1. Fault phenomenon: The ERR light is always on when the PLC is powered on, and the PLC is not working.
2. Cause of failure:
(1) Poor use environment leads to oxidation and corrosion of internal MPU, memory, and even substrates.
(2) Internal MPU and memory are damaged due to electromagnetic interference, noise interference, static electricity, etc.
3. Precautions:
(1) Pay attention to product protection on site to avoid water, oil or acidic liquid from being inside the product, resulting in corrosion and damage.
(2) The communication line and the signal line use shielded cables and are reliably connected.
(3) The communication line and signal line should be routed separately from the high-current power cable.
(4) The PLC should be installed in isolation from high-power or high-frequency equipment.
(5) AC220V power supply can be added with isolation transformer at the input end; For DC24V power supply, please make sure that the input power supply of the switching power supply is not co-ground with the power supply of the high-power equipment.
|
More on that
|
Omron electronic sphygmomanometer has added a new member - large-screen series of electronic sphygmomanometers
As the world's top electronic sphygmomanometer manufacturer, Omron electronic sphygmomanometer has been sold to 138 countries around the world and is still a world-renowned electronic sphygmomanometer brand.
With nearly 50 years of experience in the field of blood pressure management, Omron has always been committed to serving the health of Chinese residents.
|
|
Omron CP1 series PLC interrupt classification
1. I/O direct interrupt, which is the change of interrupt input from the built-in input unit on the CPU rack (0→1; 1→0).
2. Counting interrupt, the built-in input pulse of the CPU unit of the PLC is counted, and the interrupt is executed when the count reaches the set value.
...
|
|
Common causes and solutions of PLC failures in Omron operation
Fault phenomenon: The analog module CJ1W-DA041 outputs 4-20mA current for 4 channels, of which channels 2 and 3 are normal, and channels 1 and 4 have no current output.
Analyzing the circuit, the 4 current outputs use 4 manifold LT1490 for D/A conversion, and first measure the manifold LT on 1 and 4 channels.
|
|
Omron's digital predictive maintenance prototype enables predictive maintenance without relying on skilled workers
With the development of society, manufacturing sites are facing new issues, such as the lack of skilled maintenance personnel, the aging of existing equipment, and the increase in equipment accident losses due to high value-added products. To this end, Omron relies on mature automation technology to electronically transform maintenance skills ...
|
|
FAQs on Omron PLC
1.How to install the USB driver of CP1H?
The computer is connected to CP1H (powered on) through a USB cable, and the PC will automatically prompt to find the new hardware and prompt to install the driver.
2.The built-in USB port of CP1H can be used ...
|
|
How does Omron PLC input the rising/falling edge?
The first
1. First of all, we open the CX-P software, set the PLC model, enter the programming section, and prepare for programming.
2. Usually when we program, we are used to entering LD instruction programming, when we need to input the rising edge, we need to enter @LD0.00, you can.
3. Down...
|
|
Omron achieves its goal of increasing its share of the local healthcare market
Omron Asia Pacific Ltd. Philippines signed an agreement with Metro Drug Inc., a pharmaceutical sales and distribution company, to expand its distribution network for OMRON Healthcare Philippines' blood pressure monitors, nebulizers, thermometers, body composition monitors, and TENS massagers ...
|
|
How to choose Omron relays?
1. Select the rated working current of the electromagnetic relay coil: For the DC electromagnetic relay driven by transistors or integrated circuits, the rated working current of the coil (generally 2 times the suction current) should be within the output current range of the driving circuit.
2. Select electromagnetic relay contact ...
|
|
Omron Releases G7L-X PCB Power Relays with Higher Performance and Reliability
With the acceleration of global decarbonization, sustainable energy is increasingly becoming the focus of attention. At the same time, the sharp rise in global energy prices has further promoted the rapid growth of the residential photovoltaic market, and the market has begun to pay attention to the huge potential of photovoltaic power supply systems.
|
|
How to choose Omron micro switches?
1. Understand how the shape and scale of the switch affect other characteristics
The scale is important when choosing a micro switch. The switching scale is directly related to its characteristics, including current scale, stroke, and operating force. For example, the smallest microswitch on the market today measures 0.50" x 0. ...
|
|
Application of Omron Robotics in Medical Cartoner Loading System
Process introduction
In 2020, the new crown epidemic ravaged the world, and as of February 2022, the number of confirmed cases and deaths exceeded 400 million.
In the face of the continued ravages of the new coronavirus, the new crown epidemic ...
|
|
Omron switch - 9 tests and methods for switching power supplies
1. Repeated short-circuit test
◆ Test instructions
The output of the module is short-circuited in various input and output states, the module should be able to achieve protection or retraction, repeated short-circuits, and after troubleshooting, the module should be able to automatically resume normal operation.
◆ Test Method
a ...
|
|
Omron applications in semiconductor wire bonding equipment
Process introduction
High-purity gold wire (Au), copper wire (Cu) or aluminum wire (Al) is used to connect the Pad and Lead by soldering.
■ PAD is the external contact point of the circuit on the chip
■ Lead is the connection point on the Lead Frame.
W/B is the encapsulation process ...
|
|
What are some common troubleshooting methods for Omron?
(1) Failure of peripheral circuit components
This kind of failure is more common in PLC maintenance, and it is generally a frequent occurrence in failures after a certain period of work. In the PLC control loop, if there is a component damage fault, the PLC control system will immediately and automatically stop working. The input circuit is P...
|
|
How are Omron switch relays wired?
One. Before connecting, determine the voltage required for the proximity switch, and in the case of a 3-wire system, determine whether it is PP type or P type. The proximity switch is divided into 2-wire, 3-wire and 4-wire systems.
Two. Wire proximity switches are connected in series when connected to relays. i.e. the relay is connected to the proximity switch to give it ...
|
|
Omron MMC Health Convenience Store is once again stationed in Xi'an
On May 12, Omron Health Care (China) Co., Ltd. and Xi'an Yikang Pharmaceutical jointly built Xi'an Yikang Pharmaceutical Youyi West Road Store MMC Health Convenience Store (No. 105, 1st Floor, Life North District, Optical Machinery Institute, No. 121 Youyi West Road, Beilin District, Xi'an City) was officially opened and put into operation. The double ...
|
|
Key Features of Omron PLC:
(1) Flexible structure
Regardless of the environmental limitations, the network can be built when there is electricity, and the number of access ports can be flexibly expanded, so that the resource utilization rate is high, and it is comparable to WLAN in terms of mobility.
(2) High transmission quality, fast speed and stable bandwidth
Can be very ...
|
|
Routine maintenance methods of Omron relays
1. In the operation of Omron relay, if there is an abnormal sound or other abnormal conditions, the operation should be terminated first, and the skilled and professional repair staff should be notified to repair, and the operation can be resumed after the common fault is cleared.
2. In the whole process of maintenance, check the spring ...
|
|
Omron brought a variety of new blood pressure monitors to the Expo
Hypertension is the main risk factor for cardiovascular and cerebrovascular diseases, and is known as the "invisible killer of human health". The Lancet study shows that the number of hypertensive adults aged 30-79 has increased from 650 million to 1.28 billion in the past 30 years. In China, hypertension is also a cardiovascular disease.
|
|
What are the main items of Omron PLC overhaul?
1. Overhaul the power supply. It is possible to detect whether the voltage variation range is within the permissible ± 10% at the power terminal.
2. Working environment. Focus on checking whether the temperature, humidity, vibration, dust, interference, etc. meet the standard working environment.
3. Power supply for input and output. Available in the corresponding ...
|
|