Generally, household appliances use a single-phase asynchronous motor, which relies on capacitance or resistance to split the phase. Motors are often in a short-term repetitive state (on/off) during operation, such as air conditioners, refrigerators, etc. This will inevitably bring a series of disadvantages such as frequent starting, high noise, short motor life, poor temperature stability and high energy consumption. The application of frequency conversion speed regulation technology not only brings the addition of functions and the improvement of functions to these household appliances, but also has obvious energy-saving and noise reduction effects, and at the same time makes the life of the whole machine significantly improved compared with traditional household appliances.
There are many ways to regulate the speed of asynchronous motors, such as pole change speed regulation, variable slip rate speed regulation and frequency conversion speed regulation. The first two types have high slip losses and low efficiency, and both have certain limitations on the characteristics of the motor. Frequency conversion speed regulation is to change the frequency of the stator power supply to change the synchronous frequency to complete the motor speed regulation. In the whole process of speed regulation, from high speed to low speed can adhere to a limited slip rate, so it has high efficiency, wide speed regulation range (10-100%) and advanced precision functions, and the power saving effect can reach 20-30%.
There are two methods of frequency conversion speed regulation: one is AC-DC-AC frequency conversion, which is suitable for high-speed and small-capacity motors; The second is alternating frequency. It is suitable for low-speed and large-capacity dragging system.
Inverter air conditioners can be divided into 3A and 3D inverter air conditioners according to the types of indoor fan motors, outdoor fans and compressors. Inverter air conditioners with indoor and outdoor fans and inverter compressors are all communication (AC) mode, which are generally called 3A inverter air conditioners; The inverter air conditioner with indoor and outdoor fans and inverter compressors in the form of three-phase brushless DC motor (DCBLM) is generally called 3D inverter air conditioner. The price of the latter is much higher than the former, and the material cost alone is nearly 300 yuan higher than that of the 3A inverter air conditioner of the same power, and the development is difficult, and the cooperation between the air conditioning system and the controller is more complex.
|
More on that
|
Delta's PLC programmable controller product list
1. Programmable manipulator AH series
Delta's AH series modular controllers provide automation system solutions for high-end applications. The AH series adopts a comprehensive modular design, and on the basis of Delta's research and development skills, it has developed ...
|
|
Debugging Delta's inverter method
In order to ensure the reliability of production, when Delta's inverter is planned to be equipped with power drive, in addition to meeting the power drive requirements, the remaining torque increases the consumption of active power. When using cost-effective Delta inverters to regulate the speed, if the flow requirements are reduced, by reducing the rotation of the pump or fan...
|
|
Selection of braking resistors for Delta inverters
1. The necessity of braking resistance
If the regenerative energy that occurs during deceleration and descent in the application is too large, there is a possibility that the voltage of the main circuit inside the inverter will rise, causing damage.
Because usually the inverter has a built-in overvoltage maintenance function, the main circuit overvoltage (O...
|
|
Precautions for the installation environment of the inverter - Delta inverter
(1) Ambient temperature:
The inverter is the same as other electronic equipment, and has certain requirements for the ambient temperature, which is generally "-10-+40°C". Because the inverter is a high-power electronic equipment, it is easy to be affected by the operating temperature, but in order to ensure the safety of the inverter...
|
|
Composition and function of Delta inverter
Delta inverter is a device that converts the power supply (50Hz or 60Hz) into AC power supply of various frequencies to realize the variable speed operation of the motor.
|
|
Delta linear motor driver ASDA-A2R series
In view of the rapid transformation of the industry, Delta has specially proposed a total linear motor solution, deploying various communication interfaces, extending the evolved model ASDA-A2R from ASDA-A2 as a linear horse driver, and deploying Delta's high-speed bus controller and axis card to form a complete linear motor ...
|
|
Brand inverter modifies the power method - Delta
What are the benefits of inverter power correction? Many brands of inverter power boards, driver boards, and motherboards can be universal, as long as the type, volume, and hardware are the same, and the desired power and voltage value can be obtained by correcting the manufacturer's parameters.
|
|
Delta's touch screen controls the inverter method
1. The touch screen is controlled by PLC inverter
1. Now the general control of the inverter needs to use PLC to communicate with the inverter, read the information of the inverter, and then the touch screen communicates with the PLC in order to complete the control of the inverter to start, stop, and monitor the operation of the inverter.
