1. Check whether the piston pump is damaged and corroded, and replace it if so.
2. Check the fit of the plunger pair. Insert the end of the plunger into the plunger sleeve, tilt it about 60°, and if the plunger can slide slowly under its own action, it will fit well.
3. Check the tightness of the plunger pair. Hold the plunger sleeve in your hand and block the oil inlet above and on the sides of the plunger with two fingers.
4. Check whether the pressure reducing ring of the oil outlet valve is worn, there are steps or scars, and if so, it should be replaced.
5. Check the fit of the oil outlet valve pair. Plug the lower hole of the oil outlet valve with your finger, and gently press down the oil outlet valve with another finger, when the finger leaves the upper end of the oil outlet valve, it can automatically spring back to its original position, indicating that the oil outlet valve pair is well sealed, otherwise the oil valve pair should be replaced.
6. Check the tappet. The standard clearance between the injection pump body and the tappet body is 0-0.03mm
7. Check the gap between the plunger flange and the groove of the control sleeve, which should be 0.02-0.08mm, if it crosses 0.12mm, the control sleeve must be replaced.
|
More on that
|
The Rexroth Smart Handling Function Kit makes it easy for you to carry out your handling tasks
Want to carry out moving tasks with ease? Let the Bosch Rexroth Smart Handling Function Kit help you. Thoughtfully conceived and easy to set up, this mechatronic kit significantly reduces the time required to design handling solutions and takes your productivity to a whole new level.
Why...
|
|
Rexroth Hydraulic Pumps – Types of Hydraulic Pumps and Their Advantages and Disadvantages
There are three main types of hydraulic pumps: gear pumps, vane pumps and piston pumps.
1. Gear pump:
Advantages: small size, simple structure, less strict requirements for the cleanliness of the oil, and cheaper price;
Defects: However, the pump shaft is subject to unbalanced force, serious wear, and leakage.
|
|
Rexroth solenoid valve can not open the reason analysis and solutions
1) Coil problem
Use a voltmeter to measure the voltage across the coil. This should help you determine if the coil is working properly. You can also gently pull the coil to feel if there is a magnetic force acting on it. If it proves difficult to pull, the coil generates a magnetic field, which creates an excitation.
|
|
A test method for linear proportional control of CNC speed of Rexroth proportional valves
1. Remove the mold and cancel the express and trivial mold operation
2. Cancel the low-pressure trivia mold.
3. Close the safety door.
4. Adjust the CNC high-speed mold speed to the value of 0, and adjust the CNC high-speed mold opening speed and CNC low-speed mold opening speed to the value of 40.
5. Starter oil ...
|
|
How to adjust the DFR on the Rexroth A10VSO piston pump
Adjust the pressure adjustment screw of the relief valve to the loosest state.
The variable displacement piston pump is an A10VSO constant pressure variable displacement pump with flow limiter. Rexroth A10VSO variable pump is actually based on the constant pressure variable pump with a flow limiter (represented by the suffix S0169) ...
|
|
Rexroth | The plastics industry is at the forefront of sustainable drives
Guido Hettwer, Director of the Industrial Hydraulics Division, Bosch Rexroth (Photo: Bosch Rexroth AG)
Plastics machine builders have always been pioneers in new drive concepts that continuously improve performance and energy efficiency. For example, it was the first injection molding machine to open ...
|
|
A brief introduction and classification of Rexroth hydraulic pumps
Rexroth hydraulic pump is the power component of the hydraulic system, it refers to the oil pump in the hydraulic system, it is the hydraulic component that provides liquid for hydraulic transmission, and it is also a kind of pump. Its function is to convert the mechanical energy of the prime mover into the pressure energy of the liquid, that is, the hydraulic system is ...
|
|
Rexroth hydraulic pumps – precautions for the use of proportional valves
1. The power domain (working limit) of the proportional valve
For direct-acting electro-hydraulic proportional throttle valves, since the hydraulic force acting on the valve core is proportional to the flow rate and flow rate (pressure) through the valve port, when the working condition of the electro-hydraulic proportional throttle valve exceeds the product of its pressure drop and flow rate, that is, the power meter...
|
|
Rexroth hydraulic pump - how to use the piston pump
1. Preparation before starting: check the fastening of each component; Check the oil level of the oil tank, the height of the oil level is subject to the engraving line of the oil window on the oil tank, N46 in summer, N32 hydraulic oil in winter. High-pressure pumps and pumps above 140 should use the same type of anti-wear hydraulic oil. Check the pressure gauge range, liquid ...
