1. External equipment failure. Such faults come from external devices such as various sensors, switches, actuators, and loads. The failure of this part of the equipment will directly affect the control function of the system. This type of failure is usually caused by the quality and longevity of the equipment itself.
2. System failure. This is a total failure that affects the operation of the system. System failures can be divided into fixed failures and occasional failures. If a failure occurs, it can be restarted to restore the system to normal, just like our computer system, which can be considered an accidental failure. Conversely, if the reboot cannot be recovered and the hardware or software needs to be replaced before the system can live normally, it can be considered a fixed fault, which is generally caused by the wrong system design or the long operation of the system.
3. Hardware failure. This type of fault mainly refers to the fault caused by the damage of the modules in the system, such as CPU, memory, power supply, I/O module, etc. (especially I/O module). This type of fault is generally more obvious, and the impact is also accompanied, they are mainly caused by improper use or long use, and the aging of components in the module.
4. Software failure. This type of failure is caused by a bug in the software itself. The main thing is that the software design is not well thought out. It will be triggered as soon as the conditions are met. In practical engineering applications, software errors are almost unavoidable due to the complexity and workload of software, which raises the question of software reliability.
|
More on that
|
How to choose Omron relays?
1. Select the rated working current of the electromagnetic relay coil: For the DC electromagnetic relay driven by transistors or integrated circuits, the rated working current of the coil (generally 2 times the suction current) should be within the output current range of the driving circuit.
2. Select electromagnetic relay contact ...
|
|
Omron Switches – What Aspects Are Needed for Switching Power Supply Design?
1. Wiring
The design requirements of wiring are very strict in the design of switching power supplies, and they must be done well to pass the test. If the designer does not handle the wiring work in the early stage of design, there will be great safety hazards in the future electricity consumption. So here I recommend you to buy a switching electric ...
|
|
How to input Omron PLC timer command?
1. After opening Omron PLC, you need to set LD X0 through ladder input and confirm.
2. After getting X000 in the next step, use the ladder diagram input to determine the timer instruction of out T0 K30.
3. At this time, the relevant settings will be completed, and you can directly ...
|
|
Omron PLC cannot connect to the computer
Method: If the computer has a 9-pin serial port, then you can make a wire. The wiring is as follows: computer PLC2 --------- 23 --------- 3 5 --------- 9 If you don't have it, you need a USB to serial port cable (you need to install a driver), and you can connect to PLC through the above wire ...
|
|
Powerful use of Omron color sensor-B5WC in industrial automation
With the rapid development of modern industrial production, automation has become an inevitable development trend, in the past production process, the human eye recognition color is not only too slow, but also requires high time cost and labor cost, has been unable to meet the needs of automated industrial production, so more and more ...
|
|
Omron PLC troubleshooting
1. Power check:
The first thing to analyze is the reliability of the power supply and ground of the Omron PLC. Visually inspect power and ground cables for damaged, corroded, or other suspicious links.
Power supplies can also be electrically tested. If there is AC power in the PLC processor, test ...
|
|
Omron brought a variety of new blood pressure monitors to the Expo
Hypertension is the main risk factor for cardiovascular and cerebrovascular diseases, and is known as the "invisible killer of human health". The Lancet study shows that the number of hypertensive adults aged 30-79 has increased from 650 million to 1.28 billion in the past 30 years. In China, hypertension is also a cardiovascular disease.
|
|
Omron micro switch and model introduction
The micro switch is a contact mechanism with a small contact spacing and a quick action mechanism, with the specified stroke and the specified force for the switch action, covered with a shell, and a switch with a driving rod outside, because the contact spacing of the switch is relatively small, so it is called a micro switch, also known as a sensitive switch.
...
|
|
The reason and solution for the ERC light of the DA08C output module of Omron plc
The ERC light of the DA08C output module indicates that the module is faulty, which may be caused by the incorrect electrical structure of the output terminal or the power supply overload.
Solution:
1. Check the electrical structure of the output terminal to ensure that the terminal coil is in correct contact;
2. Check the inside of the module ...
|
|
Introduction to Omron electronic thermometer and how to use it
Using an Omron electronic thermometer, which is displayed digitally and compared with a conventional thermometer, there is a small chance of error, generally no more than 0.1 degrees, so there is little need to worry about inaccuracies. Every time you use it, it's also very simple, just press the power switch ...
|
|
How to choose the right Omron switch?
1. Top button switch: suitable for occasions that require frequent pressing, such as video game consoles, calculators, etc.
2. Side button switch: suitable for occasions that need to be pressed on the side, such as mobile phones, remote controls, etc.
3. Knob switch: suitable for occasions that require rotary operation, ...
|
|
Omron PLC - PLC common fault maintenance and handling methods
1. The CPU is abnormal
When an abnormal CPU alarm, check all devices connected to the internal bus of the CPU unit. The specific method is to replace the units that may cause failures in turn, find out the faulty units, and deal with them accordingly.
2. The memory is abnormal
When the memory is abnormal ...
|
|
Omron PLC serial port communication protocol
There are two simpler ways to communicate:
1. Through serial port communication, CP1W-CIF01, that is, RS232 serial port option board is installed on the two CPUs respectively, and simple communication is achieved through PCLink protocol without programming;
2. Through network port communication, CP1H installs CP1W-CIF41 network port option board ...
|
|
The disassembly sequence and method of Omron PLC equipment
(1) Shutdown for maintenance, more than two people must supervise the operation;
(2) Change the mode selector switch on the front panel of the CPU from "Run" to "Stop" position;
(3) Turn off the main power supply of PLC power supply, and then turn off other power supplies to the mold saka;
(4) ...
|
|
Omron Relays – What are the main functions of relays?
(1) Expand the control range: for example, when the control signal of the multi-contact relay reaches a certain value, it can be changed, interrupted and connected to multiple circuits at the same time according to the different forms of the contact group.
(2) Amplification: For example, sensitive relays, intermediate relays, etc., with a very small ...
|
|
What are some common troubleshooting methods for Omron?
(1) Failure of peripheral circuit components
This kind of failure is more common in PLC maintenance, and it is generally a frequent occurrence in failures after a certain period of work. In the PLC control loop, if there is a component damage fault, the PLC control system will immediately and automatically stop working. The input circuit is P...
|
|
How to choose Omron micro switches?
1. Understand how the shape and scale of the switch affect other characteristics
The scale is important when choosing a micro switch. The switching scale is directly related to its characteristics, including current scale, stroke, and operating force. For example, the smallest microswitch on the market today measures 0.50" x 0. ...
|
|
Fault repair of Omron blood pressure monitor
1. Mercury leakage
1. The cause of mercury leakage failure
Under normal circumstances, the sphygmomanometer will often leak mercury, which may eventually cause a certain error in the measurement value of the sphygmomanometer device. Then the cause of this malfunction is generally manifested as the blood ...
|
|
Routine maintenance of Omron PLC
1. The electrical control cabinet installed with PLC should have a clean and dry environment. Moisture-absorbing dry materials should be placed inside, and the splashing of coolant and oil mist should be prevented.
2. Regardless of the system working or shutdown, the electrical cabinet door should always be closed, and the electrical components should be kept in a good state.
|
|
What are the advantages of Omron MOS FET relays?
1. The relay is small and still weldable.
The relays in SSOP/USOP packages feature directly exposed terminals for excellent visibility and easy installation.
2. Ultra-small and lightweight: In addition to SSOP and USOP, ultra-small packages contribute to the miniaturization of devices.
...
|
|