance market
Representative models: G5Q, G2RL, G5NB, G4A and other power relays
2) Medical market
Representative models: G6J-Y, G6S, G6K and other signal relays
...
|
|
Key points of maintenance of Omron relays
One. The surface of the Omron relay shell installed and used should be free of scratches, cracks and damage, and if there is serious damage, the relay should be replaced in time with intact and the same specification;
Two. In the process of Omron relay maintenance, it is necessary to check whether the contacts of the Omron relay are ...
|
|