|
|
Common problems and solutions of Rexroth hydraulic pumps
1. The pump does not absorb oil, the flow rate is not enough, the pump is empty, and the pump is damaged.
Damaged pumps, damaged skates or damaged ski and column ball joint seals; swash plate wear; wear of plungers and cylinder bores; failure of variable mechanisms; Wear of the oil distribution pan or wear of the oil distribution end face of the cylinder block; The LS valve of the pump is worn, the pressure is cut off...
|
|
Bosch Rexroth presents the EMC-HP series, a new member of the electric axis family
● Robust and precise thanks to the Planetary Screw Assembly (PLSA).
● Digital engineering: freely configurable with a range of different options
● Compact design for easy integration
Robust, precise and efficient: EMC-HP stands for press-fitting, riveting, positioning and testing.
|
|
Rexroth launches a new product, the IMScompact integrated measuring system
Space-saving design: The measuring sensor is fully integrated into the slide
Cost-effective position measurement system for a wide range of product sizes
From design to service, save time and money
Integrated absolute position measurement is used in a wide range of applications, due to its high water ...
|
|
Rexroth pressure reducing valve main types and technical parameters description
1. Pressure reducing and stabilizing valve
Main features: 1. Piston type with DN65 caliber or above. The life of the diaphragm is increased by more than 3 times; 2. Below DN50 caliber, the original diaphragm is replaced by a flat diaphragm of nylon reinforced rubber, which also improves the service life by more than 3 times. Applicable medium: water, air. Medium temperature ...
|
|
What to do when air enters the Rexroth hydraulic pump motor?
When Rexroth hydraulic pump motor has air, how do we correctly eliminate it so that the pump is not damaged, and then share with you the correct exhaust method:
(1) The oil has a certain compressibility, resulting in noise, vibration and crawling of moving parts in the system.
|
|
Common Fault Causes and Troubleshooting Methods of Hydraulic Pumps(1-8)
1. Cause of failure: the oil level of the hydraulic oil tank is too low;
Exclusion method: Add hydraulic oil.
2. Cause of failure: Hydraulic oil is not used according to the season;
Exclusion method: Usually suitable for 46# hydraulic oil (or 68#) without special replacement, consider using it when it is cold in the north in winter...
|
|
Rexroth A10VSO variable piston pump pressure flow adjustment steps
1. First, adjust the pressure adjusting screw of the relief valve to the loosest state, adjust the minimum flow limiter to the minimum state (the adjusting screw of the hydraulic cylinder in the upper part is adjusted to the loosest state), adjust the adjusting screw of the flow control valve to the tightest state, and connect a flowmeter in series after the relief valve;
2. Start-up fluid ...
|
|
Rexroth solenoid valve power conditions and application industry
Power condition
1) According to the type of power supply, AC and DC solenoid valves are selected respectively. In general, AC power is easily accessible;
2) AC220V.DC24V is preferred for voltage specifications;
3) The power supply voltage fluctuation is usually +%10%.-15% AC, and the power supply voltage fluctuation is usually +%10%.-15%.
|
|
Common faults and solutions of Rexroth piston pumps
Causes of failure: (1) The oil level of the hydraulic oil tank is too low;
Exclusion method: Add hydraulic oil
Causes of failure: (2) Hydraulic oil is not used according to the season;
Exclusion method: Usually suitable for 46# hydraulic oil (or 68#) without special replacement, consider using 32 ...
|
|
Rexroth Vane Pump PV7-1X/10-20RE01MC0-10 Debugging Precautions
Debugging considerations
exhaust
All PV7 vane pumps are self-priming.
Prior to commissioning, the pump must be emptied to prevent damage to the internal components.
When commissioning, it is advisable to fill the housing through a leak port. Pay attention to the filter accuracy class! This will improve the operation ...
|
|
Causes and analysis of the failure of Rexroth vane pumps
1) Rexroth vane pumps: Some users do not fill the pump with enough water before starting; It appears that the water has spilled out of the vent, but the air is completely discharged without turning the pump shaft, so that a little air remains in the inlet pipe or pump body.
2) Rexroth vane pump contact inlet pipe horizontal section of the counter-water flow ...
|
|