Maintenance method of Omron PLC
1. Maintenance procedures, regular testing and adjustment of equipment
(1) Check the connection of the terminal blocks in the PLC cabinet every six months or quarters, and reconnect the loose places in time if they are found;
(2) Re-measure the working voltage of the power supply to the main engine in the cabinet every month ...
|
|
Omron | Sub-micron ultra-high-speed microfabrication
problem
Adapt to high-end manufacturing
With the diversification of consumer needs and the shortening of product cycles, various digital devices such as mobile devices are pursuing high performance, small size, and thin form factors, and the manufacturing process of semiconductor packaging and electronic components has also undergone tremendous development.
|
|
Common problems and solutions of Omron PLC
1. Omron PLC cannot be connected to the computer
There are two reasons why the PLC and the computer cannot be connected: hardware and software.
The hardware reasons are: the interface type does not match (such as USB, RS232, RS422, RS485, CAN, etc., both sides should be the same.) If you want to use the corresponding converter if you want to), ...
|
|
Nine main characteristics of Omron relays
1. Extra-small and lightweight
Omron relay has developed and manufactured a very small standard, leading the relay industry at home and abroad, and occupying a dominant position in the market.
2. Low driving current
The driving current is in the range of 6.5-16 mA, which achieves a low current, and in order to protect the environment, it is eco-efficient.
|
|
Introduction to the wiring steps of Omron switch relays
1. Before connecting, determine the voltage required for the proximity switch, and if it is a 3-wire system, determine whether it is PNP type or NPN type. The proximity switch is divided into 2-wire, 3-wire and 4-wire systems.
2. When the wire system proximity switch is connected with the relay, it is in series form. i.e. the relay is connected to the proximity switch ...
|
|
Omron Releases G7L-X PCB Power Relays with Higher Performance and Reliability
With the acceleration of global decarbonization, sustainable energy is increasingly becoming the focus of attention. At the same time, the sharp rise in global energy prices has further promoted the rapid growth of the residential photovoltaic market, and the market has begun to pay attention to the huge potential of photovoltaic power supply systems.
|
|
How Omron PLC works and what are the advantages
Omron PLC is a compact PLC with complete functions that provides highly additional machine control for industry-leading conveying and distribution control. It also has the ability to upgrade through a variety of advanced built-in boards, large program capacities and memory units for efficient software development in the Windows environment.
|
|
Omron's medical predictive electronic thermometer helps efficient epidemic prevention and control
Shanghai, China, July 7, 2022 – Measuring body temperature is an indispensable tool under the normalization of epidemic prevention and control. For hospitals and other places with a high concentration of people, how to improve the efficiency of temperature measurement, so as to do a better job in epidemic prevention in a more targeted manner, is a problem that must be solved.
Unique...
|
|
Omron PLC's maintenance process and technical requirements
(1) When measuring voltage, it is necessary to use a digital voltmeter or a universal meter with an accuracy of 1%.
(2) The power supply rack and CPU motherboard can only be removed when the main power supply is cut off;
(3) Before the RAM module is removed from the CPU or plugged into the CPU, the power supply of the PC should be disconnected.
|
|
Omron PLC--CPM1A-V1 series product model
1. CPM1A-10CDR-A-V1 10-point CPU unit AC100-220V, 6 points in, 4 points relay output
(1A is the model code; 10 means that the total number of input and output points is 10 points, specifically 6 points of input and 4 points of output; C means CPU unit; D stands for mixed type, that is, there is a loss ...
|
|
The solution to the E4 fault code on the Omron electronic blood pressure monitor
The E4 fault code usually appears on the display of the blood pressure monitor, indicating that the blood pressure monitor is poorly connected to the cuff or that the cuff is falling off. This failure can lead to inaccurate measurement results or even inability to complete the measurement.
Solution(s):
1. Check that the cuff is worn correctly and whether it is loose...
|
|
The technical cooperation exchange between Omron and Sanhua was held in Hangzhou
Recently, Omron Automation (China) Co., Ltd. (hereinafter referred to as "Omron") and Sanhua Holding Group Co., Ltd. (hereinafter referred to as "Sanhua") held a technical cooperation exchange meeting in Hangzhou. Nearly 100 senior leaders and technical experts from Omron, Sanhua and its subsidiaries attended the meeting.
...
|
|
Omron PLC cannot connect to the computer
Method: If the computer has a 9-pin serial port, then you can make a wire. The wiring is as follows: computer PLC2 --------- 23 --------- 3 5 --------- 9 If you don't have it, you need a USB to serial port cable (you need to install a driver), and you can connect to PLC through the above wire ...
|
|
Omron's digital × low-carbon solutions were unveiled in the industrial automation exhibition area
The 5th China International Import Expo opened in Shanghai. Based on the ever-evolving manufacturing concept "i-Automation!" The digital and low-carbon solutions created were presented to the audience on the heavyweight platform of the Expo.
At present, the curtain of global carbon neutrality has opened, and the ...
|
|
The application of Omron tension control in automobile motor winding
Process introduction
In recent years, the motor industry has shown a rapid upward trend, new products, new technologies are constantly updated and iterative, resulting in increasingly fierce competition between motor manufacturers, how to improve equipment performance, improve productivity, is the current motor manufacturers need to solve the problem.
...
|
|
Omron's digital predictive maintenance prototype enables predictive maintenance without relying on skilled workers
With the development of society, manufacturing sites are facing new issues, such as the lack of skilled maintenance personnel, the aging of existing equipment, and the increase in equipment accident losses due to high value-added products. To this end, Omron relies on mature automation technology to electronically transform maintenance skills ...
|
|
What are the characteristics of Omron 3G3JZ series inverter?
1. Standard configuration with RS485 interface, Modbus bus communication function;
2. At 3Hz, it can provide more than 150% torque output and start quickly;
3. The carrier frequency of 2-15KHz is adjustable, which can realize silent drive;
4. Equipped with simple energy-saving function;
5. Controlled ...
|
|
What are the functions of Omron relays?
1. Expand the scope of control. For example, when the control signal of a multi-contact relay reaches a certain value, it can be changed, interrupted, and connected to multiple circuits at the same time according to the different forms of contact groups.
2. Zoom in. For example, sensitive relays, intermediate relays, etc., with a very small control ...
|
|
Omron household oxygen concentrator failure and maintenance method
1/4 of the machine is not running, but the power indicator is on:
Reason: The compressor is overheated, so that the compressor turns on the overheating protection and stops automatically.
Exclusion method: If the machine runs for a long time without stopping, suddenly stops one day, and can run again after the machine is turned off and cooled, this is ...
|
|
Analysis of common failures of Omron PLC
1. External equipment failure. Such faults come from external devices such as various sensors, switches, actuators, and loads. The failure of this part of the equipment will directly affect the control function of the system. This type of failure is usually caused by the quality and longevity of the equipment itself.
2. System failure ...
|