|
|
Delta's power supply series application considerations
(1) Considering that the power supply is inconsistent at the time of power-on, the load is short-circuited, and the rational load may present a reverse voltage, the output end of each power supply connected in series should be set up with two anti-parallel tubes, and the forward additional current of the two * tubes should not be less than the additional output current of the power supply, and the reverse breakdown voltage should not be less than ...
|
|
Precautions for long-term idle use of Delta inverter
If the inverter is to run the equipment again after being shelved for more than half a year, the probability of damage may be greatly increased due to many factors such as the placement environment, the service life of the inverter, and the load rate, and the failure usually presents the following problems:
...
|
|
Introduction and features of Delta PLC
Delta's programmable controllers, also known as Delta programmables, delta programmable controllers, delta programmable controllers, etc., are electronic devices specially designed by Delta for the industrial automation category to complete digital operations. Delta's PLC uses programmable memory to store execution logic inside it.
|
|
Delta's inverter product recommendation
Delta was established in 1971 to provide power supply and heat dissipation treatment programs for the world. Over the past 20 years, Delta's development in Chinese mainland has become increasingly deep-rooted, and its business operations cover development, production, sales and service. With innovative skills, we will continue to strengthen engineering research and development equipment and sophisticated testing ...
|
|
Principles of daily protection and maintenance of Delta inverters
1. Record the operation data and shortcomings of the Delta: The operation data of the Delta inverter and the motor should be recorded every day, including the output frequency, output current, output voltage, DC voltage inside the inverter, radiator temperature and other parameters, and compare them with reasonable data, so as to facilitate early detection of defects.
|
|
Precautions for initial installation of Delta inverters
Delta's inverters should be thoroughly inspected for the first time or after long-term installation. The items and methods of inspection are as follows:
1) Check whether the Delta inverter is damaged, whether the metal parts are rusty, and whether there is frost. If there is frost and condensation, it should be dried for 4 hours (60°C) or ...
|
|
Intelligent thermostat adjustment method - Delta
1. Set temperature: Press the SET button to set or view the temperature set point. Press the SET key digital tube character beginning flash, indicating that the appearance has entered the setting state, press the △ key to increase the set value, press the ▽ key to decrease the set value, press and hold the △ key or ▽ key The data will change rapidly, press the SET key again The appearance back ...
|
|
What are the series of Delta inverters?
1:VFD-EL,VFD-S,VFD-L,VFD-C200
Voltage 220V, 380V, power scale 100W-7.5kw
The above series are Delta's simple inverters, commonly known as economical inverters, which are used for small fans and pumps, conveyor belts on food and pharmaceutical machinery, etc., and are used for abbreviated ...
|
|
The key point to pay attention to when choosing a UPS power supply - Delta
(1) About the synchronous switching function. Now, in addition to the off-line UPS power supply with an additional output power of less than 500VA, the off-line UPS power supply with square wave output is still selected for conversion control without mains synchronization function, and all UPS power supplies with an output power of 1KVA and above are performing the conversion operation of mains power supply to inverter power supply.
|
|
Delta's inverter power-on debugging method
After the inverter is installed, disconnect the output of the inverter, use the diode file of the digital meter to measure the input and output of the inverter before the power is not turned on, ensure that there is no short circuit, and then turn on the working power supply of the inverter.
|
|
The inverter sets the characteristic parameters of the motor
1. Parameters to be set for the motor
When the inverter (hereafter referred to as the -VFD) is operating in the "vector control" (F0-03=1) mode, it is highly dependent on accurate motor parameters, which is one of the important differences from the "VF controlled" (F0-03=2) mode. In order for the VFD to have outstanding driving ...
|
|
Regular diagnosis and repair method of Delta servo motor
1. Common faults of motor heating up too high or smoke motor
Causes: 1. Excessive load; 2. Two-phase operation; 3. Blocked air duct; 4. The working temperature is too high; 5. Interphase or inter-turn short circuit fault of motor stator winding; 6. Motor stator winding grounding device; 7. The power supply voltage is too high or too low;
Overhaul...
|
|